A MPPC Based Tool for Timing and Spatial Resolution Characterization of PET Detectors

被引:0
作者
Berg, Eric J. [1 ]
Goertzen, Andrew L. [2 ]
机构
[1] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
[2] Univ Manitoba, Dept Radiol Phys & Astron, Winnipeg, MB, Canada
来源
2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC) | 2012年
基金
加拿大自然科学与工程研究理事会;
关键词
PERFORMANCE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
When developing new detectors for positron emission tomography (PET) imaging it is necessary to characterize the performance in terms of spatial and timing resolution in order to understand how the detector performs relative to existing technology. With the move toward time-of-flight PET (TOF PET) due to its benefits for clinical imaging, characterization of the timing performance of PET detectors is taking on an increased importance. We present a probe designed to facilitate the simultaneous measurement of spatial and timing resolution of a PET detector using an electronically collimated beam of 511 keV photons. The design of the probe uses two Multi-Pixel Photon Counting (MPPC) single pixel detectors. The first, used to generate the timing signal, is coupled to a plastic scintillator containing an embedded positron emitting source. The second MPPC detector is coupled to a single LYSO crystal and is used to electronically collimate the 511 keV photon beam. Several features are built into the probe to facilitate the characterization of a PET detector under test including: 1) the two MPPC detectors are mounted on an arm that can be rotated in 15 degrees steps in order to allow characterization of spatial and timing resolution as a function of 511 keV photon beam incidence angle; 2) the effective size of the 511 keV photon beam can be varied by changing the distance between the two MPPC detectors, thus changing the geometric magnification (or minification) of the beam; 3) the probe can be used to acquire a flood irradiation timing measurement if only the output of the MPPC coupled to the plastic scintillator is used or the beam can be collimated by taking a coincidence with the LYSO detector.
引用
收藏
页码:3174 / 3177
页数:4
相关论文
共 8 条
[1]  
Hamamatsu Photonics K.K., 2009, MPPC MULT PHOT COUNT
[2]   Evaluation of an instrument to improve PET timing alignment [J].
Hancock, J. ;
Thompson, C. J. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 620 (2-3) :343-350
[3]   Physical and clinical performance of the mCT time-of-flight PET/CT scanner [J].
Jakoby, B. W. ;
Bercier, Y. ;
Conti, M. ;
Casey, M. E. ;
Bendriem, B. ;
Townsend, D. W. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (08) :2375-2389
[4]   Design and performance of a new pixelated-LSO/PSPMT gamma-ray detector for high resolution PET imaging [J].
Mintzer, Robert A. ;
Siegel, Stefan B. .
2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, :3418-3422
[5]   A novel, SiPM-array-based, monolithic scintillator detector for PET [J].
Schaart, Dennis R. ;
van Dam, Herman T. ;
Seifert, Stefan ;
Vinke, Ruud ;
Dendooven, Peter ;
Lohner, Herbert ;
Beekman, Freek J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (11) :3501-3512
[6]   Investigating the temporal resolution limits of scintillation detection from pixellated elements: comparison between experiment and simulation [J].
Spanoudaki, V. Ch ;
Levin, C. S. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (03) :735-756
[7]  
Surti S, 2007, J NUCL MED, V48, P471
[8]   Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodes [J].
Yang, Yongfeng ;
Dokhale, Purushottam A. ;
Silverman, Robert W. ;
Shah, Kanai S. ;
McClish, Mickel A. ;
Farrell, Richard ;
Entine, Gerald ;
Cherry, Simon R. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (09) :2131-2142