Informatics in Radiology Dual-Energy Electronic Cleansing for Fecal-Tagging CT Colonography1

被引:23
作者
Cai, Wenli [1 ,2 ]
Kim, Se Hyung [3 ]
Lee, June-Goo [1 ,2 ]
Yoshida, Hiroyuki [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
[3] Seoul Natl Univ Hosp, Dept Radiol, Coll Med, Seoul 110744, South Korea
关键词
VIRTUAL COLONOSCOPY; COMPUTED-TOMOGRAPHY; CATHARTIC PREPARATION; RECONSTRUCTION; SEGMENTATION; FEASIBILITY; EXPERIENCE; FILTRATION; NEOPLASIA; ACCURACY;
D O I
10.1148/rg.333125039
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Electronic cleansing (EC) is an emerging technique for the removal of tagged fecal materials at fecal-tagging computed tomographic (CT) colonography. However, existing EC methods may generate various types of artifacts that severely impair the quality of the cleansed CT colonographic images. Dual-energy fecal-tagging CT colonography is regarded as a nextgeneration imaging modality. EC that makes use of dual-energy fecal-tagging CT colonographic images promises to be effective in reducing cleansing artifacts by means of applying the material decomposition capability of dual-energy CT. The dual-energy index (DEI), which is calculated from the relative change in the attenuation values of a material at two different photon energies, is a reliable and effective indicator for differentiating tagged fecal materials from various types of tissues on fecal-tagging CT colonographic images. A DEI-based dual-energy EC scheme uses the DEI to help differentiate the colonic lumen-including the luminal air, tagged fecal materials, and air-tagging mixture-from the colonic soft-tissue structures, and then segments the entire colonic lumen for cleansing of the tagged fecal materials. As a result, dual-energy EC can help identify partialvolume effects in the air-tagging mixture and inhomogeneous tagging in residual fecal materials, the major causes of EC artifacts. This technique has the potential to significantly improve the quality of EC and promises to provide images of a cleansed colon that are free of the artifacts commonly observed with conventional single-energy EC methods.
引用
收藏
页码:891 / 912
页数:22
相关论文
共 54 条
[1]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[2]  
[Anonymous], 1998, P SICCV
[3]  
[Anonymous], 2002, Level Set Methods and Dynamic Implicit Surfaces
[4]   Dual-energy CT-based material extraction for tissue segmentation in Monte Carlo dose calculations [J].
Bazalova, Magdalena ;
Carrier, Jean-Francois ;
Beaulieu, Luc ;
Verhaegen, Frank .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (09) :2439-2456
[5]  
Bushberg J.T., 1994, ESSENTIAL PHYS MED I
[6]  
Cai W, 2011, LECT NOTES COMPUT SC, V6668, P1
[7]  
Cai W., 2011, RADIOLOGICAL SOC N A, P175
[8]  
Cai W, 2012, LECT NOTES COMPUT SC, V7601, P88
[9]  
Cai W, 2009, RAD SOC N AM SCI ASS, P466
[10]   Structure-analysis method for electronic cleansing in cathartic and noncathartic CT colonography [J].
Cai, Wenli ;
Zalis, Michael E. ;
Naeppi, Janne ;
Harris, Gordon J. ;
Yoshida, Hiroyuki .
MEDICAL PHYSICS, 2008, 35 (07) :3259-3277