Reducing the sensitivity of IMPT treatment plans to setup errors and range uncertainties via probabilistic treatment planning

被引:257
作者
Unkelbach, Jan [1 ,2 ]
Bortfeld, Thomas [1 ,2 ]
Martin, Benjamin C. [3 ]
Soukup, Martin [4 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
[3] Boston Univ, Dept Elect & Comp Engn, Boston, MA 02115 USA
[4] Univ Hosp Radiat Oncol, Sect Biomed Phys, Tubingen, Germany
关键词
IMPT optimization; range uncertainty; setup error; MODULATED PROTON THERAPY; DOSE UNCERTAINTIES; IMRT OPTIMIZATION; HETEROGENEITIES;
D O I
10.1118/1.3021139
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Treatment plans optimized for intensity modulated proton therapy (IMPT) may be very sensitive to setup errors and range uncertainties. If these errors are not accounted for during treatment planning, the dose distribution realized in the patient may by strongly degraded compared to the planned dose distribution. The authors implemented the probabilistic approach to incorporate uncertainties directly into the optimization of an intensity modulated treatment plan. Following this approach, the dose distribution depends on a set of random variables which parameterize the uncertainty, as does the objective function used to optimize the treatment plan. The authors optimize the expected value of the objective function. They investigate IMPT treatment planning regarding range uncertainties and setup errors. They demonstrate that incorporating these uncertainties into the optimization yields qualitatively different treatment plans compared to conventional plans which do not account for uncertainty. The sensitivity of an IMPT plan depends on the dose contributions of individual beam directions. Roughly speaking, steep dose gradients in beam direction make treatment plans sensitive to range errors. Steep lateral dose gradients make plans sensitive to setup errors. More robust treatment plans are obtained by redistributing dose among different beam directions. This can be achieved by the probabilistic approach. In contrast, the safety margin approach as widely applied in photon therapy fails in IMPT and is neither suitable for handling range variations nor setup errors. (C) 2009 American Association of Physicists in Medicine. [DOI: 10.1118/1.3021139]
引用
收藏
页码:149 / 163
页数:15
相关论文
共 27 条
[1]  
Baldi P., 1998, Bioinformatics: The machine learning approach
[2]   A fluence-convolution method to calculate radiation therapy dose distributions that incorporate random set-up error [J].
Beckham, WA ;
Keall, PJ ;
Siebers, JV .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (19) :3465-3473
[3]   Effects of motion on the total dose distribution [J].
Bortfeld, T ;
Jiang, SB ;
Rietzel, E .
SEMINARS IN RADIATION ONCOLOGY, 2004, 14 (01) :41-51
[4]   Treatment planning for conformal proton radiation therapy [J].
Bussière, MR ;
Adams, JA .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2003, 2 (05) :389-399
[5]   Four-dimensional proton treatment planning for lung tumors [J].
Engelsman, M ;
Rietzel, E ;
Kooy, HM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (05) :1589-1595
[6]   Realistic estimation of proton range uncertainties and dosimetric implications [J].
Flampouri, S. ;
Slopsema, R. ;
Yeung, D. ;
Malyapa, R. ;
Keole, S. ;
Vargas, C. ;
Li, Z. .
MEDICAL PHYSICS, 2007, 34 (06) :2643-2643
[7]   The influence of metal artefacts on the range of ion beams [J].
Jaekel, Oliver ;
Reiss, Petra .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (03) :635-644
[8]   4D proton treatment planning strategy for mobile lung tumors [J].
Kang, Yixiu ;
Zhang, Xiaodong ;
Chang, Joe Y. ;
Wang, He ;
Wei, Xiong ;
Liao, Zhongxing ;
Komaki, Ritsuko ;
Cox, James D. ;
Balter, Peter A. ;
Liu, Helen ;
Zhu, X. Ronald ;
Mohan, Radhe ;
Dong, Lei .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (03) :906-914
[9]   Intensity modulation methods for proton radiotherapy [J].
Lomax, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (01) :185-205
[10]   Intensity modulated proton therapy and its sensitivity to treatment uncertainties 2: the potential effects of inter-fraction and inter-field motions [J].
Lomax, A. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (04) :1043-1056