Suppression of lightning-induced overvoltages by distribution line surge arresters

被引:0
|
作者
Fujiwara, N [1 ]
Yoneyama, T [1 ]
Hamada, Y [1 ]
Yokota, T [1 ]
Asakawa, A [1 ]
Shimomura, T [1 ]
Yamaoka, K [1 ]
Ishibe, S [1 ]
机构
[1] CENT RES INST ELECT POWER IND,ELECT & PHYS DEPT,LIGHTNING DISCHARGE GRP,KOMAE LAB,KOMAE,TOKYO 201,JAPAN
关键词
distribution line; direct lightning stroke; overhead ground wire; arrester; experiment; analysis;
D O I
10.1002/eej.4391160604
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The primary aim of surge arresters in power distribution lines is to protect lines and equipment from the voltage induced by nearby lightning strokes. To further improve power systems, methods to protect distribution lines against direct lightning strokes are still needed. An effective measure against direct lightning strokes is to increase the number of arresters. However, if the surge current is too large, some surge arresters absorb energy in excess of their capability and may break; this leads to a line fault. To evaluate the protective effect of the surge arresters against direct lightning strokes to overhead ground wire, the authors measured both the voltage across the surge arresters and the energy absorbed by them using a full-scale model line and a 12 MV impulse generator. The results were compared with simulation results by EMTP. There have been no previous studies making a comparison of this kind.
引用
收藏
页码:32 / 42
页数:11
相关论文
共 50 条
  • [41] Adopting line surge arresters to suppress switching overvoltages in 750 kV EHV transmission lines
    State Key Laboratory of Control and Simulation of Power Systems and Generation Equipment, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
    不详
    Qinghua Daxue Xuebao, 2008, 10 (1545-1548):
  • [42] Calculation Method and Influencing Factors of Lightning-induced Voltage on Overhead Distribution Line
    Li, Weiguo
    Xie, Tao
    Zhang, Wen
    Zhang, Zhanlong
    Mei, Daojun
    2017 IEEE 3RD INFORMATION TECHNOLOGY AND MECHATRONICS ENGINEERING CONFERENCE (ITOEC), 2017, : 420 - 425
  • [43] SWITCHING SURGE OPERATING DUTY OF LIGHTNING ARRESTERS
    SARBACH, E
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1968, PA87 (06): : 1521 - &
  • [44] SURGE ARRESTERS FOR LIMITING OVERVOLTAGES IN HIGH-VOLTAGE SYSTEMS
    MAYER, A
    BROWN BOVERI REVIEW, 1983, 70 (1-2): : 48 - 52
  • [45] OPERATING DUTY OF DISTRIBUTION SURGE ARRESTERS DUE TO INDIRECT LIGHTNING STRIKES.
    Stringfellow, M.F.
    Transactions of the South African Institute of Electrical Engineers, 1981, 72 (pt 5): : 102 - 122
  • [46] SWITCHING SURGE INSULATION COORDINATION - LIGHTNING ARRESTERS
    CARRARA, G
    DELLERA, L
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1968, PA87 (01): : 154 - &
  • [47] Experiments of Lightning Induced Overvoltages on a Real-size Overhead Power Distribution Line
    Yokoyama, Shigeru
    Sekioka, Shozo
    2016 33RD INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2016,
  • [48] Spacer-cable lightning-induced overvoltages computed using measured ground resistances
    Jiang, Grace Ge
    Boggs, Steven
    Tarpey, James W.
    Wamer, Ronald H.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2007, 43 (01) : 202 - 207
  • [49] CALCULATING LIGHTNING-INDUCED OVERVOLTAGES IN POWER-LINES - A COMPARISON OF 2 COUPLING MODELS
    COORAY, V
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1994, 36 (03) : 179 - 182
  • [50] Lightning-induced overvoltage protection for microinverters using surge protective devices
    Mosamane, Simisi
    Gomes, Chandima
    2022 36TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP 2022), 2022, : 138 - 143