Electrochemical Synthesis of a Polyaniline Network on a Poly(o-aminophenol) Modified Glassy Carbon Electrode and Its Use for the Simultaneous Determination of Ascorbic Acid and Uric Acid

被引:8
|
作者
Zhang, Lei [1 ]
Wang, Li-Lin [1 ]
机构
[1] Shanghai Normal Univ, Dept Chem, Coll Life & Environm Sci, Shanghai 200234, Peoples R China
关键词
CHEMICALLY-MODIFIED ELECTRODE; SELECTIVE VOLTAMMETRIC METHOD; ELECTROCATALYTIC OXIDATION; SULFONATED POLYANILINE; COVALENT MODIFICATION; GOLD NANOPARTICLES; PASTE ELECTRODES; O-AMINOPHENOL; FILM; DOPAMINE;
D O I
10.2116/analsci.28.1001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A polyaniline (PAN) network structure was fabricated on a poly(o-aminophenol) (POAP) modified glassy carbon electrode (GCE) by using a three-step electrochemical deposition procedure, and applied to the electro-catalytic oxidation of ascorbic acid (AA) and uric acid (UA). Scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) have been employed to investigate the PAN network structure on a POAP modified GCE (PAN-OAP/GCE), which indicated the formation of a 3-dimensional (3D) non-periodic PAN network with good electrical contract and the maintenance of the electro-activity of PAN in neutral and even in alkaline media. Because of its different catalytic effect towards the electro-oxidation of AA and UA, the PAN-OAP/GCE could resolve the overlapped voltammetric response of AA and UA into two sharp and well-defined voltammetric peaks with both CV and differential pulse voltammetry (DPV), which could be applied for the selective and simultaneous determination of AA and UA in their binary mixture. Under the optimum conditions, the calibration curves for AA and UA were in the range of 2.5 - 6200 and 0.5 - 450 mu mol L-1 with correlation coefficients of 0.998 and 0.998, respectively. The detection limits (S/N = 3) are 1.4 and 0.3 mu mol L-1 for AA and UA, respectively. Besides good stability and reproducibility, the PAN-OAP/GCE also exhibited good sensitivity and selectivity. The proposed method has been applied to the simultaneous detection of AA and UA in human urine with satisfactory result.
引用
收藏
页码:1001 / 1007
页数:7
相关论文
共 50 条
  • [21] Electrochemical synthesis of copolymer of aniline and o-aminophenol and its use to the electrocatalytic oxidation of ascorbic acid
    Zhang, Lei
    Lian, Jiying
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2007, 611 (1-2) : 51 - 59
  • [22] Fabrication of poly(orthanilic acid)-multiwalled carbon nanotubes composite film-modified glassy carbon electrode and its use for the simultaneous determination of uric acid and dopamine in the presence of ascorbic acid
    Zhang, Lei
    Shi, Zhige
    Lang, Qiuhua
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2011, 15 (04) : 801 - 809
  • [23] Simultaneous determination of ascorbic acid, adrenaline and uric acid at a hematoxylin multi-wall carbon nanotube modified glassy carbon electrode
    Zare, Hamid R.
    Nasirizadeh, Navid
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 143 (02): : 666 - 672
  • [24] Selective determination of uric acid in the presence of ascorbic acid at poly(p-aminobenzene sulfonic acid)-modified glassy carbon electrode
    Tang, Hao
    Hu, Guang-zhi
    Jiang, Sheng-xiang
    Liu, Xia
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2009, 39 (12) : 2323 - 2328
  • [25] Electrochemical reduced graphene oxide-poly (eriochrome black T)/gold nanoparticles modified glassy carbon electrode for simultaneous determination of ascorbic acid, dopamine and uric acid
    Edris, Nusiba Mohammed Modawe Alshik
    Abdullah, Jaafar
    Kamaruzaman, Sazlinda
    Saiman, Mohd Izham
    Sulaiman, Yusran
    ARABIAN JOURNAL OF CHEMISTRY, 2018, 11 (08) : 1301 - 1312
  • [26] Simultaneous electrochemical determination of epinephrine and uric acid in the presence of ascorbic acid using SnO2/graphene nanocomposite modified glassy carbon electrode
    Lavanya, N.
    Fazio, E.
    Neri, F.
    Bonavita, A.
    Leonardi, S. G.
    Neri, G.
    Sekar, C.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 221 : 1412 - 1422
  • [27] Simultaneous Determination of Dopamine and Uric Acid in the Presence of Ascorbic Acid at the Indole-3-Carboxaldehyde Modified Glassy Carbon Electrode
    Deletioglu, Didem
    Hasdemir, Erdogan
    Solak, Ali O.
    CURRENT ANALYTICAL CHEMISTRY, 2010, 6 (03) : 203 - 208
  • [28] Simultaneous electrochemical determination of dopamine and ascorbic acid using poly (L-serine) modified carbon paste electrode
    Chitravathi, S.
    Swamy, B. E. Kumara
    Mamatha, G. P.
    Sherigara, B. S.
    JOURNAL OF MOLECULAR LIQUIDS, 2011, 160 (03) : 193 - 199
  • [29] Simultaneous electroanalysis of dopamine, ascorbic acid and uric acid by poly (vinyl alcohol) covalently modified glassy carbon electrode
    Li, YX
    Lin, XQ
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 115 (01) : 134 - 139
  • [30] Simultaneous determination of ascorbic acid, dopamine, uric acid and tryptophan on gold nanoparticles/overoxidized-polyimidazole composite modified glassy carbon electrode
    Wang, Cun
    Yuan, Ruo
    Chai, Yaqin
    Chen, Shihong
    Hu, Fangxin
    Zhang, Meihe
    ANALYTICA CHIMICA ACTA, 2012, 741 : 15 - 20