摘要
This paper experimentally studied flow kinematics and impact pressure of a partially filled liquid sloshing flow produced by the periodic motion of a rectangular tank. The study focused on quantifying the flow velocities and impact pressures induced by the flow. Filled with water at a 30 % filling ratio, the tank oscillated at a resonant frequency and generated the violent sloshing flow. The flow propagated like breaking waves that plunged on both side walls and formed up-rushing jets that impacted on the top wall. Velocities of the multiphase flow were measured using the bubble image velocimetry technique. A total of 15 pressure sensors were mounted on the top wall and a side wall to measure the impact pressures. The local kinetic energy obtained by the measured local velocities was used to correlate with the corresponding pressures and determine the impact coefficient. In the sloshing flow, the flow direction was dominantly horizontal in the same direction of the tank motion before the wave crest broke and impinged on a side wall. At this stage, the maximum flow velocities reached 1.6C with C being the wave phase speed. After the wave impingement, the uprising jet moved in the vertical direction with a maximum velocity reached 3.6C before it impacted on the top wall. It was observed that the impact coefficients differed by almost one order of magnitude between the side wall impact and the top wall impact, mainly due to the large difference between the local velocities. A nearly constant impact coefficient was found for both side wall and top wall impacts if the impact pressures were directly correlated with the flow kinetic energy calculated using C instead of the local velocities.
引用
收藏
页数:20
相关论文
共 67 条
[1]  
Abramson H.N., 1963, App. Mechs. Rev, P501
[2]   Experimental investigation of pressure distribution on a rectangular tank due to the liquid sloshing [J].
Akyildiz, H ;
Ünal, E .
OCEAN ENGINEERING, 2005, 32 (11-12) :1503-1516
[3]   Sloshing in a three-dimensional rectangular tank:: Numerical simulation and experimental validation [J].
Akyildiz, Hakan ;
Uenal, N. Erdem .
OCEAN ENGINEERING, 2006, 33 (16) :2135-2149
[4]  
[Anonymous], 1998, P 7 INT C NUM SHIP H
[5]   Green water impact pressure on a three-dimensional model structure [J].
Ariyarathne, Kusalika ;
Chang, Kuang-An ;
Mercier, Richard .
EXPERIMENTS IN FLUIDS, 2012, 53 (06) :1879-1894
[6]   On the analysis of sloshing of water in rectangular containers: Numerical study and experimental validation [J].
Armenio, V ;
LaRocca, M .
OCEAN ENGINEERING, 1996, 23 (08) :705-739
[7]  
Bagnold R.A., 1939, INTERIM REPORT WAVE
[8]   MODELING CRITERIA FOR SCALED LNG SLOSHING EXPERIMENTS [J].
BASS, RL ;
BOWLES, EB ;
TRUDELL, RW ;
NAVICKAS, J ;
PECK, JC ;
YOSHIMURA, N ;
ENDO, S ;
POTS, BFM .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1985, 107 (02) :272-280
[9]   Experimental investigation and numerical modelling of steep forced water waves [J].
Bredmose, H ;
Brocchini, M ;
Peregrine, DH ;
Thais, L .
JOURNAL OF FLUID MECHANICS, 2003, 490 :217-249
[10]   Violent breaking wave impacts. Part 2: modelling the effect of air [J].
Bredmose, H. ;
Peregrine, D. H. ;
Bullock, G. N. .
JOURNAL OF FLUID MECHANICS, 2009, 641 :389-430