Reproductibility of apparent diffusion coefficients measurements in diffusion-weighted MRI of the abdomen with different b values

被引:44
作者
Bilgili, Mirace Yasemin Karadeniz [1 ]
机构
[1] Kirikkale Univ, Fac Med, Dept Radiol, TR-06590 Cebeci Ankara, Turkey
关键词
Abdomen; ADC; b value; Reproductibility; PARALLEL IMAGING TECHNIQUE; FOCAL HEPATIC-LESIONS; ABDOMINAL ORGANS; ADC MEASUREMENTS; LIVER; REPRODUCIBILITY;
D O I
10.1016/j.ejrad.2011.06.045
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To test the reproducibility of apparent diffusion coefficients (ADC) measurements of the normal liver, kidney and spleen parenchyma with different b values. Materials and methods: Eleven healthy volunteers were imaged twice with use of the same protocol. Each DWI was performed with b-factors of 0, 100 and 500s/mm(2). The ADCs were organized according to session (1 or 2), anatomic location and repetition (twice with two different b value per session). The ADC data were analyzed with repeated-measures analysis of variance to demonstrate the influence of anatomic location, session and different b values. The coefficient of variation was calculated for each subject, b value and anatomic location, then analyzed by using repeated-measures analysis of variance. Results: There were significant differences in mean ADCs among the three anatomic locations and with different b values (P < .05). There were no significant differences in ADCs between imaging sessions 1 or 2 for both b values (P > .05). The CV values range between 7.3% and 14.7%. There were no significant differences in CV values neither between the two b values nor for the various organ locations (P > .05). Conclusion: Using the same technical parameters, patients and the same observer, CV values range between 7.3% and 14.7%. And we recommend to be careful in examination and comparison of the measured ADC values, below these limits, without knowledge technical parameters that has been used, otherwise differences that are merely because of changes in the measurement technique could be interpreted as differences because of progression of disease or therapy. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:2066 / 2068
页数:3
相关论文
共 16 条
[1]   Diffusion-Weighted Magnetic Resonance Imaging as a Cancer Biomarker: Consensus and Recommendations [J].
不详 .
NEOPLASIA, 2009, 11 (02) :102-125
[2]   Short- and Midterm Reproducibility of Apparent Diffusion Coefficient Measurements at 3.0-T Diffusion-weighted Imaging of the Abdomen [J].
Braithwaite, Adam C. ;
Dale, Brian M. ;
Boll, Daniel T. ;
Merkle, Elmar M. .
RADIOLOGY, 2009, 250 (02) :459-465
[3]   Characterization of focal liver lesions by ADC measurements using a respiratory triggered diffusion-weighted single-shot echo-planar MR imaging technique [J].
Bruegel, Melanie ;
Holzapfel, Konstantin ;
Gaa, Jochen ;
Woertler, Klaus ;
Waldt, Simone ;
Kiefer, Berthold ;
Stemmer, Alto ;
Ganter, Carl ;
Rummeny, Ernst J. .
EUROPEAN RADIOLOGY, 2008, 18 (03) :477-485
[4]   MR-Diffusion Weighted Imaging of Healthy Liver Parenchyma: Repeatability and Reproducibility of Apparent Diffusion Coefficient Measurement [J].
Colagrande, Stefano ;
Pasquinelli, Filippo ;
Mazzoni, Lorenzo Nicola ;
Belli, Giacomo ;
Virgili, Gianni .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (04) :912-920
[5]   Field Strength and Diffusion Encoding Technique Affect the Apparent Diffusion Coefficient Measurements in Diffusion-Weighted Imaging of the Abdomen [J].
Dale, Brian M. ;
Braithwaite, Adam C. ;
Boll, Daniel T. ;
Merkle, Elmar M. .
INVESTIGATIVE RADIOLOGY, 2010, 45 (02) :104-108
[6]   Diffusion weighted imaging in the liver [J].
Kele, Petra G. ;
van der Jagt, Eric J. .
WORLD JOURNAL OF GASTROENTEROLOGY, 2010, 16 (13) :1567-1576
[7]  
Kilickesmez Ö, 2008, DIAGN INTERV RADIOL, V14, P83
[8]   Diffusion-weighted MRI in the body: Applications and challenges in oncology [J].
Koh, Dow-Mu ;
Collins, David J. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (06) :1622-1635
[9]   Role of diffusion-weighted magnetic resonance imaging in the differential diagnosis of focal hepatic lesions [J].
Koike, Naoto ;
Cho, Akihiro ;
Nasu, Katsuhiro ;
Seto, Kazuhiko ;
Nagaya, Shigeyuki ;
Ohshima, Yuji ;
Ohkohchi, Nobuhiro .
WORLD JOURNAL OF GASTROENTEROLOGY, 2009, 15 (46) :5805-5812
[10]   Comparison and Reproducibility of ADC Measurements in Breathhold, Respiratory Triggered, and Free-Breathing Diffusion-Weighted MR Imaging of the Liver [J].
Kwee, Thomas C. ;
Takahara, Taro ;
Koh, Dow-Mu ;
Nievelstein, Rutger A. J. ;
Luijten, Peter R. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (05) :1141-1148