Five-Year Results of 5-Fluorouracil Augmented Needling Revision of Failing Blebs

被引:10
作者
Dalvi, Rajesh [1 ]
Orzech, Neil [1 ]
Kranemann, Christoph [1 ]
Birt, Catherine M. [1 ]
机构
[1] Univ Toronto, Dept Ophthalmol & Vis Sci, Toronto, ON, Canada
关键词
GLAUCOMA FILTERING SURGERY; FOLLOW-UP; INTRAOCULAR-PRESSURE; TRABECULECTOMY BLEBS;
D O I
10.3928/15428877-20111129-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND AND OBJECTIVE: To report the 5-year intraocular pressure (IOP) outcomes of patients requiring a 5-fluorouracil (5-FU) needling revision compared to a matched sample. PATIENTS AND METHODS: Forty eyes receiving 5-FU bleb needling revision were matched to 40 patients not needled. IOP was recorded preoperatively and annually to 5 years. The main outcome measure was surgical success: IOP control without medications or surgery. RESULTS: Thirty-two patients with 5-FU needling revision (80.0%) required anti-glaucoma medication postoperatively versus 28 control patients (70%) (P > .05). Thirty-two patients with 5-FU needling revision were complete or qualified successes compared to 36 control patients (P = .34). Eight patients with 5-FU needling revision (20%) had a reoperation versus 4 control patients (10%) (P > .05). CONCLUSION: 5-FU needling revision can produce long-term IOP control levels similar to those who did not require the procedure. No statistically significant differences between the two groups was seen in either the use of medications or further surgery.
引用
收藏
页码:32 / 38
页数:7
相关论文
共 32 条
[1]   The treatment of encapsulated trabeculectomy blebs in an out-patient setting using a needling technique and subconjunctival 5-fluorouracil injection [J].
Allen, LE ;
Manuchehri, K ;
Corridan, PG .
EYE, 1998, 12 (1) :119-123
[2]  
Alward WLM, 1996, AM J OPHTHALMOL, V121, P349
[3]  
Borisuth N S, 1999, Curr Opin Ophthalmol, V10, P112, DOI 10.1097/00055735-199904000-00006
[4]   Needle revision of failing and failed trabeculectomy blebs with adjunctive 5-fluorouracil survival analysis [J].
Broadway, DC ;
Bloom, PA ;
Bunce, C ;
Thiagarajan, M ;
Khaw, PT .
OPHTHALMOLOGY, 2004, 111 (04) :665-673
[5]   Needling revision of glaucoma drainage device filtering blebs [J].
Chen, PP ;
Palmberg, PF .
OPHTHALMOLOGY, 1997, 104 (06) :1004-1010
[6]   Canadian perspectives in glaucoma management: setting target intraocular pressure range [J].
Damji, KF ;
Behki, R ;
Wang, L .
CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2003, 38 (03) :189-197
[7]  
DRANCE SM, 1973, CAN J OPHTHALMOL, V8, P413
[8]   The national survey of trabeculectomy. II. Variations in operative technique and outcome [J].
Edmunds, B ;
Thompson, JR ;
Salmon, JF ;
Wormald, RP .
EYE, 2001, 15 (4) :441-448
[9]   NEEDLE REVISION WITH AND WITHOUT 5-FLUOROURACIL FOR THE TREATMENT OF FAILED FILTERING BLEBS [J].
EWING, RH ;
STAMPER, RL .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1990, 110 (03) :254-259
[10]   Needle Revision of Filtering Blebs [J].
Feldman, Robert M. ;
Tabet, Rania R. .
JOURNAL OF GLAUCOMA, 2008, 17 (07) :594-600