Noise sources in imaging static Fourier transform spectrometers

被引:10
作者
Ferrec, Yann [1 ]
Ayari-Matallah, Noura [2 ,3 ]
Chavel, Pierre [2 ]
Goudail, Francois [2 ]
Sauer, Herve [2 ]
Taboury, Jean [2 ]
Fontanella, Jean-Claude [3 ]
Coudrain, Christophe [1 ]
Primot, Jerome [1 ]
机构
[1] Off Natl Etud & Rech Aerosp, F-91123 Palaiseau, France
[2] Univ Paris 11, CNRS, Inst Opt, Lab Charles Fabry, F-91127 Palaiseau, France
[3] Thales Optron SA, F-78990 Elancourt, France
关键词
hyperspectral imaging; Fourier spectroscopy; noise; imaging systems; INTERFEROMETER; PERFORMANCE;
D O I
10.1117/1.OE.51.11.111716
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Imaging static Fourier transform spectrometers are well-adapted instruments for remote sensing. However, the path from the raw images to the spectral images is quite long, thus multiplying the potential noise sources. In this article, we propose to review these perturbation sources. We first recall how detector or photon noise on the interferogram affects the estimated spectrum. Then, we focus on inhomogeneities of the focal plane array. Although these inhomogeneities are deterministic, they generate noise when they are ill-corrected. Finally, we describe defects due to errors that may occur during the image processing step. We also give some avenues to limit the impact of these noises. (C) 2012 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.OE.51.11.111716]
引用
收藏
页数:10
相关论文
共 33 条
  • [1] Ayari-Matallah N., 2011, THESIS U PARIS 11
  • [2] Simulation of the performance of a stationary imaging interferometer for high resolution monitoring of the Earth
    Barducci, A
    Marcoionni, P
    Pippi, I
    Poggesi, M
    [J]. SENSORS, SYSTEMS AND NEXT-GENERATION SATELLITES V, 2001, 4540 : 112 - 121
  • [3] Radiometric and signal-to-noise ratio properties of multiplex dispersive spectrometry
    Barducci, Alessandro
    Guzzi, Donatella
    Lastri, Cinzia
    Nardino, Vanni
    Marcoionni, Paolo
    Pippi, Ivan
    [J]. APPLIED OPTICS, 2010, 49 (28) : 5366 - 5373
  • [4] Relevance of an inverse problem approach to overcome cut-off wavenumbers disparities in infrared stationary Fourier transform spectrometers
    Benoit-Pasanau, Celine
    Gillard, Frederic
    Ferrec, Yann
    Lefebvre, Sidonie
    Rommeluere, Sylvain
    Guerineau, Nicolas
    Primot, Jerome
    [J]. APPLIED OPTICS, 2012, 51 (11) : 1660 - 1670
  • [5] New 3-5 μ wavelength range hyperspectral imager for ground and airborne use based on a single element interferometer
    Cabib, Dario
    Gil, Amir
    Lavi, Moshe
    Buckwald, Robert A.
    Lipson, Stephen G.
    [J]. ELECTRO-OPTICAL AND INFRARED SYSTEMS: TECHNOLOGY AND APPLICATIONS IV, 2007, 6737
  • [6] Chamberlain JohnErnest., 1979, The principles of interferometric spectroscopy
  • [7] Davis S. P., 2001, FOURIER TRANSFORM SP
  • [8] Ferrec Y., 2008, THESIS U PARIS 11
  • [9] Experimental results from an airborne static Fourier transform imaging spectrometer
    Ferrec, Yann
    Taboury, Jean
    Sauer, Herve
    Chavel, Pierre
    Fournet, Pierre
    Coudrain, Christophe
    Deschamps, Joel
    Primot, Jerome
    [J]. APPLIED OPTICS, 2011, 50 (30) : 5894 - 5904
  • [10] Imaging polarization spectrometer based on the Wollaston prisms
    Gao, Zhan
    Mao, Yaya
    Chen, Xiaolei
    Lin, Zeming
    [J]. OPTICAL ENGINEERING, 2011, 50 (04)