Analytical evaluation of a quadruple-mode micro-flow ultrasonic nebulizer for sample introduction in microwave induced plasma spectrometry

被引:7
作者
Matusiewicz, Henryk [1 ]
Slachcinski, Mariusz [1 ]
机构
[1] Poznan Univ Tech, Fac Chem Technol, PL-60965 Poznan, Poland
关键词
Microwave induced plasma-optical emission spectrometry; Inorganic multielemental analysis; Micro-ultrasonic nebulizer; Microliter sample introduction; Certified reference materials; LIQUID MICROSAMPLES; INTRODUCTION SYSTEM; COLD VAPOR; ELEMENTS; INTERFACE; HYDRIDE; ZN; PB; CD; MN;
D O I
10.1016/j.microc.2016.10.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The analytical potential of a coupled continuous-micro-flow ultrasonic nebulizer quadruple-mode micro-capillary system (mu-USN-QCS)-argon-helium microwave induced plasma-optical emission spectrometry (MIP-OES) has been evaluated for the purpose of determination of inorganic elements (Ba, Ca, Cd, Cu, Fe, Mg, Mn, Pb, Sr, Zn). The nebulizer incorporates four solution capillaries with independent liquid feeding and a common gas inlet. Four different spray chambers were evaluated and the geometry of the best performing one was optimized. A univariate approach and the simplex optimization procedure were used to achieve optimized conditions and derive analytical figures of merit. Analytical performance of the ultrasonic nebulization system was characterized by a determination of the limits of detection (LODs) and precision (RSDs) with the mu-USN-QCS-MIP-OES observed at a 40 mu L, min(-1) flow rate. The experimental concentration detection limits for simultaneous determination, calculated as the concentration giving a signal equal to three times of the standard deviation of the blank (LOD, 3 sigma(blank) criterion, peak height) were in the range from 2.8 ng mL(-1) for Cu to 30 ng mL(-1) for Ba. The method offers relatively good precision (RSD ranged from 6% to 8%) for micro-sampling analysis. The methodology was validated through determination of elements in certified reference materials (NRCC DOLT-2, NRC GBW 07302, NIST 2710 and NIST 1643e) and by the aqueous standard calibration technique. The measured of contents of elements in the reference materials were in satisfactory agreement with the certified values. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:345 / 352
页数:8
相关论文
共 27 条
[1]   SAMPLE INTRODUCTION TECHNIQUES FOR ATOMIC SPECTROSCOPY [J].
BROWNER, RF ;
BOORN, AW .
ANALYTICAL CHEMISTRY, 1984, 56 (07) :A875-+
[2]   EFFECT OF ANALYTE AND SOLVENT TRANSPORT ON SIGNAL INTENSITIES IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
BROWNER, RF ;
CANALS, A ;
HERNANDIS, V .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (05) :659-673
[3]  
Canals A., 2015, Encyclopedia of Analytical Chemistry, P1
[4]   Characteristics of nebulizers for microwave-induced plasma atomic emission spectrometry - II. Ultrasonic nebulizers [J].
Jankowski, K ;
Karmasz, D ;
Ramsza, A ;
Reszke, E .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (12) :1813-1823
[5]  
Jankowski KJ, 2011, RSC ANAL SPECTROSC M, P1
[6]   Spectroscopic diagnostics for evaluation of the analytical potential of argon plus helium microwave-induced plasma with solution nebulization [J].
Jankowski, Krzysztof ;
Jackowska, Adrianna .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (09) :1076-1082
[7]  
Jin QH, 2000, LAB ROBOTICS AUTOMAT, V12, P76, DOI 10.1002/(SICI)1098-2728(2000)12:2<76::AID-LRA5>3.0.CO
[8]  
2-R
[9]   Development and investigation of microwave plasma techniques in analytical atomic spectrometry [J].
Jin, QH ;
Duan, YX ;
Olivares, JA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (02) :131-161
[10]   AN EFFICIENT AND INEXPENSIVE ULTRASONIC NEBULIZER FOR ATOMIC SPECTROMETRY [J].
JIN, QH ;
ZHU, C ;
BRUSHWYLER, K ;
HIEFTJE, GM .
APPLIED SPECTROSCOPY, 1990, 44 (02) :183-186