Spectrometric determination of the refractive index of optical wave guiding materials used in lab-on-a-chip applications

被引:10
作者
Cardenas-Valencia, AM [1 ]
Dlutowski, J [1 ]
Fries, D [1 ]
Langebrake, L [1 ]
机构
[1] Univ S Florida, Marine Sci Coll, Ctr Ocean Technol, St Petersburg, FL 33626 USA
关键词
refractive index; optical materials; plastics; glasses; visible spectroscopy; instrumental methods;
D O I
10.1366/000370206776342526
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The design and optimization of light-based analytical devices often require optical characterization of materials involved in their construction. With the aim of benefiting lab-on-a-chip applications, a transmission spectrometric method for determining refractive indices, it, of transparent solids is presented here. Angular dependence of the reflection coefficient between material-air interfaces constitutes the basis of the procedure. Firstly, the method is studied via simulation, using a theoretical algorithm that describes the light propagation through the sample slide, to assess the potentially attainable accuracy. Simulations also serve to specify the angles at which measurements should be taken. Secondly, a visible light source and an optical fiber spectrometer are used to perform measurements on three commonly used materials in optical lab-on-a-chip devices. A nonlinear regression subroutine fits experimental data to the proposed theoretical model and is used to obtain it. Because the attainable precision using this method of refractive index determination is dictated by the uncertainty in the transmission measurements, the precision (with 95% confidence) for mechanically rigid samples, namely, glass and poly(methyl methacrylate) (PMMA), is higher than those estimated for the elastomer sample (in-house-molded poly(dimethylsiloxane) (PDMS)). At wavelengths with the highest signal-to-noise ratio for the spectrometer setup, the estimated refractive indices were 1.43 +/- 0.05 (580 nm) for PDMS, 1.54 +/- 0.02 (546 nm) for glass, and 1.485 +/- 0.005 (656 mu) for PMMA. Accurate refractive index estimations with an average precision equal to 0.01 refractive index units (RIU) were obtained for PMMA and glass samples, and an average precision of 0.09 RIU for the PDMS molded slide between 550 and 750 nm was obtained.
引用
收藏
页码:322 / 329
页数:8
相关论文
共 30 条
[1]  
AGEEV LA, 2001, ZH PRIKL SPEKTROSK, V68, P270
[2]   METHOD FOR MEASURING THE REFRACTIVE-INDEX OF TRANSPARENT SOLIDS [J].
BASS, JD ;
WEIDNER, DJ .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1984, 55 (10) :1569-1573
[3]  
Bozlee BJ, 2002, J CHEM EDUC, V79, P619
[4]  
BRANDRUP J, 1989, POLYM HDB
[5]  
CARDENASVALENCI.A, 2004, 2004 P MICR AN SYST, V1, P114
[6]  
CARDENASVALENCI.AM, 2005, IN PRESS SENS ACTU B
[7]   Light emitting diode-based detectors absorbance, fluorescence and spectroelectrochemical measurements in a planar flow-through cell [J].
Dasgupta, PK ;
Eom, IY ;
Morris, KJ ;
Li, JZ .
ANALYTICA CHIMICA ACTA, 2003, 500 (1-2) :337-364
[8]   Determination of optical waveguide refractive-index profiles with the inverse analytic transfer matrix method [J].
Ding, Y ;
Cao, ZQ ;
Shen, QS .
OPTICAL AND QUANTUM ELECTRONICS, 2004, 36 (06) :489-497
[9]  
DLUTOWSKI J, 2005, IN PRESS J CHEM ED
[10]   Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984