Investigation of the usability of conebeam CT data sets for dose calculation

被引:167
作者
Richter, Anne [1 ]
Hu, Qiaoqiao [1 ]
Steglich, Doreen [1 ]
Baier, Kurt [1 ]
Wilbert, Juergen [1 ]
Guckenberger, Matthias [1 ]
Flentje, Michael [1 ]
机构
[1] Univ Wurzburg, Dept Radiat Oncol, D-97070 Wurzburg, Germany
关键词
D O I
10.1186/1748-717X-3-42
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: To investigate the feasibility and accuracy of dose calculation in cone beam CT (CBCT) data sets. Methods: Kilovoltage CBCT images were acquired with the Elekta XVI system, CT studies generated with a conventional multi-slice CT scanner (Siemens Somatom Sensation Open) served as reference images. Material specific volumes of interest (VOI) were defined for commercial CT Phantoms (CATPhan (R) and Gammex RMI (R)) and CT values were evaluated in CT and CBCT images. For CBCT imaging, the influence of image acquisition parameters such as tube voltage, with or without filter (F1 or F0) and collimation on the CT values was investigated. CBCT images of 33 patients (pelvis n = 11, thorax n = 11, head n = 11) were compared with corresponding planning CT studies. Dose distributions for three different treatment plans were calculated in CT and CBCT images and differences were evaluated. Four different correction strategies to match CT values (HU) and density (D) in CBCT images were analysed: standard CT HU-D table without adjustment for CBCT; phantom based HU-D tables; patient group based HU-D tables (pelvis, thorax, head); and patient specific HU-D tables. Results: CT values in the CBCT images of the CATPhan (R) were highly variable depending on the image acquisition parameters: a mean difference of 564 HU +/- 377 HU was calculated between CT values determined from the planning CT and CBCT images. Hence, two protocols were selected for CBCT imaging in the further part of the study and HU-D tables were always specific for these protocols (pelvis and thorax with M20F1 filter, 120 kV; head S10F0 no filter, 100 kV). For dose calculation in real patient CBCT images, the largest differences between CT and CBCT were observed for the standard CT HU-D table: differences were 8.0% +/- 5.7%, 10.9% +/- 6.8% and 14.5% +/- 10.4% respectively for pelvis, thorax and head patients using clinical treatment plans. The use of patient and group based HU-D tables resulted in small dose differences between planning CT and CBCT: 0.9% +/- 0.9%, 1.8% +/- 1.6%, 1.5% +/- 2.5% for pelvis, thorax and head patients, respectively. The application of the phantom based HU-D table was acceptable for the head patients but larger deviations were determined for the pelvis and thorax patient populations. Conclusion: The generation of three HU-D tables specific for the anatomical regions pelvis, thorax and head and specific for the corresponding CBCT image acquisition parameters resulted in accurate dose calculation in CBCT images. Once these HU-D tables are created, direct dose calculation on CBCT datasets is possible without the need of a reference CT images for pixel value calibration.
引用
收藏
页数:13
相关论文
共 29 条
[1]   Dose calculation on cone beam CT (CBCT) [J].
Chi, Y. ;
Wu, Q. ;
Yan, D. .
MEDICAL PHYSICS, 2007, 34 (06) :2438-2438
[2]   AN ELECTRON-DENSITY CALIBRATION PHANTOM FOR CT-BASED TREATMENT PLANNING COMPUTERS [J].
CONSTANTINOU, C ;
HARRINGTON, JC ;
DEWERD, LA .
MEDICAL PHYSICS, 1992, 19 (02) :325-327
[3]  
DEPUYDT T, 2006, RADIOTHERAPY ONCO S1, V81, P29
[4]  
Elekta, 2006, CLIN US MAN 16 R3 5
[5]   Conventionally-fractionated image-guided intensity modulated radiotherapy (IG-IMRT): a safe and effective treatment for cancer spinal metastasis [J].
Gong, Youling ;
Wang, Jin ;
Bai, Sen ;
Jiang, Xiaoqin ;
Xu, Feng .
RADIATION ONCOLOGY, 2008, 3 (1)
[6]   Cone-beam CT based image-guidance for extracranial stereotactic radiotherapy of intrapulmonary tumors [J].
Guckenberger, Matthias ;
Meyer, Juergen ;
Wilbert, Juergen ;
Baier, Kurt ;
Mueller, Gerd ;
Wulf, Joern ;
Flentje, Michael .
ACTA ONCOLOGICA, 2006, 45 (07) :897-906
[7]   Quantitative evaluation of cone beam CT data used for treatment planning [J].
Houser, C. ;
Nawaz, A. O. ;
Galvin, J. ;
Xiao, Y. .
MEDICAL PHYSICS, 2006, 33 (06) :2285-2286
[8]   Flat-panel cone-beam computed tomography for image-guided radiation therapy [J].
Jaffray, DA ;
Siewerdsen, JH ;
Wong, JW ;
Martinez, AA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05) :1337-1349
[9]   Inter- and intrafractional movement of the tumour in extracranial stereotactic radiotherapy of NSCLC [J].
Jensen, Henrik R. ;
Hansen, Olfred ;
Hjelm-Hansen, Mogens ;
Brink, Carsten .
ACTA ONCOLOGICA, 2008, 47 (07) :1432-1437
[10]   Retrospective IMRT dose reconstruction based on cone-beam CT and MLC log-file [J].
Lee, Louis ;
Le, Quynh-Thu ;
Xing, Lei .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (02) :634-644