Ablation of atrial fibrillation with cryoballoon or duty-cycled radiofrequency pulmonary vein ablation catheter: a randomized controlled study comparing the clinical outcome and safety; the AF-COR study

被引:56
作者
Malmborg, Helena [1 ]
Lonnerholm, Stefan [1 ]
Blomstrom, Per [1 ]
Blomstrom-Lundqvist, Carina [1 ]
机构
[1] Uppsala Univ, Dept Cardiol, Dept Med Sci, SE-75185 Uppsala, Sweden
来源
EUROPACE | 2013年 / 15卷 / 11期
关键词
Catheter ablation; Atrial fibrillation; Cryoballoon; PVAC; Phased RF; Quality of life; QUALITY-OF-LIFE; FOLLOW-UP; UNIPOLAR RADIOFREQUENCY; ENERGY; RECURRENCE; EFFICACY; BIPOLAR;
D O I
10.1093/europace/eut104
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The urge to facilitate the atrial fibrillation (AF) ablation procedure has led to the development of new ablation catheters specifically designed as one-shot tools for pulmonary vein isolation (PVI). The purpose of this study was to compare the efficacy, safety, and procedure times for two such catheters using different energy sources. One hundred and ten patients, referred for ablation of paroxysmal or persistent AF, were randomized to treatment with either the cryoballoon or the circular multipolar duty-cycled radiofrequency-based pulmonary vein ablation catheter (PVAC). Complete PVI was achieved in 98 vs. 93 patients in the cryoballoon and PVAC group, respectively, with complication rates of 8 vs. 2 (P 0.2). Complete freedom from AF, without antiarrhythmic drugs, after one single ablation procedure was seen in 46 in the cryoballoon vs. 34 after 12 months (P 0.2). Procedure times were comparable, but fluoroscopy time was shorter for the cryoballoon (32 16 min) than for the PVAC procedures (47 17 min) (P 0.001). A significant improvement of quality of life (QoL) and arrhythmia-related symptoms was seen in both groups after ablation. Both catheters proved comparably effective and safe in achieving acute PVI, apart from the shorter fluoroscopy times achieved with the cryoballoon. At follow-up, there was no statistically significant difference between the groups regarding freedom from AF and clinical success. The QoL increased to the same levels as for the general Swedish population in both groups.
引用
收藏
页码:1567 / 1573
页数:7
相关论文
共 50 条
[41]   Catheter ablation of atrial fibrillation and atrial tachycardia in patients with pulmonary hypertension: a randomized study [J].
Havranek, Stepan ;
Fingrova, Zdenka ;
Skala, Tomas ;
Reichenbach, Adrian ;
Dusik, Milan ;
Jansa, Pavel ;
Ambroz, David ;
Dytrych, Vladimir ;
Klimes, Dalibor ;
Hutyra, Martin ;
Kautzner, Josef ;
Linhart, Ales ;
Wichterle, Dan .
EUROPACE, 2023, 25 (05)
[42]   Cryoballoon antral pulmonary vein isolation vs contact force-sensing radiofrequency catheter ablation for pulmonary vein and posterior left atrial isolation in patients with persistent atrial fibrillation [J].
Yokokawa, Miki ;
Chugh, Aman ;
Latchamsetty, Rakesh ;
Ghanbari, Hamid ;
Crawford, Thomas ;
Jongnarangsin, Krit ;
Cunnane, Ryan ;
Saeed, Mohammed ;
Sunkara, Bipin ;
Tezcan, Mehmet ;
Bogun, Frank ;
Pelosi, Frank, Jr. ;
Morady, Fred ;
Oral, Hakan .
HEART RHYTHM, 2018, 15 (12) :1835-1841
[43]   Comparing cryoballoon and contact-force guided radiofrequency ablation in pulmonary vein isolation for atrial fibrillation in patients with hypertrophic cardiomyopathy [J].
Kinjo, Takahiko ;
Kimura, Masaomi ;
Horiuchi, Daisuke ;
Itoh, Taihei ;
Ishida, Yuji ;
Nishizaki, Kimitaka ;
Toyama, Yuichi ;
Hamaura, Shogo ;
Sasaki, Shingo ;
Tomita, Hirofumi .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (07) :1635-1645
[44]   Point-by-Point Radiofrequency Ablation Versus the Cryoballoon or a Novel Combined Approach: A Randomized Trial Comparing 3 Methods of Pulmonary Vein Isolation for Paroxysmal Atrial Fibrillation (The Cryo Versus RF Trial) [J].
Hunter, Ross J. ;
Baker, Victoria ;
Finlay, Malcolm C. ;
Duncan, Edward R. ;
Lovell, Matthew J. ;
Tayebjee, Muzahir H. ;
Ullah, Waqas ;
Siddiqui, M. Shoaib ;
McLean, Ailsa ;
Richmond, Laura ;
Kirkby, Claire ;
Ginks, Matthew R. ;
Dhinoja, Mehul ;
Sporton, Simon ;
Earley, Mark J. ;
Schilling, Richard J. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (12) :1307-1314
[45]   A multicenter prospective randomized study comparing the incidence of periprocedural cerebral embolisms caused by catheter ablation of atrial fibrillation between cryoballoon and radiofrequency ablation (Embo-Abl study): Study design [J].
Miyamoto, Koji ;
Kanaoka, Koshiro ;
Ohta, Yasutoshi ;
Yoh, Masue ;
Takahashi, Hiroki ;
Tonegawa-Kuji, Rena ;
Miyazaki, Yuichiro ;
Shimamoto, Keiko ;
Wakamiya, Akinori ;
Ueda, Nobuhiko ;
Nakajima, Kenzaburo ;
Kamakura, Tsukasa ;
Wada, Mitsuru ;
Ishibashi, Kohei ;
Inoue, Yuko ;
Nagase, Satoshi ;
Aiba, Takeshi ;
Narai, Akihisa ;
Nakase, Tomohiro ;
Koga, Masatoshi ;
Fukuda, Tetsuya ;
Kataoka, Naoya ;
Takagi, Masahiko ;
Kusano, Kengo .
CLINICAL CARDIOLOGY, 2023, 46 (02) :214-222
[46]   Catheter Versus Surgical Ablation of Atrial Fibrillation After a Failed Initial Pulmonary Vein Isolation Procedure: A Randomized Controlled Trial [J].
Pokushalov, Evgeny ;
Romanov, Alexander ;
Elesin, Dmitry ;
Bogachev-Prokophiev, Alexander ;
Losik, Denis ;
Bairamova, Sevda ;
Karaskov, Alexander ;
Steinberg, Jonathan S. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (12) :1338-1343
[47]   Effect of Pulmonary Vein Anatomy and Left Atrial Dimensions on Outcome of Circumferential Radiofrequency Catheter Ablation for Atrial Fibrillation [J].
den Uijl, Dennis W. ;
Tops, Laurens F. ;
Delgado, Victoria ;
Schuijf, Joanne D. ;
Kroft, Lucia J. M. ;
de Roos, Albert ;
Boersma, Eric ;
Trines, Serge A. ;
Zeppenfeld, Katja ;
Schalij, Martin J. ;
Bax, Jeroen J. .
AMERICAN JOURNAL OF CARDIOLOGY, 2011, 107 (02) :243-249
[48]   Efficacy and safety of radiofrequency ablation versus cryoballoon ablation for persistent atrial fibrillation: a systematic review and meta-analysis of randomized controlled trials [J].
Amin, Ahmed Mazen ;
Nawlo, Ahmad ;
Ibrahim, Ahmed A. ;
Hassan, Ahmed ;
Saber, Alhassan ;
Abuelazm, Mohamed ;
Abdelazeem, Basel .
EGYPTIAN HEART JOURNAL, 2024, 76 (01)
[49]   The impact of left atrium size on selection of the pulmonary vein isolation method for atrial fibrillation: Cryoballoon or radiofrequency catheter ablation [J].
Ikenouchi, Takashi ;
Inaba, Osamu ;
Takamiya, Tomomasa ;
Inamura, Yukihiro ;
Sato, Akira ;
Matsumura, Yutaka ;
Sato, Hiroyuki ;
Hirakawa, Akihiro ;
Takahashi, Yoshihide ;
Goya, Masahiko ;
Sasano, Tetsuo ;
Nitta, Junichi .
AMERICAN HEART JOURNAL, 2021, 231 :82-92
[50]   Catheter Ablation of Atrial Fibrillation: Long-Term Follow-Up Results of Radiofrequency Catheter Ablation for Redo Procedures After Pulmonary Vein Isolation With the Cryoballoon Technique [J].
Kettering, Klaus ;
Gramley, Felix .
CIRCULATION, 2013, 128 (22)