Quantification of Aortic Valve Stenosis Head-to-Head Comparison of 64-Slice Spiral Computed Tomography With Transesophageal and Transthoracic Echocardiography and Cardiac Catheterization

被引:19
作者
Lembcke, Alexander [1 ,2 ]
Kivelitz, Dietmar E. [1 ,2 ]
Borges, Adrian C. [3 ]
Lachnitt, Andre [2 ]
Hein, Patrick A. [1 ]
Dohmen, Pascal M. [4 ]
Thiele, Holger [5 ]
机构
[1] Charite, Inst Radiol, Dept Radiol, D-13353 Berlin, Germany
[2] Univ Leipzig, Ctr Heart, Dept Radiol, Leipzig, Germany
[3] Charite, Dept Cardiol, D-13353 Berlin, Germany
[4] Charite, Dept Cardiovasc Surg, D-13353 Berlin, Germany
[5] Univ Leipzig, Ctr Heart, Dept Cardiol, Leipzig, Germany
关键词
aortic valve stenosis; computed tomography; cardiac catheterization; echocardiography; quantification; CORONARY-ARTERY-DISEASE; VALVULAR STENOSIS; PRESSURE RECOVERY; AREA ASSESSMENT; GORLIN FORMULA; ORIFICE AREA; MULTIPLANE; PLANIMETRY; CT; ANGIOGRAPHY;
D O I
10.1097/RLI.0b013e31818f769b
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: We sought to evaluate the accuracy of multislice computed tomography (MSCT) with 64 detector rows for determination of the aortic valve area (AVA) compared with transesophageal and transthoracic echocardiography (TEE and TTE) and cardiac catheterization (CATH). Materials and Methods: MSCT, TEE, TTE, and CATH were performed in 36 patients with aortic valve stenosis. AVA was determined by planimetry on MSCT and TEE and calculated using the continuity equation on Doppler TTE and the Gorlin formula on CATH. Results: The mean AVA on MSCT (0.88 +/- 0.39 cm(2)) was not significantly different from TEE (0.94 +/- 0.41 cm(2); P > 0.05) but significantly larger than TTE (0.74 +/- 0.28 cm(2); P < 0.001) and CATH (0.75 +/- 0.31 cm(2); p < 0.001). A good correlation with acceptable limits of agreement was found between MSCT and TTE (r = 0.91, limits +/- 0.35 cm(2)) and between MSCT and CATH (r = 0.91, limits -0.32 cm2). An inferior correlation with wider limits of agreement was found between MSCT and TEE (r = 0.82, limits +/- 0.48 cm(2)), but this applied also between TEE and TTE (r = 0.79, limits 0.51 cm(2)) and between TEE and CATH (r = 0.78, limits +/- 0.52 cm(2)). Conclusions: AVA determined by MSCT correlated well with TTE and CATH, but a systematic difference must be taken into account when using MSCT findings for therapeutic decision-making. Validation against both TTE and CATH revealed a superior correlation and narrower limits of agreement for MSCT than for TEE suggesting that AVA planimetry with MSCT is more reliable than with TEE.
引用
收藏
页码:7 / 14
页数:8
相关论文
共 49 条
[1]   Aortic stenosis: Comparative evaluation of 16-detector row CT and echocardiography [J].
Alkadhi, H ;
Wildermuth, S ;
Plass, A ;
Bettex, D ;
Baumert, B ;
Leschka, S ;
Desbiolles, LM ;
Marincek, B ;
Boehm, T .
RADIOLOGY, 2006, 240 (01) :47-55
[2]   EFFECT OF CATHETER POSITIONING ON THE VARIABILITY OF MEASURED GRADIENT IN AORTIC-STENOSIS [J].
ASSEY, ME ;
ZILE, MR ;
USHER, BW ;
KARAVAN, MP ;
CARABELLO, BA .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 30 (04) :287-292
[3]   Comparison of transesophageal echocardiographic, Fick, and thermodilution cardiac output in critically ill patients [J].
Axler, O ;
Tousignant, C ;
Thompson, CR ;
DallavaSantucci, J ;
Phang, PT ;
Russell, JA ;
Walley, KR .
JOURNAL OF CRITICAL CARE, 1996, 11 (03) :109-116
[4]   Is there a role for multislice computed tomography in aortic stenosis? [J].
Bamgartner, Helmut .
EUROPEAN HEART JOURNAL, 2006, 27 (24) :2923-2924
[5]   Influence of ejection fraction and valvular regurgitation on the accuracy of aortic valve area determination [J].
Berglund, H ;
Kim, CJ ;
Nishioka, T ;
Luo, H ;
Siegel, RJ .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2001, 18 (01) :65-72
[6]   Planimetry of aortic valve area using multiplane transoesophageal echocardiography is not a reliable method for assessing severity of aortic stenosis [J].
Bernard, Y ;
Meneveau, N ;
Vuillemenot, A ;
Magnin, D ;
Anguenot, T ;
Schiele, F ;
Bassand, JP .
HEART, 1997, 78 (01) :68-73
[7]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[8]   ACC/AHA 2006 guidelines for the management of patients with valvular heart disease [J].
Bonow, Robert O. ;
Carabello, Blase A. ;
Chatterjee, Kanu ;
de Leon, Antonio C., Jr. ;
Faxon, David P. ;
Freed, Michael D. ;
Gaasch, William H. ;
Lytle, Bruce Whitney ;
Nishimura, Rick A. ;
O'Gara, Patrick T. ;
O'Rourke, Robert A. ;
Otto, Catherine M. ;
Shah, Pravin M. ;
Shanewise, Jack S. ;
Smith, Sidney C., Jr. ;
Jacobs, Alice K. ;
Adams, Cynthia D. ;
Anderson, Jeffrey L. ;
Antman, Elliott M. ;
Faxon, David P. ;
Fuster, Valentin ;
Halperin, Jonathan L. ;
Hiratzka, Loren F. ;
Hunt, Sharon A. ;
Lytle, Bruce W. ;
Nishimura, Rick ;
Page, Richard L. ;
Riegel, Barbara .
CIRCULATION, 2006, 114 (05) :E84-E231
[9]   Diagnosis of aortic valvular stenosis by multislice cardiac computed tomography [J].
Bouvier, Erik ;
Logeart, Damien ;
Sablayrolles, Jean-Louis ;
Feignoux, Jacques ;
Scheuble, Claude ;
Touche, Thierry ;
Thabut, Gabriel ;
Cohen-Solal, Alain .
EUROPEAN HEART JOURNAL, 2006, 27 (24) :3033-3038
[10]   Assessment of global left and right ventricular function using dual-source computed tomography (DSCT) in comparison to MRI -: An experimental study in a porcine model [J].
Bruners, Philipp ;
Mahnken, Andreas H. ;
Knackstedt, Christian ;
Lithmann, Nadja ;
Spuentrup, Ehnar ;
Das, Marco ;
Hohl, Christian ;
Wildberger, Joachim E. ;
Schmitz-Rode, Thomas ;
Guenther, Rolf W. ;
Muehlenbruch, Georg .
INVESTIGATIVE RADIOLOGY, 2007, 42 (11) :756-764