Measurement of the soft X-ray response of P-channel back-illuminated CCD

被引:4
作者
Ueda, Shutaro [1 ]
Hayashida, Kiyoshi [1 ]
Nakajima, Hiroshi [1 ]
Anabuki, Naohisa [1 ]
Tsunemi, Hiroshi [1 ]
Kan, Hiroaki [1 ]
Kohmura, Takayoshi [2 ]
Ikeda, Shoma [2 ]
Kaneko, Kenta [2 ]
Watanabe, Tatsuo [2 ]
Mori, Koji [3 ]
Nobukawa, Masayoshi [4 ]
Murakami, Hiroshi [5 ]
Sakata, Kazuya [5 ]
Todoroki, Shotaro [5 ]
Yagihashi, Nobuyoshi [5 ]
Mizuno, Eiki [5 ]
Muramatsu, Masaharu [6 ]
Suzuki, Hisanori [6 ]
Takagi, Shin'ichiro [6 ]
机构
[1] Osaka Univ, Dept Earth & Space Sci, Grad Sch Sci, Toyonaka, Osaka 5600043, Japan
[2] Kogakuin Univ, Dept Phys, Hachioji, Tokyo 1920015, Japan
[3] Miyazaki Univ, Dept Appl Phys, Fac Engn, Miyazaki 8892192, Japan
[4] Kyoto Univ, Dept Phys, Grad Sch Sci, Sakyo Ku, Kyoto 6068502, Japan
[5] Rikkyo Univ, Dept Phys, Fac Sci, Toshima Ku, Tokyo 1718501, Japan
[6] Hamamatsu Photon KK, Solid State Div, Hamamatsu, Shizuoka 4358558, Japan
基金
日本学术振兴会;
关键词
X-ray CCD; P-channel BI CCD; Soft X-ray response; ASTRO-H; HIGH-RESISTIVITY SILICON; PHOTON IMAGING CAMERA; XMM-NEWTON; ASTRO-E; PERFORMANCE; SPECTROMETER; CALIBRATION; DEVICES; DAMAGE;
D O I
10.1016/j.nima.2012.11.187
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
P-channel charge-coupled devices (CCDs) made from N-type silicon wafers were originally developed for ground-based optical and near-infrared telescopes. The thick depletion layer of these CCDs provides the significant advantage of high quantum efficiency (QE) for hard X-rays. On the other hand, high QE for soft X-rays is obtained with back-illuminated (BI) and fully depleted CCDs in which only a thin dead layer exists on the surface of incidence. Thus, P-channel BI CCDs can be applicable as superior wide band X-ray detectors. We have developed such a device specifically for the Soft X-ray Imager (SXI) on board the X-ray astronomy satellite ASTRO-H, scheduled to be launched in 2014. We previously reported that the depletion layers of our CCDs, a prototype of SXI-CCDs, have a thickness of more than 200 mu m. In this paper, we report a novel soft X-ray response of P-channel BI CCDs. First, we irradiate fluorescent X-rays of O, F, Na, Al, Si and K to the SXI prototype. This experiment reveals that our CCD has a significant low-energy tail structure in the soft X-ray response. Since the intensity of the low-energy tail is larger for lower X-ray energies, the tail is originated on the CCD surface layer. Then, we fabricate a new type of CCDs by applying an alternative treatment to its surface layer. The soft X-ray response of the CCD is measured by irradiation of monochromatic X-rays from 0.25 keV to 1.8 keV in a synchrotron facility, KEK-PF. The intensity of the low-energy tail for 0.5 keV incident X-ray is one order of magnitude smaller than that for the previous CCD. The same treatment will be applied to the surface layer of the SXI flight model. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:140 / 146
页数:7
相关论文
共 34 条
[1]  
Alig R. C., 1980, PHYS REV, V22
[2]   Proton radiation damage in p-channel CCDs fabricated on high-resistivity silicon [J].
Bebek, C ;
Groom, D ;
Holland, S ;
Karcher, A ;
Kolbe, W ;
Lee, J ;
Levi, M ;
Palaio, N ;
Turko, B ;
Uslenghi, M ;
Wagner, M ;
Wang, G .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) :1221-1225
[3]   CHARGE COUPLED SEMICONDUCTOR DEVICES [J].
BOYLE, WS ;
SMITH, GE .
BELL SYSTEM TECHNICAL JOURNAL, 1970, 49 (04) :587-+
[4]   CCD soft-X-Ray detectors with improved high- and low-energy performance [J].
Burke, BE ;
Gregory, JA ;
Loomis, AH ;
Lesser, M ;
Bautz, MW ;
Kissel, SE ;
Rathman, DD ;
Osgood, RM ;
Cooper, MJ ;
Lind, TA ;
Ricker, GR .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) :2322-2327
[5]   PROPERTIES OF SILICON AND GERMANIUM .2. [J].
CONWELL, EM .
PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1958, 46 (06) :1281-1300
[6]   IONIZATION YIELD OF RADIATIONS .2. THE FLUCTUATIONS OF THE NUMBER OF IONS [J].
FANO, U .
PHYSICAL REVIEW, 1947, 72 (01) :26-29
[7]   Advanced CCD imaging spectrometer (ACIS) instrument on the Chandra X-ray Observatory [J].
Garmire, GP ;
Bautz, MW ;
Ford, PG ;
Nousek, JA ;
Ricker, GR .
X-RAY AND GAMMA-RAY TELESCOPES AND INSTRUMENTS FOR ASTRONOMY, PTS 1 AND 2, 2003, 4851 :28-44
[8]   X-ray imaging spectrometers for Astro-E: Ground calibration in soft X-ray range [J].
Hayashida, K ;
Kitamoto, S ;
Miyata, E ;
Tsunemi, H ;
Yoshita, E ;
Kohmura, T ;
Mori, K ;
Katayama, K ;
Katayama, H ;
Shouho, M ;
Ohta, M ;
Dotani, T ;
Ozaki, M ;
Koyama, K ;
Awaki, H ;
Tsuru, TG ;
Ricker, G ;
Bautz, MW ;
Foster, R ;
Kissel, S .
X-RAY OPTICS, INSTRUMENTS, AND MISSIONS III, 2000, 4012 :123-136
[9]   Soft X-ray Imager(SXI) onboard ASTRO-H [J].
Hayashida, Kiyoshi ;
Tsunemi, Hiroshi ;
Tsuru, Takeshi Go ;
Dotani, Tadayasu ;
Nakajima, Hiroshi ;
Anabuki, Naohisa ;
Ozaki, Masanobu ;
Natsukari, Chikara ;
Hiraga, Junko S. ;
Tomida, Hiroshi ;
Kohmura, Takayoshi ;
Murakami, Hiroshi ;
Mori, Koji ;
Yamauchi, Makoto ;
Hatsukade, Isamu ;
Nishioka, Yusuke ;
Bamba, Aya ;
Uchida, Hiroyuki ;
Nobukawa, Masayoshi ;
Tanaka, Takaaki ;
Nagino, Ryo ;
Ueda, Shutaro ;
Fujinaga, Takahisa ;
Matsuta, Keiko ;
Ohnishi, Takao ;
Doty, John P. .
SPACE TELESCOPES AND INSTRUMENTATION 2012: ULTRAVIOLET TO GAMMA RAY, 2012, 8443
[10]   Development of the Soft X-ray Imager (SXI) for ASTRO-H [J].
Hayashida, Kiyoshi ;
Tsunemi, Hiroshi ;
Tsuru, Takeshi Go ;
Dotani, Tadayasu ;
Nakajima, Hiroshi ;
Anabuki, Naohisa ;
Ozaki, Masanobu ;
Natsukari, Chikara ;
Hiraga, Junko S. ;
Tomida, Hiroshi ;
Kohmura, Takayoshi ;
Murakami, Hiroshi ;
Mori, Koji ;
Yamauchi, Makoto ;
Hatsukade, Isamu ;
Bamba, Aya ;
Uchida, Hiroyuki ;
Nobukawa, Masayoshi ;
Ueda, Shutaro ;
Fujinaga, Takahisa ;
Matsuta, Keiko ;
Ohnishi, Takao ;
Doty, John P. .
UV, X-RAY, AND GAMMA-RAY SPACE INSTRUMENTATION FOR ASTRONOMY XVII, 2011, 8145