Experimentally validated model and power optimization of a magnetoelectric wireless power transfer system in free-free configuration

被引:26
作者
Truong, Binh Duc [1 ]
Roundy, Shad [1 ]
机构
[1] Univ Utah, Dept Mech Engn, 1495 E 100 S,1550 MEK, Salt Lake City, UT 84112 USA
基金
美国国家科学基金会;
关键词
wireless power transfer; magneto-electric effect; longitudinal vibration; equivalent circuit model; power optimization; MAGNETOSTRICTIVE/PIEZOELECTRIC LAMINATE COMPOSITE; VOLTAGE COEFFICIENTS; TRANSMISSION; FREQUENCY; LINK;
D O I
10.1088/1361-665X/ab90a2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This article presents a thorough analysis and an equivalent circuit model of a wireless power transfer system utilizing magnetoelectric (ME) effects. Based on two-port theory, explicit analytical solutions of, (i) the ME coefficient alpha(ME) defined by the derivative of the generated electric field with respect to the applied magnetic field), and (ii) the power transferred to a load resistance, are derived and rigorously validated by experiments. The compact closed-forms of the optimal load and its corresponding maximum output power are developed. In our particular experimental system, a power of similar to 10 mW is attained at an applied magnetic flux density of 318.9 mu T with a laminated composite made by two Galfenol and one PZT layers. While alpha(ME) is widely used in the literature as a standard criterion to evaluate the performance of a ME transducer, we reveal that larger alpha(ME) does not always ensure higher optimum power delivered to the load. Instead, we quantify the essential influences of each magnetostrictive and piezoelectric phases on the maximum obtainable power. We show that the transduction factor between the magnetic and mechanical domains is often more critical for power optimization than the mechanical-electrical transduction factor as it determines and limits the maximum power available for transfer to a resistive load.
引用
收藏
页数:15
相关论文
共 56 条
[31]   A 10.5 cm Ultrasound Link for Deep Implanted Medical Devices [J].
Mazzilli, Francesco ;
Lafon, Cyril ;
Dehollain, Catherine .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2014, 8 (05) :738-750
[32]  
McRobbie D, 2011, HEALTH PHYS, V100, P442, DOI 10.1097/HP.0b013e31820c2101
[33]   Resonant Inductive Link for Remote Powering of Pacemakers [J].
Monti, Giuseppina ;
Arcuti, Paola ;
Tarricone, Luciano .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2015, 63 (11) :3814-3822
[34]   Applications of Wireless Power Transfer in Medicine: State-of-the-Art Reviews [J].
Moore, Julian ;
Castellanos, Sharon ;
Xu, Sheng ;
Wood, Bradford ;
Ren, Hongliang ;
Tse, Zion Tsz Ho .
ANNALS OF BIOMEDICAL ENGINEERING, 2019, 47 (01) :22-38
[35]   Acoustically actuated ultra-compact NEMS magnetoelectric antennas [J].
Nan, Tianxiang ;
Lin, Hwaider ;
Gao, Yuan ;
Matyushov, Alexei ;
Yu, Guoliang ;
Chen, Huaihao ;
Sun, Neville ;
Wei, Shengjun ;
Wang, Zhiguang ;
Li, Menghui ;
Wang, Xinjun ;
Belkessam, Amine ;
Guo, Rongdi ;
Chen, Brian ;
Zhou, James ;
Qian, Zhenyun ;
Hui, Yu ;
Rinaldi, Matteo ;
McConney, Michael E. ;
Howe, Brandon M. ;
Hu, Zhongqiang ;
Jones, John G. ;
Brown, Gail J. ;
Sun, Nian Xiang .
NATURE COMMUNICATIONS, 2017, 8
[36]   Wireless energy transfer based on strain-mediated composite multiferroics [J].
Newacheck, Scott ;
Youssef, George .
SMART MATERIALS AND STRUCTURES, 2020, 29 (01)
[37]  
Nocedal J, 2006, SPRINGER SER OPER RE, P1, DOI 10.1007/978-0-387-40065-5
[38]   Improved wireless, transcutaneous power transmission for in vivo applications [J].
O'Handley, Robert C. ;
Huang, Jiankang K. ;
Bono, David Currier ;
Simon, Jesse .
IEEE SENSORS JOURNAL, 2008, 8 (1-2) :57-62
[39]   Multifunctional magnetoelectric materials for device applications [J].
Ortega, N. ;
Kumar, Ashok ;
Scott, J. F. ;
Katiyar, Ram S. .
JOURNAL OF PHYSICS-CONDENSED MATTER, 2015, 27 (50)
[40]   Theoretical model for the magnetoelectric effect in magnetostrictive/piezoelectric composites [J].
Osaretin, Idahosa A. ;
Rojas, Roberto G. .
PHYSICAL REVIEW B, 2010, 82 (17)