Direct electrochemistry of sarcosine oxidase on graphene, chitosan and silver nanoparticles modified glassy carbon electrode and its biosensing for hydrogen peroxide

被引:60
|
作者
Zhou, Yunlei [1 ]
Yin, Huanshun [1 ]
Meng, Xiaomeng [1 ]
Xu, Zhenning [1 ]
Fu, Yanrong [1 ]
Ai, Shiyun [1 ]
机构
[1] Shandong Agr Univ, Coll Chem & Mat Sci, Tai An 271018, Shandong, Peoples R China
关键词
Sarcosine oxidase; Direct electrochemistry; Graphene; Silver nanoparticles; Hydrogen peroxide; HORSERADISH-PEROXIDASE; IONIC LIQUID; GLUCOSE-OXIDASE; COLLOIDAL GOLD; HEME-PROTEINS; CYTOCHROME-C; ELECTROCATALYSIS; FILM; HEMOGLOBIN; MYOGLOBIN;
D O I
10.1016/j.electacta.2012.04.014
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The direct electrochemistry of sacrosine oxidase (SOX) immobilized on graphene, chitosan and silver nanoparticles (AgNPs) modified glassy carbon electrode was realized. SOX exhibits a pair of well-defined reversible redox peaks in 0.1 M pH 7.0 phosphate buffer solution (PBS) with the oxidation peak potential of-0.446V and the reduction peak potential of -0.496 V. The immobilized SOX retains its bioactivity, and exhibits a surface confined, reversible two-proton and two-electron transfer reaction. It also has good stability, and a fast heterogeneous electron transfer rate with the rate constant (k(s)) of 1.8 s(-1). The surface coverage of SOX is 1.18 x 10(-7) mol/cm(7). This biosensor shows excellent sensitivity towards H2O2 in 0.1 M PBS (pH 7.0) with a wide linear range from 1.0 to 177 mu M. The detection limit is 1.0 mu M. The apparent Michaelis-Menten constant for immobilized SOX is calculated to be 0.18 mM. The excellent performance of the biosensor is attributed to large specific surface area and high conductivity of graphene and AgNPs, and good biocompatibility of chitosan, which improve the enzyme absorption and promote direct electron transfer between SOX and the electrode surface. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:294 / 301
页数:8
相关论文
共 50 条
  • [31] Hydrogen peroxide biosensor based on hemoglobin immobilized at graphene, flower-like zinc oxide, and gold nanoparticles nanocomposite modified glassy carbon electrode
    Xie, Lingling
    Xu, Yuandong
    Cao, Xiaoyu
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2013, 107 : 245 - 250
  • [32] Monitoring of hydrogen peroxide using a glassy carbon electrode modified with hemoglobin and a polypyrrole-based nanocomposite
    Baghayeri, Mehdi
    Zare, Ehsan Nazarzadeh
    Lakouraj, Moslem Mansour
    MICROCHIMICA ACTA, 2015, 182 (3-4) : 771 - 779
  • [33] Direct Electrochemistry of Glucose Oxidase at Reduced Graphene Oxide and -Cyclodextrin Composite Modified Electrode and Application for Glucose Biosensing
    Palanisamy, Selvakumar
    Devasenathipathy, Rajkumar
    Chen, Shen-Ming
    Ali, M. Ajmal
    Karuppiah, Chelladurai
    Balakumar, V.
    Prakash, P.
    Elshikh, Mohamed S.
    Al-Hemaid, Fahad M. A.
    ELECTROANALYSIS, 2015, 27 (10) : 2412 - 2420
  • [34] Direct electrochemistry of myoglobin at reduced graphene oxide-multiwalled carbon nanotubes-platinum nanoparticles nanocomposite and biosensing towards hydrogen peroxide and nitrite
    Mani, Veerappan
    Dinesh, Bose
    Chen, Shen-Ming
    Saraswathi, Ramiah
    BIOSENSORS & BIOELECTRONICS, 2014, 53 : 420 - 427
  • [35] Electroanalysis of Hydrogen Peroxide at Boron Doped Diamond Electrode Modified by Silver Nanoparticles and Haemoglobin
    Jiang, Luyun
    Hu, Jingping
    Foord, John S.
    ELECTROCHIMICA ACTA, 2015, 176 : 488 - 496
  • [36] Hydrogen peroxide biosensor based on the direct electrochemistry of myoglobin immobilized on silver nanoparticles doped carbon nanotubes film
    Liu, Chuan-Yin
    Hu, Ji-Ming
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (07) : 2149 - 2154
  • [37] A Novel Hydrogen Peroxide Sensor Based on Silver Nanoparticles Electrodeposited on PFS-DNA Networks Modified Glassy Carbon Electrode
    He, Z. F.
    Song, Y. H.
    Wang, L.
    Wan, L. L.
    Zhu, H. Z.
    Gao, S.
    ASIAN JOURNAL OF CHEMISTRY, 2012, 24 (09) : 3837 - 3841
  • [38] Direct electrochemistry and electrocatalysis of hemoglobin on chitosan-room temperature ionic liquid-TiO2-graphene nanocomposite film modified electrode
    Sun, Jun-Yong
    Huang, Ke-Jing
    Zhao, Su-Fang
    Fan, Yang
    Wu, Zhi-Wei
    BIOELECTROCHEMISTRY, 2011, 82 (02) : 125 - 130
  • [39] Amperometric hydrogen peroxide biosensor based on a glassy carbon electrode modified with polythionine and gold nanoparticles
    Wang, Qingxia
    Zhang, Haili
    Wu, Yiwei
    Yu, Aimin
    MICROCHIMICA ACTA, 2012, 176 (3-4) : 279 - 285
  • [40] Direct electrochemistry of glucose oxidase immobilized on chitosan-gold nanoparticle composite film on glassy carbon electrodes and its biosensing application
    Sheng Qing-Lin
    Shen Yu
    Zhang Hong-Fang
    Zheng Jian-Bin
    CHINESE JOURNAL OF CHEMISTRY, 2008, 26 (07) : 1244 - 1250