Effects of draught on thermal comfort and respiratory immunity

被引:5
作者
Cheng, Xiaoxue [1 ]
Zhou, Ziying [1 ]
Yang, Chunguang [3 ,4 ]
Zheng, Xiaohong [1 ]
Liu, Cong [1 ]
Huang, Wenbo [3 ]
Yang, Zifeng [3 ,4 ,5 ]
Qian, Hua [1 ,2 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Nanjing, Peoples R China
[2] Hubei Engn Ctr Infect Dis Prevent Control & Treatm, Wuhan, Peoples R China
[3] Guangzhou Med Univ, Guangzhou Inst Resp Hlth, Natl Clin Res Ctr Resp Dis, State Key Lab Resp Dis,Affiliated Hosp 1, Guangzhou, Guangdong, Peoples R China
[4] Guangzhou Lab, Guangzhou, Peoples R China
[5] Macau Univ Sci & Technol, Macau Inst Appl Res Med & Hlth, State Key Lab Qual Res Chinese Med, Taipa, Macau, Peoples R China
基金
中国国家自然科学基金;
关键词
Thermal comfort; SIgA; Lysozyme; Respiratory immunity; Buildings; Environment; COMMON COLD; TRACT INFECTIONS; AIR-POLLUTION; ENVIRONMENT; ADAPTATION; INCREASES; SYMPTOMS; HUMIDITY; IGA;
D O I
10.1016/j.buildenv.2022.109537
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Draught has been observed to have an effect on human thermal comfort and induce upper respiratory tract infections (URTI), which indicates that it may reduce immunity against respiratory diseases. This study aims to explore the relationship between thermal comfort and respiratory immunity in an air-conditioned environment. Eleven tests were conducted using supply air temperature of 24 degrees C and supply air velocity of 1 m/s in an environmental chamber. Secretory immunoglobulin A (SIgA) and lysozyme were selected as immune biomarkers, and subjective questionnaires concerning thermal sensation vote and thermal comfort vote (TSV and TCV), draught vote (DV), and air movement acceptability were collected after airflow intervention. The symptoms of URTI were also assessed. The results showed that the lysozyme concentration decreased significantly from 835.01 to 434.16 ng/ml after the tests were conducted (p < 0.01). Furthermore, the lysozyme concentration after the tests showed a significant positive correlation with TSV (Rs = 0.527, p < 0.05). The colder the subjects felt, the greater the decrease in the lysozyme change rate. There was no correlation between SIgA and TSV after the tests (p > 0.05). This study revealed that staying in comfortable conditions contributes to a high level of respiratory immunity.
引用
收藏
页数:8
相关论文
共 48 条
  • [1] Ashrae A., 2017, ASHRAE Standard, 55-201 7-Thermal Environmental Conditions for Human Occupancy, 55-201 7
  • [2] Barrett B, 2005, J CLIN EPIDEMIOL, V58, P609, DOI 10.1016/j.jclinepi.2004.11.019
  • [3] Influence of relative air humidity and movement on human thermal perception in classrooms in a hot and humid climate
    Buonocore, Carolina
    De Vecchi, Renata
    Scalco, Veridiana
    Lamberts, Roberto
    [J]. BUILDING AND ENVIRONMENT, 2018, 146 : 98 - 106
  • [4] Salivary immunity and lower respiratory tract infections in non-elite marathon runners
    Canto, Elisabet
    Roca, Emma
    Perea, Lidia
    Rodrigo-Troyano, Ana
    Suarez-Cuartin, Guillermo
    Giner, Jordi
    Feliu, Anna
    Manuel Soria, Jose
    Nescolarde, Lexa
    Vidal, Silvia
    Sibila, Oriol
    [J]. PLOS ONE, 2018, 13 (11):
  • [5] Investigation of outdoor thermal sensation and comfort evaluation methods in severe cold area
    Chen, Xin
    Gao, Lixin
    Xue, Puning
    Du, Jing
    Liu, Jing
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 749 (749)
  • [6] Experimental study of thermal comfort in a field environment chamber with stratum ventilation system in winter
    Cheng, Fanghui
    Wu, Yuxin
    Gao, Shasha
    Liao, Chunhui
    Cheng, Yong
    [J]. BUILDING AND ENVIRONMENT, 2022, 207
  • [7] Effect of cooling on electrical field stimulation and norepinephrine-induced contraction in isolated hypertrophic human nasal mucosa
    Chu, Yueng-Hsiang
    Wu, Chin-Chen
    Wang, Hsing-Won
    [J]. AMERICAN JOURNAL OF RHINOLOGY, 2006, 20 (05): : 471 - 475
  • [8] Role of secretory IgA in infection and maintenance of homeostasis
    Corthesy, Blaise
    [J]. AUTOIMMUNITY REVIEWS, 2013, 12 (06) : 661 - 665
  • [9] The impact of cold on the respiratory tract and its consequences to respiratory health
    D'Amato, Maria
    Molino, Antonio
    Calabrese, Giovanna
    Cecchi, Lorenzo
    Annesi-Maesano, Isabella
    D'Amato, Gennaro
    [J]. CLINICAL AND TRANSLATIONAL ALLERGY, 2018, 8
  • [10] pH in exhaled breath condensate and nasal lavage as a biomarker of air pollution-related inflammation in street traffic-controllers and office-workers
    de Lima, Thamires Marques
    Kazama, Cristiane Mayumi
    Koczulla, Andreas Rembert
    Hiemstra, Pieter S.
    Macchione, Mariangela
    Godoy Fernandes, Ana Luisa
    Santos, Ubiratan de Paula
    Bueno-Garcia, Maria Lucia
    Zanetta, Dirce Maria
    Saldiva de Andre, Carmen Diva
    Nascimento Saldiva, Paulo Hilario
    Nakagawa, Naomi Kondo
    [J]. CLINICS, 2013, 68 (12) : 1488 - 1494