Electrochemical Synthesis of a Polyaniline Network on a Poly(o-aminophenol) Modified Glassy Carbon Electrode and Its Use for the Simultaneous Determination of Ascorbic Acid and Uric Acid

被引:8
|
作者
Zhang, Lei [1 ]
Wang, Li-Lin [1 ]
机构
[1] Shanghai Normal Univ, Dept Chem, Coll Life & Environm Sci, Shanghai 200234, Peoples R China
关键词
CHEMICALLY-MODIFIED ELECTRODE; SELECTIVE VOLTAMMETRIC METHOD; ELECTROCATALYTIC OXIDATION; SULFONATED POLYANILINE; COVALENT MODIFICATION; GOLD NANOPARTICLES; PASTE ELECTRODES; O-AMINOPHENOL; FILM; DOPAMINE;
D O I
10.2116/analsci.28.1001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A polyaniline (PAN) network structure was fabricated on a poly(o-aminophenol) (POAP) modified glassy carbon electrode (GCE) by using a three-step electrochemical deposition procedure, and applied to the electro-catalytic oxidation of ascorbic acid (AA) and uric acid (UA). Scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) have been employed to investigate the PAN network structure on a POAP modified GCE (PAN-OAP/GCE), which indicated the formation of a 3-dimensional (3D) non-periodic PAN network with good electrical contract and the maintenance of the electro-activity of PAN in neutral and even in alkaline media. Because of its different catalytic effect towards the electro-oxidation of AA and UA, the PAN-OAP/GCE could resolve the overlapped voltammetric response of AA and UA into two sharp and well-defined voltammetric peaks with both CV and differential pulse voltammetry (DPV), which could be applied for the selective and simultaneous determination of AA and UA in their binary mixture. Under the optimum conditions, the calibration curves for AA and UA were in the range of 2.5 - 6200 and 0.5 - 450 mu mol L-1 with correlation coefficients of 0.998 and 0.998, respectively. The detection limits (S/N = 3) are 1.4 and 0.3 mu mol L-1 for AA and UA, respectively. Besides good stability and reproducibility, the PAN-OAP/GCE also exhibited good sensitivity and selectivity. The proposed method has been applied to the simultaneous detection of AA and UA in human urine with satisfactory result.
引用
收藏
页码:1001 / 1007
页数:7
相关论文
共 50 条
  • [1] Simultaneous electrochemical determination of dopamine, ascorbic acid and uric acid using poly(acid chrome blue K) modified glassy carbon electrode
    Zhang, Rui
    Jin, Gen-Di
    Chen, Da
    Hu, Xiao-Ya
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 138 (01): : 174 - 181
  • [2] Electrochemical characterization of poly(eriochrome black T) modified glassy carbon electrode and its application to simultaneous determination of dopamine, ascorbic acid and uric acid
    Yao, Hong
    Sun, Yuanyuan
    Lin, Xinhua
    Tang, Yuhai
    Huang, Liying
    ELECTROCHIMICA ACTA, 2007, 52 (20) : 6165 - 6171
  • [3] Electrochemical characterization of poly(fuchsine acid) modified glassy carbon electrode and its application for simultaneous determination of ascorbic acid, epinephrine and uric acid
    Taei, M.
    Hasanpour, F.
    Tavakkoli, N.
    Bahrameian, M.
    JOURNAL OF MOLECULAR LIQUIDS, 2015, 211 : 353 - 362
  • [4] Simultaneous determination of ascorbic acid, dopamine and uric acid using poly(4-aminobutyric acid) modified glassy carbon electrode
    Zheng, Xinyu
    Zhou, Xuechou
    Ji, Xiaoyan
    Lin, Ruiyu
    Lin, Wenxiong
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 178 : 359 - 365
  • [5] Simultaneous determination of doparnine, ascorbic acid and uric acid at poly (Evans Blue) modified glassy carbon electrode
    Lin, Liqing
    Chen, Jinghua
    Yao, Hong
    Chen, Yuanzhong
    Zheng, Yanjie
    Lin, Xinhua
    BIOELECTROCHEMISTRY, 2008, 73 (01) : 11 - 17
  • [6] Carbon nanohorns/poly(glycine) modified glassy carbon electrode: Preparation, characterization and simultaneous electrochemical determination of uric acid, dopamine and ascorbic acid
    Zhang, Guangli
    He, Ping
    Feng, Wanru
    Ding, Shuangshuang
    Chen, Jingchao
    Li, Lian
    He, Huichao
    Zhang, Susu
    Dong, Faqin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 760 : 24 - 31
  • [7] Simultaneous electrochemical detection of uric acid and ascorbic acid at a silver doped poly(glutamic acid) modified glassy carbon electrode
    Sun, D. M.
    Hu, W. N.
    Ma, W.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (03) : 310 - 316
  • [8] Simultaneous determination of uric acid, dopamine and ascorbic acid based on poly(bromocresol green) modified glassy carbon electrode
    Ouyang, Xiaoqian
    Luo, Liqiang
    Ding, Yaping
    Liu, Bingdi
    Xu, Duo
    Huang, Anquan
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 748 : 1 - 7
  • [9] Glassy carbon electrode modified with poly(dibromofluorescein) for the selective determination of dopamine and uric acid in the presence of ascorbic acid
    Wang, Yan
    Xiao, Yan
    MICROCHIMICA ACTA, 2012, 178 (1-2) : 123 - 130
  • [10] Glassy carbon electrode modified with poly(dibromofluorescein) for the selective determination of dopamine and uric acid in the presence of ascorbic acid
    Yan Wang
    Yan Xiao
    Microchimica Acta, 2012, 178 : 123 - 130