Estimation of detection limits of a clinical fluorescence optical mammography system for the near-infrared fluorophore IRDye800CW: phantom experiments

被引:3
|
作者
Adams, Arthur [1 ]
Mourik, Jurgen E. M. [2 ,3 ]
van der Voort, Marjolein [4 ]
Pearlman, Paul C. [2 ]
Nielsen, Tim [5 ]
Mali, Willem P. Th M. [1 ]
Elias, Sjoerd G. [1 ,6 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiol, NL-3508 GA Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Image Sci Inst, NL-3508 GA Utrecht, Netherlands
[3] Leiden Univ, Med Ctr, Dept Radiol, Leiden, Netherlands
[4] Philips Res, Eindhoven, Netherlands
[5] Philips Res, Hamburg, Germany
[6] Univ Med Ctr Utrecht, Julius Ctr Hlth Sci & Primary Care, NL-3508 GA Utrecht, Netherlands
关键词
molecular imaging; near-infrared fluorescence optical mammography; IRDye800CW; phantom experiments; detection limits; BREAST-CANCER; INDOCYANINE GREEN; TOMOGRAPHY; LIGHT; DIAGNOSIS; IMAGER; MRI;
D O I
10.1117/1.JBO.17.7.076022
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To evaluate if clinical fluorescence imaging of IRDye800CW is feasible on our fluorescence optical mammography system by estimating detection limits assessed by breast-cancer-simulating phantom experiments. Phantoms (2.1 cm(3), 0.9 cm(3)) with IRDye800CW concentrations of 0.5 to 120 nM were suspended in a 550 cm(3) measurement cup containing 507 surface-mounted source and detector fibers. The cup was filled with optical matching fluid containing IRDye800CW concentrations of 0, 5, 10, or 20 nM. Tomographic fluorescence images were acquired by exciting IRDye800CW at 730 nm; wavelengths above 750 nm were filtered. Signal intensities were calculated over a volume of interest corresponding to the size and location of the phantom in the reconstructed images. Correlations (R-2) were calculated, and detection limits with associated upper 95% prediction interval were estimated. Between-day reproducibility was assessed with intraclass correlation coefficients (ICC). Fluorescent intensities were strongly correlated with phantom IRDye800CW concentrations (R-2:0.983 to 0.999). IRDye800CW detection limits ranged from 0.14 to 2.46 nM (upper 95% prediction limit 4.63 to 18.63 nM). ICC ranged from 0.88 to 1.00. The estimated detection limits for IRDye800CW were in the low-nanomolar range. These results support the start of clinical trials to evaluate the fluorescence optical mammography system using IRDye800CW labeled breast cancer targeting ligands. (C) 2012 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.JBO.17.7.076022]
引用
收藏
页数:6
相关论文
共 4 条
  • [1] Near-Infrared Molecular Imaging of Glioblastoma by Miltuximab®-IRDye800CW as a Potential Tool for Fluorescence-Guided Surgery
    Polikarpov, Dmitry M.
    Campbell, Douglas H.
    McRobb, Lucinda S.
    Wu, Jiehua
    Lund, Maria E.
    Lu, Yanling
    Deyev, Sergey M.
    Davidson, Andrew S.
    Walsh, Bradley J.
    Zvyagin, Andrei V.
    Gillatt, David A.
    CANCERS, 2020, 12 (04)
  • [2] Clinical Trials in Near Infrared Fluorescence Imaging with IRDye 800CW
    Draney, Daniel R.
    MOLECULAR-GUIDED SURGERY: MOLECULES, DEVICES, AND APPLICATIONS, 2015, 9311
  • [3] Near-infrared fluorescent dyes for enhanced contrast in optical mammography: phantom experiments
    Ebert, B
    Sukowski, U
    Grosenick, D
    Wabnitz, H
    Moesta, TK
    Licha, K
    Becker, A
    Semmler, W
    Schlag, PM
    Rinneberg, H
    JOURNAL OF BIOMEDICAL OPTICS, 2001, 6 (02) : 134 - 140
  • [4] Detection of sentinel lymph node with a novel near-infrared fluorescence spectrum system and indocyanine green fluorescence in patients with early breast cancer: First clinical experience
    Ebihara, Yuma
    Kato, Hiroaki
    Narita, Yoshiaki
    Abe, Masaru
    Kubota, Reiko
    Hirano, Satoshi
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2022, 40