D90: The Strongest Contributor to Setting Time in Mineral Trioxide Aggregate and Portland Cement

被引:23
作者
Ha, William N. [1 ]
Bentz, Dale P. [2 ]
Kahler, Bill [1 ]
Walsh, Laurence J. [1 ]
机构
[1] Univ Queensland, Sch Dent, UQ Oral Hlth Ctr, Herston, Qld 4006, Australia
[2] NIST, Mat & Struct Syst Div, Engn Lab, Gaithersburg, MD 20899 USA
关键词
Hydration; mineral trioxide aggregate; particle size; Portland cement; root canal filling materials; setting time; PHYSICAL-PROPERTIES; PARTICLE-SIZE; SHAPE; MTA;
D O I
10.1016/j.joen.2015.02.033
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The setting times of commercial mineral trioxide aggregate (MTA) and Portland cements vary. It was hypothesized that much of this variation was caused by differences in particle size distribution. Methods: Two gram samples from 11 MTA-type cements were analyzed by laser diffraction to determine their particle size distributions characterized by their percentile equivalent diameters (the 10th percentile, the median, and the 90th percentile [d90], respectively). Setting time data were received from manufacturers who performed indentation setting time tests as specified by the standards relevant to dentistry, ISO 6786 (9 respondents) or ISO 9917.1 (1 respondent), or not divulged to the authors (1 respondent). In a parallel experiment, 6 samples of different size graded Portland cements were produced using the same cement clinker. The measurement of setting time for Portland cement pastes was performed using American Society for Testing and Materials C 191. Cumulative heat release was measured using isothermal calorimetry to assess the reactions occurring during the setting of these pastes. In all experiments, linear correlations were assessed between setting times, heat release, and the 3 particle size parameters. Results: Particle size varied considerably among MTA cements. For MTA cements, d90 was the particle size characteristic showing the highest positive linear correlation with setting time (r = 0.538). For Portland cement, d90 gave an even higher linear correlation for the initial setting time (r = 0.804) and the final setting time (r = 0.873) and exhibited a strong negative linear correlation for cumulative heat release (r = 0.901). Conclusions: Smaller particle sizes result in faster setting times, with d90 (the largest particles) being most closely correlated with the setting times of the samples.
引用
收藏
页码:1146 / 1150
页数:5
相关论文
共 21 条
[11]   Particle Size Changes in Unsealed Mineral Trioxide Aggregate Powder [J].
Ha, William N. ;
Kahler, Bill ;
Walsh, Laurence James .
JOURNAL OF ENDODONTICS, 2014, 40 (03) :423-426
[12]  
International Organisation for Standardisation, 2009, 133202009 ISO
[13]  
International Organization for Standardization, 2007, 99171 ISO
[14]  
International Organization for Standardization, 2007, 6876 ISO
[15]  
Jang Ga-Yeon, 2013, Restor Dent Endod, V38, P248, DOI 10.5395/rde.2013.38.4.248
[16]   Particle size and shape analysis of MTA finer fractions using Portland cement [J].
Komabayashi, Takashi ;
Spangberg, Larz S. W. .
JOURNAL OF ENDODONTICS, 2008, 34 (06) :709-711
[17]   Comparative analysis of the particle size and shape of commercially available mineral trioxide aggregates and Portland cement:: A study with a flow particle image analyzer [J].
Komabayashi, Takashi ;
Spangberg, Larz S. W. .
JOURNAL OF ENDODONTICS, 2008, 34 (01) :94-98
[18]   Physical properties and biological/odontogenic effects of an experimentally developed fast-setting α-tricalcium phosphate-based pulp capping material [J].
Lee, Jun-Bong ;
Park, Su-Jung ;
Kim, Hyun-Ha ;
Kwon, Young-Sun ;
Lee, Kwang-Won ;
Min, Kyung-San .
BMC ORAL HEALTH, 2014, 14
[19]   Mineral Trioxide Aggregate: A Comprehensive Literature Review-Part III: Clinical Applications, Drawbacks, and Mechanism of Action [J].
Parirokh, Masoud ;
Torabinejad, Mahmoud .
JOURNAL OF ENDODONTICS, 2010, 36 (03) :400-413
[20]  
Torabinejad J, 1994, WIPO patent publication, Patent No. [WO 94/24955, 199424955]