Peat as a natural solid-phase for copper preconcentration and determination in a multicommuted flow system coupled to flame atomic absorption spectrometry

被引:325
作者
Gonzales, A. P. S. [1 ]
Firmino, M. A. [2 ]
Nomura, C. S. [1 ]
Rocha, F. R. P. [3 ]
Oliveira, P. V. [3 ]
Gaubeur, I. [1 ]
机构
[1] Univ Fed ABC, Ctr Ciencias Nat & Humanas, BR-09210170 Santo Andre, Brazil
[2] Univ Presbiteriana Mackenzie, Dept Mat Engn, Escola Engn, BR-01302970 Sao Paulo, Brazil
[3] Univ Sao Paulo, Inst Quim, Dept Quim Fundamental, BR-05508000 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
Peat; Preconcentration; Flow analysis; Multicommutation; Copper; ONLINE PRECONCENTRATION; METAL-IONS; COMPETITIVE ADSORPTION; EQUILIBRIUM ISOTHERM; POLYURETHANE FOAM; GRAPE BAGASSE; TRACE-METALS; CADMIUM; LEAD; EXTRACTION;
D O I
10.1016/j.aca.2009.01.047
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The physical and chemical characteristics of peat were assessed through measurement of pH, percentage of organic matter, cationic exchange capacity (CEC), elemental analysis, infrared spectroscopy and quantitative analysis of metals by ICP OES. Despite the material showed to be very acid in view of the percentage of organic matter, its CEC was significant, showing potential for retention of metal ions. This characteristic was exploited by coupling a peat mini-column to a flow system based on the multicommutation approach for the in-line copper concentration prior to flame atomic absorption spectrometric determination. Cu(II) ions were adsorbed at pH 4.5 and eluted with 0.50 mol L-1 HNO3. The influence of chemical and hydrodynamic parameters, such as sample pH, buffer concentration, eluent type and concentration, sample flow-rate and preconcentration time were investigated. Under the optimized conditions, a linear response was observed between 16 and 100 mu g L-1, with a detection limit estimated as 3 mu g L-1 at the 99.7% confidence level and an enrichment factor of 16. The relative standard deviation was estimated as 3.3% (n = 20). The mini-column was used for at least 100 sampling cycles without significant variation in the analytical response. Recoveries from copper spiked to lake water or groundwater as well as concentrates used in hemodialysis were in the 97.3-111 % range. The results obtained for copper determination in these samples agreed with those achieved by graphite furnace atomic absorption spectrometry (GFAAS) at the 95% confidence level. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:198 / 204
页数:7
相关论文
共 44 条
[1]  
[Anonymous], 1987, ANALYST, V112, P199
[2]   On-line preconcentration and determination of copper, lead and chromium(VI) using unloaded polyurethane foam packed column by flame atomic absorption spectrometry in natural waters and biological samples [J].
Anthemidis, AN ;
Zachariadis, GA ;
Stratis, JA .
TALANTA, 2002, 58 (05) :831-840
[3]   Evaluation of polychlorotrifluoroethylene as sorbent material for on-line solid phase extraction systems: Determination of copper and lead by flame atomic absorption spectrometry in water samples [J].
Anthemidis, Aristidis N. ;
Ioannou, Kallirroy-Ioanna G. .
ANALYTICA CHIMICA ACTA, 2006, 575 (01) :126-132
[4]  
AVILATERRA LHS, 1999, SPECTROSC LETT, V32, P257
[5]   Removal of Pb(II) from aqueous solution using carbon derived from agricultural wastes [J].
Ayyappan, R ;
Sophia, AC ;
Swaminathan, K ;
Sandhya, S .
PROCESS BIOCHEMISTRY, 2005, 40 (3-4) :1293-1299
[6]   Electrothermal atomic absorption spectrometric determination of lead, cadmium, copper and zinc in high-salt content samples after simultaneous separation on polyethylene powder impregnated with 1-(2-pyridylazo)-2-naphthol: application to the analysis of hemodialysis fluids [J].
Bohrer, D ;
do Nascimento, PC ;
Guterres, M ;
Trevisan, M ;
Seibert, E .
ANALYST, 1999, 124 (09) :1345-1350
[7]   Atomic spectrometry update. Environmental analysis [J].
Butler, Owen T. ;
Cook, Jennifer M. ;
Harrington, Chris F. ;
Hill, Steve J. ;
Rieuwerts, John ;
Miles, Douglas L. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (02) :249-286
[8]   Solid phase extraction of trace elements [J].
Camel, V .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (07) :1177-1233
[9]   Synthesis and application of a functionalized resin for flow injection/F AAS copper determination in waters [J].
Cassella, RJ ;
Magalhaes, OIB ;
Couto, MT ;
Lima, ELS ;
Neves, MAFS ;
Coutinho, FMB .
TALANTA, 2005, 67 (01) :121-128
[10]   Characterization of solid and aqueous phases of a peat bog profile using molecular fluorescence spectroscopy, ESR and FT-IR, and comparison with physical properties [J].
Cocozza, C ;
D'Orazio, V ;
Miano, TM ;
Shotyk, W .
ORGANIC GEOCHEMISTRY, 2003, 34 (01) :49-60