Ablation of atrial fibrillation with cryoballoon or duty-cycled radiofrequency pulmonary vein ablation catheter: a randomized controlled study comparing the clinical outcome and safety; the AF-COR study

被引:56
作者
Malmborg, Helena [1 ]
Lonnerholm, Stefan [1 ]
Blomstrom, Per [1 ]
Blomstrom-Lundqvist, Carina [1 ]
机构
[1] Uppsala Univ, Dept Cardiol, Dept Med Sci, SE-75185 Uppsala, Sweden
来源
EUROPACE | 2013年 / 15卷 / 11期
关键词
Catheter ablation; Atrial fibrillation; Cryoballoon; PVAC; Phased RF; Quality of life; QUALITY-OF-LIFE; FOLLOW-UP; UNIPOLAR RADIOFREQUENCY; ENERGY; RECURRENCE; EFFICACY; BIPOLAR;
D O I
10.1093/europace/eut104
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The urge to facilitate the atrial fibrillation (AF) ablation procedure has led to the development of new ablation catheters specifically designed as one-shot tools for pulmonary vein isolation (PVI). The purpose of this study was to compare the efficacy, safety, and procedure times for two such catheters using different energy sources. One hundred and ten patients, referred for ablation of paroxysmal or persistent AF, were randomized to treatment with either the cryoballoon or the circular multipolar duty-cycled radiofrequency-based pulmonary vein ablation catheter (PVAC). Complete PVI was achieved in 98 vs. 93 patients in the cryoballoon and PVAC group, respectively, with complication rates of 8 vs. 2 (P 0.2). Complete freedom from AF, without antiarrhythmic drugs, after one single ablation procedure was seen in 46 in the cryoballoon vs. 34 after 12 months (P 0.2). Procedure times were comparable, but fluoroscopy time was shorter for the cryoballoon (32 16 min) than for the PVAC procedures (47 17 min) (P 0.001). A significant improvement of quality of life (QoL) and arrhythmia-related symptoms was seen in both groups after ablation. Both catheters proved comparably effective and safe in achieving acute PVI, apart from the shorter fluoroscopy times achieved with the cryoballoon. At follow-up, there was no statistically significant difference between the groups regarding freedom from AF and clinical success. The QoL increased to the same levels as for the general Swedish population in both groups.
引用
收藏
页码:1567 / 1573
页数:7
相关论文
共 50 条
[21]   Conduction recovery in patients with recurrent atrial fibrillation after pulmonary vein isolation using multi-electrode duty cycled radiofrequency ablation [J].
Balt, J. C. ;
Karadavut, S. ;
Mulder, A. A. W. ;
Luermans, J. G. L. M. ;
Wijffels, M. C. E. F. ;
Boersma, L. V. A. .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2013, 37 (02) :197-204
[22]   Pulmonary vein volume predicts the outcome of radiofrequency catheter ablation of paroxysmal atrial fibrillation [J].
Shimamoto, Keiko ;
Miura, Fumiharu ;
Shimatani, Yuji ;
Nishioka, Kenji ;
Inoue, Ichiro .
PLOS ONE, 2018, 13 (07)
[23]   Safety and efficacy of multipolar pulmonary vein ablation catheter vs. irrigated radiofrequency ablation for paroxysmal atrial fibrillation: a randomized multicentre trial [J].
McCready, J. ;
Chow, A. W. ;
Lowe, M. D. ;
Segal, O. R. ;
Ahsan, S. ;
de Bono, J. ;
Dhaliwal, M. ;
Mfuko, C. ;
Ng, A. ;
Rowland, E. R. ;
Bradley, R. J. W. ;
Paisey, J. ;
Roberts, P. ;
Morgan, J. M. ;
Sandilands, A. ;
Yue, A. ;
Lambiase, P. D. .
EUROPACE, 2014, 16 (08) :1145-1153
[24]   Pulmonary vein re-isolation for atrial fibrillation using duty-cycled phased radiofrequency ablation: safety and efficacy of a primary 2:1 bipolar/unipolar ablation mode [J].
Marcus Wieczorek ;
Reinhard Hoeltgen ;
Shahram Tajtaraghi ;
Wolfgang Lawrenz ;
Michael Lukat .
Journal of Interventional Cardiac Electrophysiology, 2013, 36 :55-60
[25]   Cryoballoon vs. radiofrequency ablation for atrial fibrillation: a study of outcome and safety based on the ESC-EHRA atrial fibrillation ablation long-term registry and the Swedish catheter ablation registry [J].
Mortsell, David ;
Arbelo, Elena ;
Dagres, Nikolaos ;
Brugada, Josep ;
Laroche, Cecile ;
Trines, Serge A. ;
Malmborg, Helena ;
Hoglund, Niklas ;
Tavazzi, Luigi ;
Pokushalov, Evgeny ;
Stabile, Giuseppe ;
Blomstrom-Lundqvist, Carina .
EUROPACE, 2019, 21 (04) :581-589
[26]   Efficacy and safety of novel temperature-controlled radiofrequency ablation system during pulmonary vein isolation in patients with paroxysmal atrial fibrillation: TRAC-AF study [J].
Starek, Zdenek ;
Lehar, Frantisek ;
Jez, Jiri ;
Pesl, Martin ;
Neuzil, Petr ;
Sediva, Lucie ;
Petru, Jan ;
Dujka, Libor ;
Funasako, Moritoshi ;
Kautzner, Josef ;
Peichl, Petr ;
Aldhoon, Bashar ;
Albenque, Jean-Paul ;
Combes, Stephane ;
Boveda, Serge ;
Dukkipati, Srinivas R. ;
Reddy, Vivek Y. .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 64 (02) :375-381
[27]   Pulmonary vein reconnection predicts good clinical outcome after second catheter ablation for atrial fibrillation [J].
Kim, Tae-Hoon ;
Parke, Junbeom ;
Uhm, Jae -Sun ;
Joung, Boyoung ;
Lee, Moon-Hyoung ;
Pak, Hui-Nam .
EUROPACE, 2017, 19 (06) :961-967
[28]   A multicenter study comparing the outcome of catheter ablation of atrial fibrillation between cryoballoon and radiofrequency ablation in patients with heart failure (CRABL-HF): Study design [J].
Miyamoto, Koji ;
Hasegawa, Kanae ;
Takahashi, Hiroki ;
Masue, Yoh ;
Kataoka, Naoya ;
Fukuzawa, Koji ;
Ashikaga, Keiichi ;
Noda, Takashi ;
Satomi, Kazuhiro ;
Tada, Hiroshi ;
Takagi, Masahiko ;
Yasuda, Satoshi ;
Kusano, Kengo .
JOURNAL OF ARRHYTHMIA, 2020, 36 (03) :449-455
[29]   A comparative study of pericardial effusion and pleural effusion after cryoballoon ablation or radiofrequency catheter ablation of atrial fibrillation [J].
Xiao, Fang Yi ;
Ju, Wei Zhu ;
Chen, Hong Wu ;
Huang, Wei Jian ;
Chen, Minglong .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (05) :1062-1067
[30]   Pulmonary vein isolation by duty-cycled bipolar and unipolar antrum ablation using a novel multielectrode ablation catheter system: first clinical results [J].
Marcus Wieczorek ;
Reinhard Hoeltgen ;
Martin Brueck ;
Dirk Bandorski ;
Elvan Akin ;
Ali Reza Salili .
Journal of Interventional Cardiac Electrophysiology, 2010, 27 :23-31