Electrical impedance tomography system based on active electrodes

被引:66
作者
Gaggero, Pascal Olivier [1 ,2 ]
Adler, Andy [3 ]
Brunner, Josef [4 ]
Seitz, Peter [1 ,5 ]
机构
[1] Ctr Suisse Elect & Microtech SA CSEM, Landquart, Switzerland
[2] Inst Human Centered Engn, BFH, Biel, Switzerland
[3] Carleton Univ, Ottawa, ON K1S 5B6, Canada
[4] Swisstom AG, Landquart, Switzerland
[5] EPFL, Inst Microengn, Neuchatel, Switzerland
关键词
electrical impedance tomography; hardware; EIT; active electrode; electrode belt; ACQUISITION-SYSTEM;
D O I
10.1088/0967-3334/33/5/831
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Electrical impedance tomography (EIT) can image the distribution of ventilated lung tissue, and is thus a promising technology to help monitor patient breathing to help selection of mechanical ventilation parameters. Two key difficulties in EIT instrumentation make such monitoring difficult: (1) EIT data quality depends on good electrode contact and is sensitive to changes in contact quality, and (2) EIT electrodes are difficult and time consuming to place on patients. This paper presents the design and initial tests of an active electrode-based system to address these difficulties. Our active electrode EIT system incorporates an active electrode belt, a central voltage-driven current source, central analog to digital converters and digital to analog converters, a central FPGA-based demodulator and controller. The electrode belt is designed incorporating 32 active electrodes, each of which contains the electronic amplifiers, switches and associated logic. Tests show stable device performance with a convenient ease of use and good imaging ability in volunteer tests.
引用
收藏
页码:831 / 847
页数:17
相关论文
共 21 条
[1]   Uses and abuses of EIDORS: an extensible software base for EIT [J].
Adler, A ;
Lionheart, WRB .
PHYSIOLOGICAL MEASUREMENT, 2006, 27 (05) :S25-S42
[2]   Effect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome [J].
Amato, MBP ;
Barbas, CSV ;
Medeiros, DM ;
Magaldi, RB ;
Schettino, GDP ;
Lorenzi, G ;
Kairalla, RA ;
Deheinzelin, D ;
Munoz, C ;
Oliveira, R ;
Takagaki, TY ;
Carvalho, CRR .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 338 (06) :347-354
[3]  
Drager, 2011, DRAG PULMOVISTA 500
[4]  
Gaggero P.O., 2011, Ph.D. thesis
[5]  
GUARDO R, 1994, PROCEEDINGS OF THE 16TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY - ENGINEERING ADVANCES: NEW OPPORTUNITIES FOR BIOMEDICAL ENGINEERS, PTS 1&2, P545, DOI 10.1109/IEMBS.1994.411911
[6]  
Hahn G., 2002, Proc. Conf. 2nd European Medical and Biological Engineering (Vienna, P110
[7]  
Holder D. S., 2004, Electrical Impedance Tomography: Methods, History and Applications (Series in Medical Physics and Biomedical Engineering)
[8]   A High Output Impedance CMOS Current Driver for Bioimpedance Measurements [J].
Hong, Hongwei ;
Demosthenous, Andreas ;
Triantis, Iasonas F. ;
Langlois, Peter ;
Bayford, Richard .
2010 BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2010, :230-233
[9]  
Hong S, 2007, IFMBE PROC, V17, P348
[10]  
IEC, 2005, 2005606011 IEC, P60601