Ablation of atrial fibrillation with cryoballoon or duty-cycled radiofrequency pulmonary vein ablation catheter: a randomized controlled study comparing the clinical outcome and safety; the AF-COR study

被引:56
作者
Malmborg, Helena [1 ]
Lonnerholm, Stefan [1 ]
Blomstrom, Per [1 ]
Blomstrom-Lundqvist, Carina [1 ]
机构
[1] Uppsala Univ, Dept Cardiol, Dept Med Sci, SE-75185 Uppsala, Sweden
来源
EUROPACE | 2013年 / 15卷 / 11期
关键词
Catheter ablation; Atrial fibrillation; Cryoballoon; PVAC; Phased RF; Quality of life; QUALITY-OF-LIFE; FOLLOW-UP; UNIPOLAR RADIOFREQUENCY; ENERGY; RECURRENCE; EFFICACY; BIPOLAR;
D O I
10.1093/europace/eut104
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The urge to facilitate the atrial fibrillation (AF) ablation procedure has led to the development of new ablation catheters specifically designed as one-shot tools for pulmonary vein isolation (PVI). The purpose of this study was to compare the efficacy, safety, and procedure times for two such catheters using different energy sources. One hundred and ten patients, referred for ablation of paroxysmal or persistent AF, were randomized to treatment with either the cryoballoon or the circular multipolar duty-cycled radiofrequency-based pulmonary vein ablation catheter (PVAC). Complete PVI was achieved in 98 vs. 93 patients in the cryoballoon and PVAC group, respectively, with complication rates of 8 vs. 2 (P 0.2). Complete freedom from AF, without antiarrhythmic drugs, after one single ablation procedure was seen in 46 in the cryoballoon vs. 34 after 12 months (P 0.2). Procedure times were comparable, but fluoroscopy time was shorter for the cryoballoon (32 16 min) than for the PVAC procedures (47 17 min) (P 0.001). A significant improvement of quality of life (QoL) and arrhythmia-related symptoms was seen in both groups after ablation. Both catheters proved comparably effective and safe in achieving acute PVI, apart from the shorter fluoroscopy times achieved with the cryoballoon. At follow-up, there was no statistically significant difference between the groups regarding freedom from AF and clinical success. The QoL increased to the same levels as for the general Swedish population in both groups.
引用
收藏
页码:1567 / 1573
页数:7
相关论文
共 50 条
[31]   Multicenter Prospective Randomized Study Comparing the Incidence of Periprocedural Cerebral Embolisms Caused by Catheter Ablation of Atrial Fibrillation Between Cryoballoon and Radiofrequency Ablation (Embo-Abl Study) [J].
Miyamoto, Koji ;
Kanaoka, Koshiro ;
Ohta, Yasutoshi ;
Yoh, Masue ;
Takahashi, Hiroki ;
Tonegawa-Kuji, Rena ;
Miyazaki, Yuichiro ;
Wakamiya, Akinori ;
Ueda, Nobuhiko ;
Nakajima, Kenzaburo ;
Kamakura, Tsukasa ;
Wada, Mitsuru ;
Ishibashi, Kohei ;
Inoue-Yamada, Yuko ;
Nagase, Satoshi ;
Aiba, Takeshi ;
Ichikawa, Hironobu ;
Narai, Akihisa ;
Nakase, Tomohiro ;
Koga, Masatoshi ;
Fukuda, Tetsuya ;
Kataoka, Naoya ;
Takagi, Masahiko ;
Kusano, Kengo .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2024, 17 (08) :e012952
[32]   Effect of cryoballoon and radiofrequency ablation for pulmonary vein isolation on left atrial function in patients with nonvalvular paroxysmal atrial fibrillation: A prospective randomized study (Cryo-LAEF study) [J].
Giannopoulos, Georgios ;
Kossyvakis, Charalampos ;
Vrachatis, Dimitrios ;
Aggeli, Constadina ;
Tsitsinakis, Georgios ;
Letsas, Konstantinos ;
Tsiachris, Dimitrios ;
Tsoukala, Styliani ;
Efremidis, Michalis ;
Katritsis, Dimosthenis ;
Deftereos, Spyridon .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (07) :991-998
[33]   Randomized, Controlled Trial of the Safety and Effectiveness of a Contact Force-Sensing Irrigated Catheter for Ablation of Paroxysmal Atrial Fibrillation Results of the TactiCath Contact Force Ablation Catheter Study for Atrial Fibrillation (TOCCASTAR) Study [J].
Reddy, Vivek Y. ;
Dukkipati, Srinivas R. ;
Neuzil, Petr ;
Natale, Andrea ;
Albenque, Jean-Paul ;
Kautzner, Josef ;
Shah, Dipen ;
Michaud, Gregory ;
Wharton, Marcus ;
Harari, David ;
Mahapatra, Srijoy ;
Lambert, Hendrik ;
Mansour, Moussa .
CIRCULATION, 2015, 132 (10) :907-915
[34]   Randomized Comparison of Multipolar, Duty-Cycled, Bipolar-Unipolar Radiofrequency Versus Conventional Catheter Ablation for Treatment of Common Atrial Flutter [J].
Erdogan, Ali ;
Guettler, Norbert ;
Doerr, Oliver ;
Franzen, Wolfgang ;
Soydan, Nedim ;
Bilgin, Mehmet ;
Vogelsang, Pascal ;
Parahuleva, Mariana ;
Tillmanns, Harald ;
Stracke, Siegbert ;
Guenduez, Dursun ;
Neuhof, Christiane .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2010, 21 (10) :1109-1113
[35]   The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study [J].
Reddy, Vivek Y. ;
Shah, Dipen ;
Kautzner, Josef ;
Schmidt, Boris ;
Saoudi, Nadir ;
Herrera, Claudia ;
Jais, Pierre ;
Hindricks, Gerhard ;
Peichl, Petr ;
Yulzari, Aude ;
Lambert, Hendrik ;
Neuzil, Petr ;
Natale, Andrea ;
Kuck, Karl-Heinz .
HEART RHYTHM, 2012, 9 (11) :1789-1795
[36]   Cryoballoon versus radiofrequency catheter ablation of paroxysmal atrial fibrillation: Biomarkers of myocardial injury, recurrence rates, and pulmonary vein reconnection patterns [J].
Kuehne, Michael ;
Suter, Yves ;
Altmann, David ;
Ammann, Peter ;
Schaer, Beat ;
Osswald, Stefan ;
Sticherling, Christian .
HEART RHYTHM, 2010, 7 (12) :1770-1776
[37]   Cryoballoon Versus Open Irrigated Radiofrequency Ablation in Patients With Paroxysmal Atrial Fibrillation The Prospective, Randomized, Controlled, Noninferiority FreezeAF Study [J].
Luik, Armin ;
Radzewitz, Andrea ;
Kieser, Meinhard ;
Walter, Marlene ;
Bramlage, Peter ;
Hoermann, Patrick ;
Schmidt, Kerstin ;
Horn, Nicolas ;
Brinkmeier-Theofanopoulou, Maria ;
Kunzmann, Kevin ;
Riexinger, Tobias ;
Schymik, Gerhard ;
Merkel, Matthias ;
Schmitt, Claus .
CIRCULATION, 2015, 132 (14) :1311-1319
[38]   Rationale and Design of FIRE AND ICE: A Multicenter Randomized Trial Comparing Efficacy and Safety of Pulmonary Vein Isolation Using a Cryoballoon versus Radiofrequency Ablation with 3D-Reconstruction [J].
Fuernkranz, Alexander ;
Brugada, Josep ;
Albenque, Jean-Paul ;
Tondo, Claudio ;
Bestehorn, Kurt ;
Wegscheider, Karl ;
Ouyang, Feifan ;
Kuck, Karl-Heinz .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (12) :1314-1320
[39]   Cryoballoon Ablation versus Radiofrequency Ablation in Patients with Persistent Atrial Fibrillation (CRRF-PeAF): Protocol for a Prospective, Multicenter, Randomized, Controlled Study [J].
Miyamoto, Koji ;
Kanaoka, Koshiro ;
Yoh, Masue ;
Takahashi, Hiroki ;
Kishihara, Jun ;
Ishikura, Masahiro ;
Sasaki, Yasuhiro ;
Fukunaga, Hiroshi ;
Nagase, Takahiko ;
Asano, So ;
Mizuno, Shingo ;
Yamagami, Shintaro ;
Yazaki, Yoshinao ;
Kusume, Takahiro ;
Takada, Yasuyuki ;
Yodogawa, Kenji ;
Shimizu, Wataru ;
Shigeta, Takatoshi ;
Sagawa, Yuichiro ;
Inoue, Yuko ;
Nagase, Satoshi ;
Aiba, Takeshi ;
Takagi, Masahiko ;
Fukaya, Hidehira ;
Kobori, Atsushi ;
Nitta, Junichi ;
Murakami, Masato ;
Nishiuchi, Suguru ;
Satomi, Kazuhiro ;
Kataoka, Naoya ;
Iwasaki, Yu-Ki ;
Ashikaga, Keiichi ;
Yamauchi, Yasuteru ;
Kusano, Kengo .
IJC HEART & VASCULATURE, 2022, 41
[40]   Mesh ablator vs. cryoballoon pulmonary vein ablation of symptomatic paroxysmal atrial fibrillation: results of the MACPAF study [J].
Koch, Lydia ;
Haeusler, Karl Georg ;
Herm, Juliane ;
Safak, Erdal ;
Fischer, Robert ;
Malzahn, U. ;
Wernckes, Thomas ;
Heuschmann, Peter U. ;
Endres, Matthias ;
Fiebach, Jochen B. ;
Schultheiss, Heinz-Peter ;
Schirdewan, Alexander .
EUROPACE, 2012, 14 (10) :1441-1449