Evaluation of corneal elevation in eyes with subclinical keratoconus and keratoconus using Galilei double Scheimpflug analyzer

被引:25
作者
Jafarinasab, Mohammad Reza [1 ]
Feizi, Sepehr [1 ]
Karimian, Farid [1 ]
Hasanpour, Hossein [1 ]
机构
[1] Shahid Beheshti Univ Med Sci, Ophthalm Res Ctr, Tehran 16666, Iran
关键词
Corneal surface elevation; Galilei Scheimpflug analyzer; Keratoconus; Subclinical keratoconus; REFRACTIVE SURGERY CANDIDATES; ORBSCAN-II; TOPOGRAPHY; PENTACAM; PARAMETERS; ANTERIOR; INDEXES;
D O I
10.5301/ejo.5000226
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To measure corneal elevations in eyes with subclinical keratoconus and those with keratoconus using the Galilei Scheimpflug analyzer and to determine the optimal corneal elevation cutoff points to maximize sensitivity and specificity in discriminating keratoconus and subclinical keratoconus from normal corneas. METHODS. A total of 136 normal eyes, 23 eyes with subclinical keratoconus, and 51 eyes with keratoconus were enrolled. Maximum anterior and posterior corneal elevation was measured in the central 3-, 5-, and 7-mm zones using the Galilei double Scheimpflug camera. Receiver operating characteristic curves were used to compare the sensitivity and specificity of the measured parameters and to identify optimal cutoff points for discriminating keratoconus and subclinical keratoconus from normal corneas. RESULTS. Mean anterior and posterior corneal elevations in all zones were statistically higher in keratoconus and subclinical keratoconus versus normal corneas. The posterior elevation measurement in the 3-mm zone had the strongest power to distinguish keratoconus from normal. The corresponding figure for the 7-mm zone, however, had the strongest power to distinguish eyes with subclinical keratoconus (area under the curve, 0.98 and 0.92, respectively). Optimal cutoff point for posterior elevation in the 3-mm zone was 18.5 pm for keratoconus (sensitivity, 92%; specificity, 95%). The corresponding figure in the 7-mm zone was 50.5 mu m for subclinical keratoconus (sensitivity, 79.9%; specificity, 94.0%). CONCLUSIONS. Anterior and posterior elevations measured by the Galilei analyzer in the 3-mm zone can effectively discriminate keratoconus from normal corneas. These measurements in the 7-mm zone can be considered to distinguish subclinical keratoconus.
引用
收藏
页码:377 / 384
页数:8
相关论文
共 20 条
[1]  
Ambrosio R, 2003, J REFRACT SURG, V19, P24
[2]   Sensitivity and specificity of posterior corneal elevation measured by Pentacam in discriminating keratoconus/subclinical keratoconus [J].
de Sanctis, Ugo ;
Loiacono, Carlotta ;
Richiardi, Lorenzo ;
Turco, Davide ;
Mutani, Bernardo ;
Grignolo, Federico M. .
OPHTHALMOLOGY, 2008, 115 (09) :1534-1539
[3]   Reproductivity and repeatability of central corneal thickness measurement in keratoconus using the rotating scheimpflug camera and ultrasound pachymetry [J].
De Sanctis, Ugo ;
Missolungi, Alessandro ;
Mutani, Bernardo ;
Richiardi, Lorenzo ;
Grignolo, Federico M. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (05) :712-718
[4]   Corneal elevation indices in normal and keratoconic eyes [J].
Fam, Han-Bor ;
Lim, Kooi-Ling .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (08) :1281-1287
[5]   Higher order wavefront aberrations and topography in early and suspected keratoconus [J].
Jafri, Batool ;
Li, Xiaohui ;
Yang, Huiying ;
Rabinowitz, Yaron S. .
JOURNAL OF REFRACTIVE SURGERY, 2007, 23 (08) :774-781
[6]   Recent advances in ophthalmic anterior segment imaging: a new era for ophthalmic diagnosis? [J].
Konstantopoulos, Aristides ;
Hossain, Parwez ;
Anderson, David F. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (04) :551-557
[7]   Quality of life in Keratoconus [J].
Kymes, SM ;
Walline, JJ ;
Zadnik, K ;
Gordon, MO .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 138 (04) :527-535
[8]   Videokeratographic anomalies in familial keratoconus [J].
Levy, D ;
Hutchings, H ;
Rouland, JF ;
Guell, J ;
Burillon, C ;
Arné, JL ;
Colin, J ;
Laroche, L ;
Montard, M ;
Delbosc, B ;
Aptel, I ;
Ginisty, H ;
Grandjean, H ;
Malecaze, F .
OPHTHALMOLOGY, 2004, 111 (05) :867-874
[9]   Evaluation of Keratometric, Pachymetric, and Elevation Parameters of Keratoconic Corneas With Pentacam [J].
Mihaltz, Kata ;
Kovacs, Illes ;
Takacs, Agnes ;
Nagy, Zoltan Z. .
CORNEA, 2009, 28 (09) :976-980
[10]   Comparative evaluation of refractive surgery candidates with Placido topography, Orbscan II, Pentacam, and Wavefront analysis [J].
Nilforoushan, Mohammad-Reza ;
Speaker, Mark ;
Marmor, Michael ;
Abramson, Jodi ;
Tullo, William ;
Morschauser, Dana ;
Latkany, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (04) :623-631