Composite hydrogels containing polypyrrole as support membranes for amperometric enzyme biosensors

被引:14
作者
Guiseppi-Elie, A
Brahim, S
Narinesingh, D
机构
[1] Virginia Commonwealth Univ, Dept Chem Engn, Richmond, VA 23284 USA
[2] Virginia Commonwealth Univ, Ctr Bioelect Biosensors & Biochips C3B, Richmond, VA 23284 USA
[3] Univ W Indies, Dept Chem, St Augustine, Trinidad Tobago
来源
JOURNAL OF MACROMOLECULAR SCIENCE-PURE AND APPLIED CHEMISTRY | 2001年 / 38卷 / 12期
关键词
hydrogel; methacrylates; conducting polymer; polypyrrole; amperometric biosensor; glucose oxidase; glucose; cholesterol oxidase; cholesterol; galactose oxidase; galactose; ascorbic acid; uric acid; cysteine; acetaminophen;
D O I
10.1081/MA-100108406
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Conducting polymers and redox hydrogels are shown to be attractive materials for biocompatible electrodes in amperometric biosensors. We have combined electrically conducting polypyrrole (PPy) with crosslinked poly(2-hydroxyethylmethacrylate) (p-HEMA) to produce a novel composite hydrogel membrane. The high water content of these materials provides a biocompatible environment for the long-term immobilization of enzymes and a more favorable medium for the rapid movement of charge neutralizing ions. Electrode-supported composite films were prepared by UV polymerization of the hydrogel component (containing dissolved enzyme) followed immediately by electrochemical polymerization (+0.7V vs. Ag/AgCl) of the pyrrole component within the interstitial spaces of the pre-formed hydrogel network. Typical monomer compositions consisted of HEMA:TEGDA:pyrrole in an 85:10:05 vol%. (TEGDA = tetraethyleneglycol diacrylate). An optimized glucose biosensor displayed a wide linear response range of 5.0 x 10(-5) to 2.0 x 10(-2) M, a detection limit (3S(y/x)/sensitivity) of 25 muM and a response time of 35-40 seconds. The analytical recovery of glucose in serum samples ranged from 98 to 102% with mean coefficients of variation of 4.4% (within-day analyses) and 5.1% (day-to-day analyses). The optimized cholesterol and galactose biosensors also displayed wide linear response ranges (5.0 x 10(-4) - 1.5 x 10(-2) M and 1.0 x 10(-4) - 1.0 x 10(-2) M, respectively) towards their respective substrates. All three biosensors retained > 70% of initial activity after 9 months when stored desiccated in the absence of buffer. An attractive feature with all the biosensors was their ability to effectively screen the endogenous interferents ascorbic acid, uric acid, L-cysteine and acetaminophen. This characteristic, coupled with the high biocompatibility of the polymeric hydrogel composites make these materials potential candidates for in-vivo biosensors.
引用
收藏
页码:1575 / 1591
页数:17
相关论文
共 24 条
[1]   Fabrication of ultra-thin polypyrrole-glucose oxidase film from supporting electrolyte-free monomer solution for potentiometric biosensing of glucose [J].
Adeloju, SB ;
Moline, AN .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (03) :133-139
[2]  
BARTLETT PN, 1993, J ELECTROANAL CHEM, V362, P1
[3]   Improvement of the analytical characteristics of an enzyme electrode for free and total cholesterol via laponite clay additives [J].
Besombes, JL ;
Cosnier, S ;
Labbe, P ;
Reverdy, G .
ANALYTICA CHIMICA ACTA, 1995, 317 (1-3) :275-280
[4]  
BRAHIM S, IN PRESS BIOSENS BIO
[5]  
BRAHIM S, IN PRESS ANAL CHIM A
[6]  
BRAHIM S, 2000, P AM CHEM SOC DIV PO, V83, P514
[7]   ENZYME CATALYSIS AT HYDROGEL-MODIFIED ELECTRODES WITH REDOX POLYMER MEDIATOR [J].
CALVO, EJ ;
DANILOWICZ, C ;
DIAZ, L .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1993, 89 (02) :377-384
[8]   Amperometric determination of cholesterol in serum with use of a renewable surface peroxidase electrode [J].
Charpentier, L ;
ElMurr, N .
ANALYTICA CHIMICA ACTA, 1995, 318 (01) :89-93
[9]   ELECTROCHEMICAL RESPONSE OF AN ENZYME-LOADED POLYANILINE FILM [J].
COOPER, JC ;
HALL, EAH .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (07) :473-485
[10]   Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review [J].
Cosnier, S .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (05) :443-456