Comparative Evaluation Between DC and AC Breakdown Characteristic of Dielectric Insulating Materials in Liquid Nitrogen

被引:21
作者
Seong, J. K. [1 ]
Seo, I. J. [1 ]
Hwang, J. S. [1 ]
Lee, B. W. [1 ]
机构
[1] Hanyang Univ, Dept Elect Elect Control & Instrumentat Engn, Ansan 426791, South Korea
关键词
DC insulator; dielectric breakdown; dielectric materials; superconducting material;
D O I
10.1109/TASC.2011.2178222
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Due to the existence of AC loss in superconducting materials when an alternating voltage is applied, high cryogenic costs are inevitable to operate superconducting devices in AC networks. Therefore applications of superconducting devices in DC electric power networks could be regarded as the optimum choice for superconducting devices, because superconductors show exactly zero resistance to a DC source. Recently, DC superconducting devices such as DC cables have received noticeable attention as DC power transmission lines. In order to develop DC superconducting devices, the DC insulation characteristics in cryogenic liquids should be clarified. However, up to now, limited research has been reported in this field. In this paper, to clarify the different breakdown characteristics of DC and AC applications, various kinds of cryogenic dielectric sheets including Kraft, Kapton (polyimide) and Nomex (polyamide) papers have been prepared. Furthermore, a penetrating breakdown test for three kinds of sheets and turn-to-turn breakdown tests have been performed in liquid nitrogen (LN2). Consequently, it was found that the prepared sheets have shown 1.7-2.7 times higher dielectric strength than those of AC. Moreover, the Nomex and Kraft sheets have shown a remarkable increase in their dielectric strength in liquid nitrogen compared to air. However, the dielectric strength of the Kapton sheet did not show a remarkable increase in liquid nitrogen. From the turn-to-turn breakdown test, it was proved that the dielectric strength has been linearly increased according to the wrapping number of the sheets and that the DC breakdown voltage was 1.1-2.5 times higher than AC.
引用
收藏
页数:4
相关论文
共 11 条
  • [1] POSSIBLE HIGH-TC SUPERCONDUCTIVITY IN THE BA-LA-CU-O SYSTEM
    BEDNORZ, JG
    MULLER, KA
    [J]. ZEITSCHRIFT FUR PHYSIK B-CONDENSED MATTER, 1986, 64 (02): : 189 - 193
  • [2] Feasibility of electric power transmission by DC superconducting cables
    Chowdhuri, P
    Pallem, C
    Demko, JA
    Gouge, MJ
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2005, 15 (04) : 3917 - 3926
  • [3] Chowdhuri P., 1979, 7th IEEE/PES Transmission and Distribution Conference and Exposition, P140, DOI 10.1109/TDC.1979.712652
  • [4] Haq S. U., 2006, IEEE T DIELECTRICS E, V13
  • [5] Johnson B. K., 1994, IEEE T APPL SUPERCON, V4
  • [6] Kitani I., 1989, JAPANESE J APPL PHYS, V28
  • [7] Investigation of partial discharge phenomena in HTS transformer adopting different type of sensors
    Koo, J. Y.
    Lee, S. H.
    Lee, Y. J.
    Lee, B. W.
    [J]. PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2010, 470 (20): : 1684 - 1690
  • [8] Kreuger F. H., 1991, IND HIGH VOLTAGE, V3, P134
  • [9] Lee S. H., 2010, IEEE T APPL SUPERCON, V20
  • [10] Riechert U., 1998, IEEE INT C COND BREA