Usefulness of slice encoding for metal artifact correction (SEMAC) for reducing metallic artifacts in 3-T MRI

被引:51
作者
Lee, Young Han [1 ,2 ]
Lim, Daekeon [1 ,2 ]
Kim, Eunju [3 ,4 ]
Kim, Sungjun [1 ,2 ]
Song, Ho-Taek [1 ,2 ]
Suh, Jin-Suck [1 ,2 ]
机构
[1] Yonsei Univ, Coll Med, Dept Radiol, Res Inst Radiol Sci,Med Convergence Res Inst, Seoul 120752, South Korea
[2] Yonsei Univ, Coll Med, Severance Biomed Sci Inst, Seoul 120752, South Korea
[3] Philips Healthcare, Seoul, South Korea
[4] Hanyang Univ, Grad Sch Biomed Sci & Engn, Seoul 133791, South Korea
基金
新加坡国家研究基金会;
关键词
Magnetic resonance; Slice encoding for metal artifact correction; Metallic artifacts; SUSCEPTIBILITY; REDUCTION; IMPLANTS;
D O I
10.1016/j.mri.2012.11.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of the study was to assess the usefulness of slice encoding for metal artifact correction (SEMAC) in 3.0-T magnetic resonance (MR) in minimizing metallic artifacts in patients with spinal prostheses. Materials and Methods: Institutional review board approval and informed consent were obtained for this study. Twenty-seven spine MR scans were performed with metal artifact reduction SEMAC between May 2011 and July 2012 in patients with metallic devices. The MR scans were performed on a 3-T MR system (Achieva; Philips Healthcare, Best, the Netherlands) including SEMAC-corrected T2-weighted axial/sagittal images and two-dimensional fast spin echo (FSE) axial/sagittal images. The SEMAC-corrected images were compared to conventional T2-weighted FSE images. Two musculoskeletal radiologists qualitatively analyzed the images in terms of visualization of the pedicle, vertebral body, dural sac, intervertebral disc, intervertebral neural foramina, screws and metallic artifacts. The paired images were rated using a 5-point scale. P values less than .05 were considered to indicate statistically significant differences. Results: The SEMAC-corrected MR images significantly reduced the metal-related artifacts. The T2-weighted images with SEMAC sequences enabled significantly improved periprosthetic visualizations of the pedicle, vertebral body, dural sac and neural foramina, with the exception of the intervertebral disc (P<.05). In addition, there was significant improvement in prosthesis visualization (P<.05). Conclusion: MR images with SEMAC can reduce metal-related artifacts, providing improved delineation of the prosthesis and periprosthetic region. However, for the evaluation of the intervertebral disc, the SEMAC-corrected MR images showed no significant benefits. ID (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:703 / 706
页数:4
相关论文
共 12 条
[11]   MR IMAGING OF SUSCEPTIBILITY-INDUCED MAGNETIC-FIELD INHOMOGENEITIES [J].
WENDT, RE ;
WILCOTT, MR ;
NITZ, W ;
MURPHY, PH ;
BRYAN, RN .
RADIOLOGY, 1988, 168 (03) :837-841
[12]  
White Lawrence M, 2002, Semin Musculoskelet Radiol, V6, P5, DOI 10.1055/s-2002-23160