In vitro biological response of plasma electrolytically oxidized and plasma-sprayed hydroxyapatite coatings on Ti-6Al-4V alloy

被引:47
|
作者
Yeung, Wing Kiu [1 ]
Reilly, Gwendolen C. [1 ,2 ]
Matthews, Allan [1 ]
Yerokhin, Aleksey [1 ]
机构
[1] Univ Sheffield, Dept Mat Sci & Engn, Sheffield S1 3JD, S Yorkshire, England
[2] Univ Sheffield, Kroto Res Inst, Sheffield S3 7HQ, S Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
plasma electrolytic oxidation; plasma spraying; osteoblast; hydroxyapatite; collagen; Ti-6Al-4V; MICRO-ARC OXIDATION; BIOMEDICAL APPLICATIONS; TITANIUM-ALLOYS; HEAT-TREATMENT; HYDROTHERMAL TREATMENT; ELECTROPHORETIC DEPOSITION; SURFACE MODIFICATION; CALCIUM PHOSPHATES; ALKALINE-SOLUTIONS; PART;
D O I
10.1002/jbm.b.32899
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Plasma electrolytic oxidation (PEO) is a relatively new surface modification process that may be used as an alternative to plasma spraying methods to confer bioactivity to Ti alloy implants. The aim of this study was to compare physical, chemical and biological surface characteristics of two coatings applied by PEO processes, containing different calcium phosphate (CaP) and titanium dioxide phases, with a plasma-sprayed hydroxyapatite (HA) coating. Coating characteristics were examined by X-ray diffraction, energy dispersive X-ray spectroscopy, scanning electron microscopy, surface profilometry, and wettability tests. The biological properties were determined using the human osteoblastic cell line MG-63 to assess cell viability, calcium and collagen synthesis. The tests showed that PEO coatings are significantly more hydrophilic (6%) and have 78% lower surface roughness (Ra) than the plasma-sprayed coatings. Cell behavior was demonstrated to be strongly dependent on the phase composition and surface distribution of elements in the PEO coating. MG-63 viability for the TiO2-based PEO coating containing amorphous CaPs was significantly lower than that for the PEO coating containing crystalline HA and the plasma-sprayed coating. However, collagen synthesis on both the CaP and the TiO2 PEO coatings was significantly higher (92% and 71%, respectively) than on the plasma-sprayed coating after 14 days. PEO has been demonstrated to be a promising method for coating of orthopedic implant surfaces. (c) 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2013.
引用
收藏
页码:939 / 949
页数:11
相关论文
共 50 条
  • [1] Characteristics of plasma-sprayed bioactive glass coatings on Ti-6Al-4V alloy: An in vitro study
    Lee, TM
    Chang, E
    Wang, BC
    Yang, CY
    SURFACE & COATINGS TECHNOLOGY, 1996, 79 (1-3): : 170 - 177
  • [2] Plasma-sprayed coatings for oxidation protection on creep of the Ti-6Al-4V alloy
    Reis, DAP
    Silva, CRM
    Nono, MCA
    Barboza, MJR
    Piorino-Neto, F
    Perez, EAC
    MATERIALS AT HIGH TEMPERATURES, 2005, 22 (3-4) : 449 - 452
  • [3] In vitro stability of plasma-sprayed hydroxyapatite coatings on Ti-6Al-4V implants under cyclic loading
    Zhang, CG
    Leng, Y
    Zhang, XD
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2000, 50 (02): : 267 - 275
  • [4] Elastic and plastic behavior of plasma-sprayed hydroxyapatite coatings on a Ti-6Al-4V substrate
    Zhang, CG
    Leng, Y
    Chen, JY
    BIOMATERIALS, 2001, 22 (11) : 1357 - 1363
  • [5] Characterization of Vacuum Plasma Sprayed Reinforced Hydroxyapatite Coatings on Ti-6Al-4V alloy
    Singh, Amardeep
    Singh, Gurbhinder
    Chawla, Vikas
    TRANSACTIONS OF THE INDIAN INSTITUTE OF METALS, 2017, 70 (10) : 2609 - 2628
  • [6] In vitro studies of plasma-sprayed hydroxyapatite/Ti-6Al-4V composite coatings in simulated body fluid (SBF)
    Gu, YW
    Khor, KA
    Cheang, P
    BIOMATERIALS, 2003, 24 (09) : 1603 - 1611
  • [7] Analysis of phase changes in plasma-sprayed Ti-6Al-4V/hydroxyapatite composite coatings by DSC
    Feng, CF
    Khor, KA
    Gu, YW
    Cheang, P
    MATERIALS LETTERS, 2001, 51 (01) : 88 - 93
  • [8] TEM and STEM analysis on heat-treated and in vitro plasma-sprayed hydroxyapatite/Ti-6Al-4V composite coatings
    Dong, ZL
    Khor, KA
    Quek, CH
    White, TJ
    Cheang, P
    BIOMATERIALS, 2003, 24 (01) : 97 - 105
  • [9] Mechanical properties of vacuum plasma sprayed reinforced hydroxyapatite coatings on Ti-6Al-4V alloy
    Singh, Amardeep
    Singh, Gurbhinder
    Chawla, Vikas
    JOURNAL OF THE AUSTRALIAN CERAMIC SOCIETY, 2017, 53 (02) : 795 - 810
  • [10] Mechanical properties of vacuum plasma sprayed reinforced hydroxyapatite coatings on Ti-6Al-4V alloy
    Amardeep Singh
    Gurbhinder Singh
    Vikas Chawla
    Journal of the Australian Ceramic Society, 2017, 53 : 795 - 810