共 21 条
Reutilization of the Prolift™ system for the simultaneous correction of prolapse and incontinence in patients with pelvic organ prolapse and stress urinary incontinence
被引:4
作者:
Ignjatovic, Ivan
[1
]
Basic, Dragoslav
[1
]
Stosic, Dragan
[2
]
Potic, Milan
[1
]
Mitic, Predrag
[1
]
Milic, Vladimir
[1
]
机构:
[1] Clin Ctr Nis, Urol Clin, Nish, Serbia
[2] Clin Ctr Nis, Clin Gynecol & Obstet, Nish, Serbia
关键词:
Pelvic organ prolapse;
Prolift (TM);
Sling;
D O I:
10.1016/j.ejogrb.2008.03.016
中图分类号:
R71 [妇产科学];
学科分类号:
100211 ;
摘要:
Objective: The reutilization of the Prolift (TM) system with the simultaneous creation of a midurethral sling from the same set was described. Study design: The technique was applied in 23 patients with pelvic organ prolapse (POP) and clinically evident or occult stress urinary incontinence (SUI). Results: Correction of POP was achieved in 21 out of 23 (91.3%) patients, and complete continence after the surgery in 20 out of 23 (86.9%). There was a significant improvement in voiding symptoms without deterioration of voiding function. Morbidity of the surgery was not different from that with Prolift (TM) alone. Conclusion: Modification of the method with creation of a suburethral sling from the same set is more economically viable without compromising either pelvic organ support or continence. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:79 / 82
页数:4