Post-combustion capture of CO2 at an integrated steel mill - Part I: Technical concept analysis

被引:76
作者
Arasto, Antti [1 ]
Tsupari, Eemeli [1 ]
Karki, Janne [1 ]
Pisila, Erkki [2 ]
Sorsamaki, Lotta [1 ]
机构
[1] VTT Tech Res Ctr Finland, FI-02044 Espoo, Vtt, Finland
[2] Ruukki Met Oy, Raahe 92100, Finland
关键词
CCS; Iron and steel industry; Post-combustion capture; Blast furnace; Aspen Plus;
D O I
10.1016/j.ijggc.2012.08.018
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study different possibilities for applying post-combustion capture at an integrated steel mill in order to reduce carbon dioxide emissions were studied. Implications of different amounts of CO2 captured, different solvents for post-combustion capture and different heat supply options for solvent regeneration to the energy balance and greenhouse gas emissions of the steel mill are compared to that of the base case for the steel mill. The case study is based on Ruukki Metals Ltd.'s Raahe steel mill that is situated on the coast of the Gulf of Bothnia. It is the largest integrated steel mill in the Nordic countries producing hot rolled steel plates and coils. It is also the largest CO2 point source in Finland emitting approximately 4 Mt/year. Carbon capture processes were modelled using Aspen Plus process modelling software and results were used to estimate the potential for reducing CO2 emissions at an integrated steel mill from a plant operator's point of view. Different heat integration options and heat utilization scenarios were investigated. The heat available for solvent regeneration varied between these heat utilization scenarios and thus partial capture of CO2 was investigated with the CO2 amount captured depending on the heat available for solvent regeneration in the different case studies. The results of the study show a significant CO2 reduction potential using CCS. Approximately 50-75% of the emissions from the site could be captured using post-combustion capture. Capturing a larger amount of emissions would be technically less feasible due to the large number of small stacks around the large, integrated steel mill site. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:271 / 277
页数:7
相关论文
共 14 条
  • [1] CO2 capture from power plants -: Part II.: A parametric study of the economical performance based on mono-ethanolamine
    Abu-Zahra, Mohammad R. M.
    Niederer, John P. M.
    Feron, Paul H. M.
    Versteeg, Geert F.
    [J]. INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2007, 1 (02) : 135 - 142
  • [2] [Anonymous], DOENETL20071281
  • [3] EMV, 2011, EM ALL BAL
  • [4] *EPRI, 2007, REV CO2 CAPT DEV ACT
  • [5] *FORTUM, 2009, APPL CCS FINL SEM 28
  • [6] FORTUM, 2010, ENV IMP ASS CARB CAP
  • [7] IEA, 2008, CO2 CAPT STOR KEY CA
  • [8] Cross-border CO2 infrastructure options for a CCS demonstration in Finland
    Kujanpaa, Lauri
    Rauramo, Joonas
    Arasto, Antti
    [J]. 10TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, 2011, 4 : 2425 - 2431
  • [9] *NETL, 2009, DOENETL401110509
  • [10] Taylor R, 2003, CHEM ENG PROG, V99, P28