Determination of three nitroimidazoles in rabbit plasma by two-step stacking in capillary zone electrophoresis featuring sweeping and micelle to solvent stacking

被引:19
作者
Yang, Xiupei [1 ]
Cheng, Xiumei [1 ]
Lin, Yingyun [1 ]
Tan, Zhijing [1 ]
Xie, Linxiang [1 ]
Choi, Martin M. F. [2 ]
机构
[1] China West Normal Univ, Coll Chem & Chem Engn, Chem Synth & Pollut Control Key Lab Sichuan Prov, Nanchong 637000, Peoples R China
[2] Hong Kong Baptist Univ, Dept Chem, Kowloon Tong, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
Nitroimidazole; Sweeping; Micelle to solvent stacking; Capillary electrophoresis; Rabbit plasma; ONLINE SAMPLE PRECONCENTRATION; CORRESPONDING HYDROXY METABOLITES; GAS-CHROMATOGRAPHY; POULTRY MEAT; RAPID METHOD; CONFIRMATION; RESIDUES; ANALYTES; METRONIDAZOLE; VALIDATION;
D O I
10.1016/j.chroma.2013.11.053
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study reports a sweeping and micelle to solvent stacking (MSS) method for fast stacking of nitroimidazoles in capillary zone electrophoresis (CZE). The optimal experimental conditions are run buffer of 25 mM sodium phosphate (pH 1.5) and 0.50% (v/v) methanol, micellar solution of 30 mM sodium dodecyl sulfate, applied voltage of 28 kV, and sample and micellar solution injection of 100 s. By applying this new on-line preconcentration technique, the nitroimidazoles content can be determined within 9 min with the limit of detection (SIN = 3) ranging 2.3-3.0 ng/mL, which is lower than that of conventional CZE analysis. The proposed MSS technique affords 20-, 12- and 38-fold improvements in sensitivity for the detection of dimetridazole, metronidazole and secnidazole, respectively. The relative standard deviations (RSDs) of intra-day and inter-day are 2.1-3.6% and 2.7-4.6% (n = 6), respectively. The recoveries in pretreated rabbit plasma at spiked levels of 5.0-10.0 mu g/mL are 92.0-101.1% with RSDs lower than 3.4%. The proposed sweeping and MSS-CZE is a highly sensitive method for the detection of nitroimidazoles in biological and clinical samples and has been successfully applied to analyze nitroimidazoles in pretreated rabbit plasma. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:227 / 233
页数:7
相关论文
共 46 条
  • [1] Sweeping and new on-line sample preconcentration techniques in capillary electrophoresis
    Aranas, Agnes T.
    Guidote, Armando M., Jr.
    Quirino, Joselito P.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (01) : 175 - 185
  • [2] Voltammetry and determination of metronidazole at a carbon fiber microdisk electrode
    Bartlett, PN
    Ghoneim, E
    El-Hefnawy, G
    El-Hallag, I
    [J]. TALANTA, 2005, 66 (04) : 869 - 874
  • [3] 100 000-fold concentration of anions in capillary zone electrophoresis using electroosmotic flow controlled counterflow isotachophoretic stacking under field amplified conditions
    Breadmore, Michael C.
    Quirino, Joselito P.
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (16) : 6373 - 6381
  • [4] On-line preconcentration strategies for trace analysis of metabolites by capillary electrophoresis
    Britz-McKibbin, P
    Terabe, S
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) : 917 - 934
  • [5] Velocity-difference induced focusing of nucleotides in capillary electrophoresis with a dynamic pH junction
    Britz-McKibbin, P
    Bebault, GM
    Chen, DDY
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (08) : 1729 - 1735
  • [6] Dynamic pH junction-sweeping for on-line focusing of dipeptides in capillary electrophoresis with laser-induced fluorescence detection
    Chen, Ying
    Zhang, Lan
    Cai, Zongwei
    Chen, Guonan
    [J]. ANALYST, 2011, 136 (09) : 1852 - 1858
  • [7] Development and validation of a rapid method for the determination and confirmation of 10 nitroimidazoles in animal plasma using liquid chromatography tandem mass spectrometry
    Cronly, Mark
    Behan, Patrice
    Foley, Barry
    Malone, Edward
    Regan, Liam
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (14-15): : 1494 - 1500
  • [8] Systematic optimization of exhaustive electrokinetic injection combined with micellar sweeping in capillary electrophoresis
    Fang, Ning
    Meng, Pingjia
    Zhang, Hong
    Sun, Ying
    Chen, David D. Y.
    [J]. ANALYST, 2007, 132 (02) : 127 - 134
  • [9] Validation of a method for the detection and confirmation of nitroimidazoles and the corresponding hydroxy metabolites in pig plasma by high performance liquid chromatography-tandem mass spectrometry
    Fraselle, Stephanie
    Derop, Veerle
    Degroodt, Jean-Marie
    Van Loco, Joris
    [J]. ANALYTICA CHIMICA ACTA, 2007, 586 (1-2) : 383 - 393
  • [10] High-performance thin-layer chromatographic method for the fluorescence detection of three nitroimidazole residues in pork and poultry tissue
    Gaugain, M
    Abjean, JP
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1996, 737 (02) : 343 - 346