Evaluation of enzyme-based tear glucose electrochemical sensors over a wide range of blood glucose concentrations

被引:72
作者
Peng, Bo [1 ]
Lu, Jing [2 ]
Balijepalli, Anant S. [3 ]
Major, Terry C. [4 ]
Cohan, Bruce E. [5 ]
Meyerhoff, Mark E. [1 ]
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Computat Med & Bioinformat, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[4] Univ Michigan, Dept Surg, Ann Arbor, MI 48109 USA
[5] EyeLab Grp, Ann Arbor, MI 48109 USA
关键词
Tear glucose; Electrochemical sensor; Rabbit model; Blood-tear glucose correlation; DIABETES-MELLITUS; FLUID; COMPLICATIONS; ACCURACY; DYNAMICS;
D O I
10.1016/j.bios.2013.05.014
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Miniature enzyme-based amperometric and coulometric glucose sensors were fabricated and applied to measure tear glucose concentrations in anesthetized rabbits. Without perturbing the eyeball, 3 mu L of tear fluid was sampled from the marginal conjunctiva under the lower eyelid of anesthetized rabbits at various time points via a microliter glass capillary tube, and the miniature sensors were then inserted into the volume of collected tear fluids within the capillaries for detection. Intravenous bolus doses of insulin were administrated to the rabbits to lower the elevated blood glucose concentrations caused by anesthesia over the 7 h test periods. A significant correlation was found between tear and blood glucose levels for multiple rabbits, suggesting that electrochemical sensor-based tear glucose measurements may be a potential supplementary method for point-of-care glucose monitoring. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:204 / 209
页数:6
相关论文
共 39 条
[31]   Catalytic Modification of Porous Two-Dimensional Ni-MOFs on Portable Electrochemical Paper-Based Sensors for Glucose and Hydrogen Peroxide Detection [J].
Yang, Ya ;
Ji, Wenhui ;
Yin, Yutao ;
Wang, Nanxiang ;
Wu, Wanxia ;
Zhang, Wei ;
Pei, Siying ;
Liu, Tianwei ;
Tao, Chao ;
Zheng, Bing ;
Wu, Qiong ;
Li, Lin .
BIOSENSORS-BASEL, 2023, 13 (05)
[32]   Accuracy Evaluation of Four Blood Glucose Monitoring Systems in the Hands of Intended Users and Trained Personnel Based on ISO 15197 Requirements [J].
Freckmann, Guido ;
Baumstark, Annette ;
Jendrike, Nina ;
Rittmeyer, Delia ;
Pleus, Stefan ;
Haug, Cornelia .
DIABETES TECHNOLOGY & THERAPEUTICS, 2017, 19 (04) :246-254
[33]   Evaluation of two point-of-care meters and a portable chemistry analyzer for measurement of blood glucose concentrations in juvenile white-tailed deer (Odocoileus virginianus) [J].
Burdick, Stacy ;
Mitchell, Mark A. ;
Neil, Johanna ;
Heggem, Brittany ;
Whittington, Julia ;
Acierno, Mark J. .
JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2012, 240 (05) :596-599
[34]   Non-Invasive Disposable 2D Ti3C2Tx based Enzyme Free Electrochemical Sweat Glucose Biosensor [J].
Saraswathi, K. A. ;
Reddy, M. Sai Bhargava ;
Jayarambabu, N. ;
Rao, K. Venkateswara ;
Aich, Shampa ;
Rao, T. Venkatappa .
MICROCHEMICAL JOURNAL, 2024, 205
[35]   Evaluation of three point-of-care meters and a portable veterinary chemistry analyzer for measurement of blood glucose concentrations in black-tailed prairie dogs (Cynomys ludovicianus) [J].
Higbie, Christine T. ;
Eshar, David ;
Bello, Nora M. .
AMERICAN JOURNAL OF VETERINARY RESEARCH, 2015, 76 (06) :532-539
[36]   Multicenter Evaluation of a New Strip-Based Blood Glucose System for Point-of-Care Testing in Critical and Non-Critical Care Settings [J].
Goodman, Michael ;
Bercker, Sven ;
Breitenbeck, Nancy ;
Canada-Vilalta, Cristina ;
Canepa, Daisy D. ;
Clarke, William A. ;
Farnsworth, Christopher W. ;
Ganser, Edward O. ;
Geerts, Nienke ;
Goldsmith, Barbara ;
Headden, Gary ;
Hoppensteadt, Debra ;
Klapperich, Birgit ;
Matika, Ryan ;
Miles, Gabrielle ;
Mukhopadhyay, Sagori ;
Nichols, James H. ;
O'Dell, Rebecca M. ;
Rafique, Zubaid ;
Schuetzenmeister, Andre ;
Slingerland, Robbert ;
Stankiewicz, Ann F. ;
Swanson, Jonathan R. ;
Tran, Nam K. ;
Wu, Alan H. B. ;
Karon, Brad S. .
JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2025,
[37]   System accuracy evaluation of 18 CE-marked current-generation blood glucose monitoring systems based on EN ISO 15197:2015 [J].
Pleus, Stefan ;
Baumstark, Annette ;
Jendrike, Nina ;
Mende, Jochen ;
Link, Manuela ;
Zschornack, Eva ;
Haug, Cornelia ;
Freckmann, Guido .
BMJ OPEN DIABETES RESEARCH & CARE, 2020, 8 (01)
[38]   Eco-friendly fabrication of nonenzymatic electrochemical sensor based on cobalt/polymelamine/nitrogen-doped graphitic-porous carbon nanohybrid material for glucose monitoring in human blood [J].
Elancheziyan, Mari ;
Prakasham, Karthikeyan ;
Eswaran, Muthusankar ;
Duraisamy, Murugesan ;
Ganesan, Sivarasan ;
Lee, Siew Ling ;
Ponnusamy, Vinoth Kumar .
ENVIRONMENTAL RESEARCH, 2023, 223
[39]   RETRACTED: Protective and antidiabetic effects of extract from Nigella sativa on blood glucose concentrations against streptozotocin (STZ)-induced diabetic in rats: an experimental study with histopathological evaluation(Retracted article. See vol. 11, 2016) [J].
Alimohammadi, Samad ;
Hobbenaghi, Rahim ;
Javanbakht, Javad ;
Kheradmand, Danial ;
Mortezaee, Reza ;
Tavakoli, Maryam ;
Khadivar, Farshid ;
Akbari, Hamid .
DIAGNOSTIC PATHOLOGY, 2013, 8