Assessment of a novel biomechanical fracture model for distal radius fractures

被引:14
作者
Baumbach, Sebastian Felix [1 ]
Dall'Ara, Enrico [2 ]
Weninger, Patrick [3 ]
Antoni, Anna [3 ]
Traxler, Hannes [4 ]
Doerr, Martin [5 ,6 ]
Zysset, Philippe K. [7 ]
机构
[1] Univ Munich, Dept Surg Expt Surg & Regenerat Med, Munich, Germany
[2] Vienna Univ Technol, Inst Lightweight Design & Struct Biomech, A-1040 Vienna, Austria
[3] Lorenz Boehler Trauma Hosp, Ludwig Boltzmann Inst Expt & Clin Traumatol, Vienna, Austria
[4] Med Univ Vienna, Dept Systemat Anat, Ctr Anat & Cell Biol, Vienna, Austria
[5] Munich Canc Registry, Munich, Germany
[6] Univ Munich, IBE Clin Grosshadern, Munich, Germany
[7] Univ Bern, Inst Surg Technol & Biomech, Bern, Switzerland
关键词
Biomechanical fracture model; Distal radius fracture; Fresh-frozen; Plate osteosynthesis; FINITE-ELEMENT MODEL; VOLAR LOCKING PLATE; COLLES FRACTURE; EXTRAARTICULAR FRACTURES; FIXATION; PREDICTION; STABILITY; LOAD;
D O I
10.1186/1471-2474-13-252
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Distal radius fractures (DRF) are one of the most common fractures and often need surgical treatment, which has been validated through biomechanical tests. Currently a number of different fracture models are used, none of which resemble the in vivo fracture location. The aim of the study was to develop a new standardized fracture model for DRF (AO-23.A3) and compare its biomechanical behavior to the current gold standard. Methods: Variable angle locking volar plates (ADAPTIVE, Medartis) were mounted on 10 pairs of fresh-frozen radii. The osteotomy location was alternated within each pair (New: 10 mm wedge 8 mm / 12 mm proximal to the dorsal / volar apex of the articular surface; Gold standard: 10 mm wedge 20 mm proximal to the articular surface). Each specimen was tested in cyclic axial compression (increasing load by 100 N per cycle) until failure or -3 mm displacement. Parameters assessed were stiffness, displacement and dissipated work calculated for each cycle and ultimate load. Significance was tested using a linear mixed model and Wald test as well as t-tests. Results: 7 female and 3 male pairs of radii aged 74 +/- 9 years were tested. In most cases (7/10), the two groups showed similar mechanical behavior at low loads with increasing differences at increasing loads. Overall the novel fracture model showed a significant different biomechanical behavior than the gold standard model (p < 0,001). The average final loads resisted were significantly lower in the novel model (860 N +/- 232 N vs. 1250 N +/- 341 N; p = 0.001). Conclusion: The novel biomechanical fracture model for DRF more closely mimics the in vivo fracture site and shows a significantly different biomechanical behavior with increasing loads when compared to the current gold standard.
引用
收藏
页数:7
相关论文
共 28 条
[1]  
Augat P, 1996, J BONE MINER RES, V11, P1356
[2]   Distal radius fractures: Mechanisms of injury and strength prediction by bone mineral assessment [J].
Augat, P ;
Iida, H ;
Jiang, YB ;
Diao, E ;
Genant, HK .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1998, 16 (05) :629-635
[3]   Where Is the Distal Fracture Line Location of Dorsally Displaced Distal Radius Fractures? [J].
Baumbach, Sebastian Felix ;
Schmidt, Reinhard ;
Varga, Peter ;
Heinz, Thomas ;
Vecsei, Vilmos ;
Zysset, Philippe K. .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2011, 29 (04) :489-494
[4]   Volar versus dorsal locking plates with and without radial styloid locking plates for the fixation of dorsally comminuted distal radius fractures: A biomechanical study in cadavers [J].
Blythe, Murray ;
Stoffel, Karl ;
Jarrett, Paul ;
Kuster, Markus .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (10) :1587-1593
[5]   Can We Trust Ex Vivo Mechanical Testing of Fresh-Frozen Cadaveric Specimens? The Effect of Postfreezing Delays [J].
Cartner, Jacob L. ;
Hartsell, Zane M. ;
Ricci, William M. ;
Tornetta, Paul, III .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (08) :459-461
[6]  
Cooper Ellis O, 2007, Am J Orthop (Belle Mead NJ), V36, pE46
[7]  
Dunning CE, 1999, J HAND SURG-AM, V24A, P992
[8]  
EKENSTAM F, 1985, SCAND J PLAST RECONS, V19, P27
[9]   Quantitative computed tomography (QCT) of the forearm using general purpose spiral whole-body CT scanners: Accuracy, precision and comparison with dual-energy X-ray absorptiometry (DXA) [J].
Engelke, Klaus ;
Libanati, Cesar ;
Liu, Yu ;
Wang, Huei ;
Austin, Matt ;
Fuerst, Tom ;
Stampa, Bernd ;
Timm, Wolfram ;
Genant, Harry K. .
BONE, 2009, 45 (01) :110-118
[10]   Biomechanical Comparison of Locking versus Nonlocking Volar and Dorsal T-Plates for Fixation of Dorsally Comminuted Distal Radius Fractures [J].
Gondusky, Joseph S. ;
Carney, Joseph ;
Erpenbach, Jonathan ;
Robertson, Claire ;
Mahar, Andrew ;
Oka, Richard ;
Thompson, Michael ;
Mazurek, Michael .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (01) :44-50