Ablation of atrial fibrillation with cryoballoon or duty-cycled radiofrequency pulmonary vein ablation catheter: a randomized controlled study comparing the clinical outcome and safety; the AF-COR study

被引:53
|
作者
Malmborg, Helena [1 ]
Lonnerholm, Stefan [1 ]
Blomstrom, Per [1 ]
Blomstrom-Lundqvist, Carina [1 ]
机构
[1] Uppsala Univ, Dept Cardiol, Dept Med Sci, SE-75185 Uppsala, Sweden
来源
EUROPACE | 2013年 / 15卷 / 11期
关键词
Catheter ablation; Atrial fibrillation; Cryoballoon; PVAC; Phased RF; Quality of life; QUALITY-OF-LIFE; FOLLOW-UP; UNIPOLAR RADIOFREQUENCY; ENERGY; RECURRENCE; EFFICACY; BIPOLAR;
D O I
10.1093/europace/eut104
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The urge to facilitate the atrial fibrillation (AF) ablation procedure has led to the development of new ablation catheters specifically designed as one-shot tools for pulmonary vein isolation (PVI). The purpose of this study was to compare the efficacy, safety, and procedure times for two such catheters using different energy sources. One hundred and ten patients, referred for ablation of paroxysmal or persistent AF, were randomized to treatment with either the cryoballoon or the circular multipolar duty-cycled radiofrequency-based pulmonary vein ablation catheter (PVAC). Complete PVI was achieved in 98 vs. 93 patients in the cryoballoon and PVAC group, respectively, with complication rates of 8 vs. 2 (P 0.2). Complete freedom from AF, without antiarrhythmic drugs, after one single ablation procedure was seen in 46 in the cryoballoon vs. 34 after 12 months (P 0.2). Procedure times were comparable, but fluoroscopy time was shorter for the cryoballoon (32 16 min) than for the PVAC procedures (47 17 min) (P 0.001). A significant improvement of quality of life (QoL) and arrhythmia-related symptoms was seen in both groups after ablation. Both catheters proved comparably effective and safe in achieving acute PVI, apart from the shorter fluoroscopy times achieved with the cryoballoon. At follow-up, there was no statistically significant difference between the groups regarding freedom from AF and clinical success. The QoL increased to the same levels as for the general Swedish population in both groups.
引用
收藏
页码:1567 / 1573
页数:7
相关论文
共 50 条
  • [1] Paroxysmal and persistent atrial fibrillation ablation outcomes with the pulmonary vein ablation catheter GOLD duty-cycled phased radiofrequency ablation catheter: quality of life and 12-month efficacy results from the GOLD Atrial Fibrillation Registry
    Boersma, Lucas
    Kozluk, Edward
    Maglia, Giampiero
    de Sousa, Joao
    Grebe, Olaf
    Eckardt, Lars
    Hokanson, Robert B.
    Hemingway, Lauren A.
    Ostern, Ekaterina
    Park, Hyoung-Seob
    Rovaris, Giovanni
    Arribas, Fernando
    Scharf, Christoph
    Csanadi, Zoltan
    Arenal, Angel
    Laurenzi, Francesco
    Klaver, Martijn
    Goette, Andreas
    EUROPACE, 2020, 22 (06): : 888 - 896
  • [2] Is the Time of Atrial Fibrillation Recurrence After Duty-Cycled Radiofrequency Ablation Affected by the Pattern of Pulmonary Vein Reconnections?
    Wieczorek, Marcus
    Sassani, Kiarash
    Hoeltgen, Reinhard
    CARDIOLOGY RESEARCH, 2020, 11 (03) : 179 - 184
  • [3] European survey on efficacy and safety of duty-cycled radiofrequency ablation for atrial fibrillation
    Scharf, C.
    Ng, G. A.
    Wieczorek, M.
    Deneke, T.
    Furniss, S. S.
    Murray, St.
    Debruyne, Ph.
    Hobson, N.
    Berntsen, R. F.
    Schneider, M. A.
    Hauer, H. A.
    Halimi, F.
    Boveda, S.
    Asbach, S.
    Boesche, L.
    Zimmermann, M.
    Brigadeau, F.
    Taieb, J.
    Merkel, M.
    Pfyffer, M.
    Brunner-La Rocca, H. P.
    Boersma, L. V. A.
    EUROPACE, 2012, 14 (12): : 1700 - 1707
  • [4] Evaluation of stroke incidence with duty-cycled multielectrode-phased radiofrequency ablation of persistent atrial fibrillation results of the VICTORY AF Study
    Hummel, John
    Verma, Atul
    Calkins, Hugh
    Schwamm, Lee H.
    Gress, Daryl
    Wells, Darryl
    Souza, Joseph
    Hokanson, Robert B.
    Hemingway, Lauren
    Stromberg, Kurt
    Hoyt, Robert
    Wickliffe, Andrew
    DeLurgio, David
    Boersma, Lucas
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (06) : 1289 - 1297
  • [5] Comparison of effects on coagulation and inflammatory markers using a duty-cycled bipolar and unipolar radiofrequency pulmonary vein ablation catheter vs. a cryoballoon catheter for pulmonary vein isolation
    Malmborg, Helena
    Christersson, Christina
    Lonnerholm, Stefan
    Blomstrom-Lundqvist, Carina
    EUROPACE, 2013, 15 (06): : 798 - 804
  • [6] Effect of Pulmonary Vein Anatomy and Pulmonary Vein Diameters on Outcome of Cryoballoon Catheter Ablation for Atrial Fibrillation
    Guler, Ekrem
    Guler, Gamze Babur
    Demir, Gultekin Gunhan
    Kizilirmak, Filiz
    Gunes, Haci Murat
    Barutcu, Irfan
    Kilicaslan, Fethi
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (08): : 989 - 996
  • [7] Utility of Esophageal Temperature Monitoring During Pulmonary Vein Isolation for Atrial Fibrillation Using Duty-Cycled Phased Radiofrequency Ablation
    Deneke, Thomas
    Buenz, Kathrin
    Bastian, Annely
    Paesler, Marcus
    Anders, Helge
    Lehmann, Rainer
    Meuser, Wolfgang
    de Groot, Joris R.
    Horlitz, Marc
    Haberkorn, Ron
    Muegge, Andreas
    Shin, Dong-In
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 (03) : 255 - 261
  • [8] Pulmonary vein re-isolation for atrial fibrillation using duty-cycled phased radiofrequency ablation: safety and efficacy of a primary 2:1 bipolar/unipolar ablation mode
    Wieczorek, Marcus
    Hoeltgen, Reinhard
    Tajtaraghi, Shahram
    Lawrenz, Wolfgang
    Lukat, Michael
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2013, 36 (01) : 55 - 60
  • [9] Duty-cycled bipolar/unipolar radiofrequency ablation for symptomatic atrial fibrillation induces significant pulmonary vein narrowing at long-term follow-up
    Compier, Marieke G.
    Leong, Darryl P.
    Marsan, Nina Ajmone
    Delgado, Victoria
    Zeppenfeld, Katja
    Schalij, Martin J.
    Trines, Serge A.
    EUROPACE, 2013, 15 (05): : 690 - 696
  • [10] Correlation of pulmonary vein reconnection patterns after cryoballoon and duty-cycled ablation of atrial fibrillation with the time of arrhythmia recurrence
    Wieczorek, Marcus
    Sassani, Kiarash
    Hoeltgen, Reinhard
    JOURNAL OF ARRHYTHMIA, 2020, 36 (06) : 1051 - 1060