Direct electrochemistry of sarcosine oxidase on graphene, chitosan and silver nanoparticles modified glassy carbon electrode and its biosensing for hydrogen peroxide

被引:60
|
作者
Zhou, Yunlei [1 ]
Yin, Huanshun [1 ]
Meng, Xiaomeng [1 ]
Xu, Zhenning [1 ]
Fu, Yanrong [1 ]
Ai, Shiyun [1 ]
机构
[1] Shandong Agr Univ, Coll Chem & Mat Sci, Tai An 271018, Shandong, Peoples R China
关键词
Sarcosine oxidase; Direct electrochemistry; Graphene; Silver nanoparticles; Hydrogen peroxide; HORSERADISH-PEROXIDASE; IONIC LIQUID; GLUCOSE-OXIDASE; COLLOIDAL GOLD; HEME-PROTEINS; CYTOCHROME-C; ELECTROCATALYSIS; FILM; HEMOGLOBIN; MYOGLOBIN;
D O I
10.1016/j.electacta.2012.04.014
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The direct electrochemistry of sacrosine oxidase (SOX) immobilized on graphene, chitosan and silver nanoparticles (AgNPs) modified glassy carbon electrode was realized. SOX exhibits a pair of well-defined reversible redox peaks in 0.1 M pH 7.0 phosphate buffer solution (PBS) with the oxidation peak potential of-0.446V and the reduction peak potential of -0.496 V. The immobilized SOX retains its bioactivity, and exhibits a surface confined, reversible two-proton and two-electron transfer reaction. It also has good stability, and a fast heterogeneous electron transfer rate with the rate constant (k(s)) of 1.8 s(-1). The surface coverage of SOX is 1.18 x 10(-7) mol/cm(7). This biosensor shows excellent sensitivity towards H2O2 in 0.1 M PBS (pH 7.0) with a wide linear range from 1.0 to 177 mu M. The detection limit is 1.0 mu M. The apparent Michaelis-Menten constant for immobilized SOX is calculated to be 0.18 mM. The excellent performance of the biosensor is attributed to large specific surface area and high conductivity of graphene and AgNPs, and good biocompatibility of chitosan, which improve the enzyme absorption and promote direct electron transfer between SOX and the electrode surface. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:294 / 301
页数:8
相关论文
共 50 条
  • [21] Direct electrochemistry and electrocatalysis of glucose oxidase immobilized on reduced graphene oxide and silver nanoparticles nanocomposite modified electrode
    Palanisamy, Selvakumar
    Karuppiah, Chelladurai
    Chen, Shen-Ming
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2014, 114 : 164 - 169
  • [22] Direct Electrochemistry of Glucose Oxidase on a Graphene-Graphene Oxide Nanocomposite-Modified Electrode for a Glucose Biosensor
    Wang, Bo
    Wang, Xiaoli
    He, Zhifang
    Zhao, Xiufeng
    Wang, Linyu
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (08): : 7495 - 7506
  • [23] Direct electrochemistry of hemoglobin/peptide-carbon nanotube modified electrode for hydrogen peroxide biosensing
    Sheikholeslam, Mohammadali
    Nanda, Piyush
    Sanati, Alireza
    Pritzker, Mark
    Chen, P.
    MATERIALS LETTERS, 2023, 335
  • [24] A Hydrogen Peroxide Biosensor Based on Direct Electrochemistry of Hemoglobin in Palladium Nanoparticles/Graphene–Chitosan Nanocomposite Film
    Aili Sun
    Qinglin Sheng
    Jianbin Zheng
    Applied Biochemistry and Biotechnology, 2012, 166 : 764 - 773
  • [25] Direct electrochemistry of chemically modified catalase immobilized on an oxidatively activated glassy carbon electrode
    Hashemnia, Sedigheh
    Ghourchian, Hedayatollah
    Moosavi-Movahedi, Ali Aakbar
    Faridnouri, Hassan
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2009, 39 (01) : 7 - 14
  • [26] A novel hydrogen peroxide biosensor based on horseradish peroxidase immobilized on gold nanoparticles-silk fibroin modified glassy carbon electrode and direct electrochemistry of horseradish peroxidase
    Yin, Huanshun
    Ai, Shiyun
    Shi, Weijie
    Zhu, Lusheng
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 137 (02) : 747 - 753
  • [27] Novel Hydrogen Peroxide Sensor Based on Chitosan-Ag Nanoparticles Electrodeposited on Glassy Carbon Electrode
    Zhang, Mei
    Song, Yonghai
    Wang, Li
    Wan, Lingli
    Xiao, Xianping
    Ye, Shuhong
    ASIAN JOURNAL OF CHEMISTRY, 2012, 24 (01) : 18 - 22
  • [28] Hydrogen Peroxide Biosensor based on Carbon Paste Modified Electrode with Hemoglobin and Copper(II) Oxide Nanoparticles
    Abbasi, Amin
    Shamsazar, Ali
    Shamsazar, Fatemeh
    Asadi, Asadollah
    Shamsaldini, Soghra
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (04): : 3986 - 3996
  • [29] Amperometric Hydrogen Peroxide Biosensor Based on Immobilization of Hemoglobin on a Glassy Carbon Electrode Modified with Fe3O4/Chitosan Core-Shell Microspheres
    Tan, Xue-Cai
    Zhang, Jin-Lei
    Tan, Sheng-Wei
    Zhao, Dan-Dan
    Huang, Zen-Wei
    Mi, Yan
    Huang, Zai-Yin
    SENSORS, 2009, 9 (08) : 6185 - 6199
  • [30] Glucose sensing by a glassy carbon electrode modified with glucose oxidase/chitosan/graphene oxide nanofibers
    Mehdizadeh, Bentolhoda
    Maleknia, Laleh
    Amirabadi, Amir
    Shabani, Mohammad
    DIAMOND AND RELATED MATERIALS, 2020, 109