Suppression of lightning-induced overvoltages by distribution line surge arresters

被引:0
|
作者
Fujiwara, N [1 ]
Yoneyama, T [1 ]
Hamada, Y [1 ]
Yokota, T [1 ]
Asakawa, A [1 ]
Shimomura, T [1 ]
Yamaoka, K [1 ]
Ishibe, S [1 ]
机构
[1] CENT RES INST ELECT POWER IND,ELECT & PHYS DEPT,LIGHTNING DISCHARGE GRP,KOMAE LAB,KOMAE,TOKYO 201,JAPAN
关键词
distribution line; direct lightning stroke; overhead ground wire; arrester; experiment; analysis;
D O I
10.1002/eej.4391160604
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The primary aim of surge arresters in power distribution lines is to protect lines and equipment from the voltage induced by nearby lightning strokes. To further improve power systems, methods to protect distribution lines against direct lightning strokes are still needed. An effective measure against direct lightning strokes is to increase the number of arresters. However, if the surge current is too large, some surge arresters absorb energy in excess of their capability and may break; this leads to a line fault. To evaluate the protective effect of the surge arresters against direct lightning strokes to overhead ground wire, the authors measured both the voltage across the surge arresters and the energy absorbed by them using a full-scale model line and a 12 MV impulse generator. The results were compared with simulation results by EMTP. There have been no previous studies making a comparison of this kind.
引用
收藏
页码:32 / 42
页数:11
相关论文
共 50 条
  • [31] Role of an overhead ground wire in the generation of lightning-induced voltage over lossy ground
    Hongo, Y
    Michishita, K
    Ishii, M
    ELECTRICAL ENGINEERING IN JAPAN, 1997, 121 (04) : 18 - 27
  • [32] A study on observation results of lightning phenomena on distribution lines based on a lightning-surge analysis model for direct lightning strokes
    High Voltage and Insulation Group, R and D Center, TEPCO, 4-1, Egasaki-cho, Tsurumi-ku, Yokohama 230-8510, Japan
    不详
    IEEJ Trans. Power Energy, 2006, 12 (1295-1303+15): : 1295 - 1303+15
  • [33] EFFECTIVE LIGHTNING PROTECTION SCHEMES FOR DISTRIBUTION LINE
    MASAKI, T
    HIGUCHI, K
    YOKOI, Y
    ELECTRICAL ENGINEERING IN JAPAN, 1995, 115 (04) : 27 - 41
  • [34] Voltage induced on a test distribution line by negative winter lightning strokes to a tall structure
    Michishita, K
    Ishii, M
    Asakawa, A
    Yokoyama, S
    Kami, K
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2003, 45 (01) : 135 - 140
  • [35] Earth Current and GPR Distributions Due to Lightning and Effect of a Distribution Line
    Natsui, Masashi
    Ametani, Akihiro
    Mahseredjian, Jean
    Motoyama, Hideki
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2020, 62 (05) : 2119 - 2127
  • [36] On-line monitoring of lightning induced voltage waveform on 10 kV distribution lines
    Wang J.-G.
    Wang S.-P.
    Cai L.
    Kong Z.
    Fan Y.-D.
    Cai, Li, 1600, Editorial Department of Electric Machines and Control (25): : 1 - 7
  • [37] Return-Stroke Model Segmentation and its Application to Lightning-Induced Surges Calculation
    Sekioka, Shozo
    Matsubara, Ichiro
    Yokoyama, Shigeru
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2011, 53 (01) : 122 - 130
  • [38] An efficient technique for the evaluation of lightning-induced voltage in a cylindrical vessel containing charged oil
    Buccella, C
    Orlandi, A
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2003, 39 (02) : 368 - 373
  • [39] A Model of Pole-Mounted Distribution Transformer for Lightning Failure Analysis -A Model Capable of Calculating Lightning Overvoltages in Transformer Windings-
    Kanatani K.
    Matsuura S.
    Fujita H.
    Michishita K.
    IEEJ Transactions on Power and Energy, 2023, 143 (02) : 165 - 175
  • [40] An improved thermal damage evaluation method for lightning-induced failure analysis of overhead ground wire
    Guo, Deming
    Liu, Gang
    Wang, Peifeng
    Peng, Xiangyang
    Wang, Rui
    Wu, Haonan
    Chen, Yulin
    ENGINEERING FAILURE ANALYSIS, 2024, 159