Precise Heart Rate Measurement Using Non-contact Doppler Radar Assisted by Machine-Learning-Based Sleep Posture Estimation

被引:0
|
作者
Higashi, Kotaro [1 ]
Sun, Guanghao [1 ]
Ishibashi, Koichiro [1 ]
机构
[1] Univ Electrocommun UEC, Grad Sch Informat & Engn, 1-5-1 Chofugaoka, Chofu, Tokyo 1828585, Japan
来源
2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC) | 2019年
关键词
Doppler radar; body movement; sleep monitoring; vital sign; heart rate; machine learning;
D O I
10.1109/embc.2019.8857830
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Non-contact and continuous heart rate measurement using Doppler radar is important for various healthcare applications. In this paper, we propose a precise heart rate measurement method assisted by machine learning based sleep posture estimation. Machine learning is used for processing time-domain signal of the Doppler radar. Doppler radar has attracted much attention due to its non-contact to the subject feature. Moreover, it will not encroach into the privacy of the subject compared to image sensors. The method proposed in this paper automatically removes the data from the raw signal while the patient is moving or is not staying on the bed. This method based on machine learning uses simple features to reduce the computational cost thereby enabling real-time application. The sleeping posture was detected with an accuracy of 88.5%, and the error ratios of heart rate estimation were reduced by 15.2% in a sleep laboratory testing on 6 subjects.
引用
收藏
页码:788 / 791
页数:4
相关论文
共 31 条
  • [1] Development of a heart rate detection algorithm using a non-contact doppler radar via signal elimination
    Oh, Sang Hoon
    Lee, SeungBong
    Kim, Sung Min
    Jeong, Jae Hoon
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2021, 64
  • [2] Non-Contact Breathing Rate Estimation Using Machine Learning with an Optimized Architecture
    Brieva, Jorge
    Ponce, Hiram
    Moya-Albor, Ernesto
    MATHEMATICS, 2023, 11 (03)
  • [3] Doppler Radar-Based Non-Contact Health Monitoring for Obstructive Sleep Apnea Diagnosis: A Comprehensive Review
    Vinh Phuc Tran
    Al-Jumaily, Adel Ali
    Islam, Syed Mohammed Shamsul
    BIG DATA AND COGNITIVE COMPUTING, 2019, 3 (01) : 1 - 21
  • [4] Medical Radar Signal Dataset for Non-Contact Respiration and Heart Rate Measurement
    Edanami, Keisuke
    Sun, Guanghao
    DATA IN BRIEF, 2022, 40
  • [5] Non-contact Heart Rate Measurement based on Camera Image
    Kitajima, Toshihiro
    Choi, SangOn
    Murakami, Edwardo Arata Y.
    JOURNAL OF INFORMATION ASSURANCE AND SECURITY, 2015, 10 (03): : 120 - 129
  • [6] Non-Contact Heart Rate Monitoring Based on Millimeter Wave Radar
    Ling, Zongquan
    Zhou, Weinan
    Ren, Yuhao
    Wang, Jiping
    Guo, Liquan
    IEEE ACCESS, 2022, 10 : 74033 - 74044
  • [7] Non-contact Blood Pressure Estimation Using a 300 GHz Continuous Wave Radar and Machine Learning Models
    Jung, Marie
    Canis, Michael
    Stanko, Stephan
    2021 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (IEEE MEMEA 2021), 2021,
  • [8] Non-contact Beat-to-beat Blood Pressure Measurement Using Continuous Wave Doppler Radar
    Zhao, Heng
    Gu, Xu
    Hong, Hong
    Li, Yusheng
    Zhu, Xiaohua
    Li, Changzhi
    2018 IEEE/MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM - IMS, 2018, : 1413 - 1415
  • [9] Non-Contact Measurement of Human Respiration and Heartbeat Using W-band Doppler Radar Sensor
    Kim, Heesoo
    Jeong, Jinho
    SENSORS, 2020, 20 (18)
  • [10] A Direct Phase-Tracking Doppler Radar Using Wavelet Independent Component Analysis for Non-Contact Respiratory and Heart Rate Monitoring
    Mercuri, Marco
    Liu, Yao-Hong
    Lorato, Ilde
    Torfs, Tom
    Wieringa, Fokko
    Bourdoux, Andre
    Van Hoof, Chris
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2018, 12 (03) : 632 - 643