Comparison of Time Domain and Spectral Domain Optical Coherence Tomography in Measurement of Macular Thickness in Macular Edema Secondary to Diabetic Retinopathy and Retinal Vein Occlusion

被引:20
作者
Hatef, Elham [1 ]
Khwaja, Afsheen [1 ]
Rentiya, Zubir [1 ]
Ibrahim, Mohamed [1 ]
Shulman, Matthew [1 ]
Turkcuoglu, Peykan [1 ]
Sepah, Yasir [1 ]
Wang, Jianmin [1 ]
Channa, Roomasa [1 ]
Bittencourt, Millena [1 ]
Akhtar, Abeer [1 ]
Heo, Jangwon [1 ]
Do, Diana V. [1 ]
Quan Dong Nguyen [1 ]
机构
[1] Johns Hopkins Univ Hosp, Wilmer Eye Inst, RIRRC, Baltimore, MD 21287 USA
关键词
REPRODUCIBILITY; DISEASE;
D O I
10.1155/2012/354783
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To evaluate macular thickness, agreement, and intraclass repeatability in three optical coherence tomography (OCT) devices: the time domain (TD) Stratus OCT and two spectral domain (SD) OCTs, Spectralis and Cirrus SD-OCT, in eyes with macular edema secondary to diabetic retinopathy (DR) and retinal vein occlusion (VO). Methods. In a prospective observational study at a university-based retina practice, retinal thickness tomography was performed simultaneously for fifty-eight patients (91 eyes) with DR and VO employing a time domain and two spectral domain OCTs. Agreement in macular measurements was assessed by constructing Bland-Altman plots. Intraclass repeatability was assessed by intraclass correlation coefficients (ICCs). Results. Based on the Bland-Altman plots for central macular thickness, there was low agreement between the measurements of Cirrus SD-OCT and Stratus OCT, Spectralis OCT and Stratus OCT, as well as Spectralis OCT and Cirrus SD-OCT among DR and RVO patients. All three devices demonstrated high intraclass repeatability, with ICC of 98% for Stratus OCT, 97% for Cirrus SD-OCT, and 100% for Spectralis OCT among DR patients. The ICC was 97% for Stratus OCT, 79% for Cirrus SD-OCT, and 91% for Spectralis OCT among RVO patients. Conclusion. There are low agreements among interdevice measurements. However, intraclass repeatability is high in both TD and SD-OCT devices.
引用
收藏
页数:9
相关论文
共 14 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
Davis MD, 2005, ARCH OPHTHALMOL-CHIC, V123, P1484
[3]   Enhanced visualization of macular pathology with the use of ultrahigh-resolution optical coherence tomography [J].
Drexler, W ;
Sattmarin, H ;
Hermann, B ;
Ko, TH ;
Stur, M ;
Unterhuber, A ;
Scholda, C ;
Findl, O ;
Wirtitsch, M ;
Fujimoto, JG ;
Fercher, AF .
ARCHIVES OF OPHTHALMOLOGY, 2003, 121 (05) :695-706
[4]   Evaluation of time domain and spectral domain optical coherence tomography in the measurement of diabetic macular edema [J].
Forooghian, Farzin ;
Cukras, Catherine ;
Meyerle, Catherine B. ;
Chew, Emily Y. ;
Wong, Wai T. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (10) :4290-4296
[5]   THE DEVELOPMENT OF PARAFOVEAL AND MID-PERIPHERAL HUMAN RETINA [J].
HENDRICKSON, A ;
DRUCKER, D .
BEHAVIOURAL BRAIN RESEARCH, 1992, 49 (01) :21-31
[6]   Optical coherence tomography to detect and manage retinal disease and glaucoma [J].
Jaffe, GJ ;
Caprioli, J .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 137 (01) :156-169
[7]   Reproducibility of macular thickness and volume using zeiss optical coherence tomography in patients with diabetic macular edema [J].
Krzystolik, Magdalena G. ;
Strauber, Samara F. ;
Ai-ello, Lloyd Paul ;
Beek, Roy W. ;
Berger, Brian B. ;
Bressler, Neil M. ;
Browning, David J. ;
Chambers, Robert B. ;
Danis, Ronald P. ;
Davis, Matthew D. ;
Glassman, Adam R. ;
Gonzalez, Victor H. ;
Greenberg, Paul B. ;
Gross, Jeffrey G. ;
Kim, Judy E. ;
Kollman, Craig .
OPHTHALMOLOGY, 2007, 114 (08) :1520-1525
[8]   RETINAL THICKNESS AND VOLUME MEASUREMENTS IN DIABETIC MACULAR EDEMA A Comparison of Four Optical Coherence Tomography Systems [J].
Lammer, Jan ;
Scholda, Christoph ;
Pruente, Christian ;
Benesch, Thomas ;
Schmidt-Erfurth, Ursula ;
Bolz, Matthias .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2011, 31 (01) :48-55
[9]   Reproducibility of retinal mapping using optical coherence tomography [J].
Massin, P ;
Vicaut, E ;
Haouchine, B ;
Erginay, A ;
Paques, M ;
Gaudric, A .
ARCHIVES OF OPHTHALMOLOGY, 2001, 119 (08) :1135-1142
[10]   Three-dimensional imaging of the foveal photoreceptor layer in central serous chorioretinopathy using high-speed optical coherence tomography [J].
Ojima, Yumiko ;
Hangai, Masanori ;
Sasahara, Manabu ;
Gotoh, Norimoto ;
Inoue, Ryo ;
Yasuno, Yoshiaki ;
Makita, Shuichi ;
Yatagai, Toyohiko ;
Tsujikawa, Akitaka ;
Yoshimura, Nagahisa .
OPHTHALMOLOGY, 2007, 114 (12) :2197-2207