High temperature in-situ XRD of plasma sprayed HA coatings

被引:39
作者
Kweh, SWK
Khor, KA
Cheang, P
机构
[1] Nanyang Technol Univ, Sch Mech & Prod Engn, Singapore 639798, Singapore
[2] Nanyang Technol Univ, Sch Mat Engn, Singapore 639798, Singapore
关键词
hydroxyapatite; plasma spray; X-ray diffraction; high temperature pbase transformations;
D O I
10.1016/S0142-9612(01)00116-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The control of phase transformations in plasma sprayed hydroxyapatite (HA) coatings are critical to the clinical performance of the material. This paper reports the use of high temperature X-ray diffraction (HT-XRD) to study, in-situ, the phase transformations occurring in plasma sprayed HA coatings. The coatings were prepared using different spray power levels (net plasma power of 12 and 15 kW and different starting powder size ranges (20-45, 45-75 mum). The temperature range employed was room temperature ( similar to 26 degreesC) to 900 degreesC in normal atmosphere and pressure. High temperature differential scanning calorimetry (DSC) was also employed to investigate and determine the precise onset temperature of phase transformations during the recrystallization process. Results showed that actual onset of thermal degradation in the coating into other metastable phases like TTCP, beta -TCP and CaO occurred at 638 degreesC. The aforementioned phase transitions were independent of the selected spraying parameters. The degree of melting and thermal dissociation of HA actually determines the amount of calcium phosphate phases that are formed. A high power level of 15 kW produced a greater degree of melting, resulting in more CaO, TTCP and beta -TCP being formed as a result. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:381 / 387
页数:7
相关论文
共 18 条
[1]  
BONFIELD W, 1987, BIOMATERIALS CLIN AP, P13
[2]  
Chen JY, 1997, J BIOMED MATER RES, V34, P15, DOI 10.1002/(SICI)1097-4636(199701)34:1<15::AID-JBM3>3.0.CO
[3]  
2-Q
[4]  
de Groot K., 1987, INTERCERAM, V4, P38
[5]   Direct morphological comparison of vacuum plasma sprayed and detonation gun sprayed hydroxyapatite coatings for orthopaedic applications [J].
Gledhill, HC ;
Turner, IG ;
Doyle, C .
BIOMATERIALS, 1999, 20 (04) :315-322
[6]  
Gross KA, 1998, J BIOMED MATER RES, V39, P580, DOI 10.1002/(SICI)1097-4636(19980315)39:4<580::AID-JBM12>3.3.CO
[7]  
2-Y
[8]  
Gross KA, 1998, J AM CERAM SOC, V81, P106, DOI 10.1111/j.1151-2916.1998.tb02301.x
[9]   Oxyapatite in hydroxyapatite coatings [J].
Gross, KA ;
Berndt, CC ;
Stephens, P ;
Dinnebier, R .
JOURNAL OF MATERIALS SCIENCE, 1998, 33 (15) :3985-3991
[10]  
Gross KA, 1998, THERMAL SPRAY, VOLS 1 AND 2, P1133