Analysis of ten abused drugs in urine by large volume sample stacking-sweeping capillary electrophoresis with an experimental design strategy

被引:30
|
作者
Ho, Yu-Hsiang [1 ]
Wang, Chun-Chi [1 ]
Hsiao, Yu-Tzu [2 ]
Ko, Wei-Kung [3 ]
Wu, Shou-Mei [1 ]
机构
[1] Kaohsiung Med Univ, Coll Pharm, Sch Pharm, Kaohsiung 807, Taiwan
[2] Kaohsiung Med Univ, Grad Inst Clin Pharm, Coll Pharm, Kaohsiung 807, Taiwan
[3] Jing Ho Mental Hosp, Kaohsiung, Taiwan
关键词
Abused drugs; Stacking capillary electrophoresis; Experimental design; Urine; MICELLAR ELECTROKINETIC CHROMATOGRAPHY; PERFORMANCE LIQUID-CHROMATOGRAPHY; SOLID-PHASE EXTRACTION; MASS-SPECTROMETRY; GAS-CHROMATOGRAPHY; BENZODIAZEPINES; METABOLITES; MORPHINE; QUANTIFICATION; OPTIMIZATION;
D O I
10.1016/j.chroma.2013.04.057
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A statistical tool equipped with Plackett-Burman design (PBD) and central composite design (CCD) was used for fast stacking analysis of ten frequently consumed drugs, namely codeine, morphine, methamphetamine, ketamine, alprazolam, clonazepam, diazepam, flunitrazepam, nitrazepam and oxazepam, by capillary electrophoresis (CE). This statistical design is expected to help quick analysis with few procedures, avoiding tedious work required because of the large number of variables or parameters. A large volume sample stacking (LVSS)-sweeping CE is developed for concentrating and analyzing the 10 abused drugs. First, phosphate buffer (50 mM, pH 2.3) containing methanol was filled into a capillary and then the extracted urine sample was loaded (1 psi, 200 s) to enhance sensitivity. The sweeping and separating steps were completed simultaneously by phosphate buffer (50 mM, pH 2.3) containing methanol and sodium dodecyl sulfate, within 15 min. Better resolution was obtained by the experimental design than the "one factor at a time" (OFAT) approach. During method validation, calibration plots were linear (r > 0.998), over a range of 25-1500 ng/mL for the six benzodiazepines, methamphetamine and ketamine, and 50-3000 ng/mL for codeine and morphine. The RSD of precision and absolute RE of accuracy in intra-day and inter-day assays were below 14.54% and 16.61%, respectively. The minimum limits for detection (SIN = 3) of analytes were in the range of 7.5-30 ng/mL. This stacking method increased sensitivity more than 200-fold and can be applied for detection of the presence of methamphetamine in an abuser's urine (3600 ng/mL), which was confirmed by GC-MS. The method is considered feasible for fast screening of abused drugs in urine. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:136 / 141
页数:6
相关论文
共 40 条
  • [21] Field-amplified sample stacking capillary zone electrophoresis applied to the analysis of opiate drugs in hair
    Manetto, G
    Tagliaro, F
    Crivellente, F
    Pascali, VL
    Marigo, M
    ELECTROPHORESIS, 2000, 21 (14) : 2891 - 2898
  • [22] Improving sensitivity by large-volume sample stacking using the electroosmotic flow pump to analyze some nonsteroidal anti-inflammatory drugs by capillary electrophoresis in water samples
    Macià, A
    Borrull, F
    Aguilar, C
    Calull, M
    ELECTROPHORESIS, 2003, 24 (16) : 2779 - 2787
  • [23] On-line sample preconcentration by sweeping and poly(ethylene oxide)-mediated stacking for simultaneous analysis of nine pairs of amino acid enantiomers in capillary electrophoresis
    Lin, En-Ping
    Lin, Kai-Cheng
    Chang, Chia-Wei
    Hsieh, Ming-Mu
    TALANTA, 2013, 114 : 297 - 303
  • [24] Application of capillary zone electrophoresis with large-volume sample stacking to the sensitive determination of sulfonamides in meat and ground water
    Soto-Chinchilla, Jorge J.
    Garcia-Campana, Ana M.
    Gamiz-Gracia, Laura
    Cruces-Blanco, Carmen
    ELECTROPHORESIS, 2006, 27 (20) : 4060 - 4068
  • [25] Multivariate optimization of large-volume sample stacking with polarity switching by capillary electrophoresis for determination of gold nanoparticle size
    Chuang, Ya-Tien
    Liou, Jing-Ru
    Chao, Yu-Ying
    Lin, Yi-Hui
    Wu, Tsung-Yan
    Chen, Yen-Ling
    MICROCHEMICAL JOURNAL, 2022, 178
  • [26] Off-line hyphenation of molecularly imprinted magnetic nanoparticle-based extraction with large volume sample stacking capillary electrophoresis for high-sensitivity detection of trace chloro-phenols
    Qi, Shengda
    Zhang, Huige
    Zhu, Qian
    Chen, Hongli
    Dong, Yalei
    Zhou, Lei
    Ren, Cuiling
    Chen, Xingguo
    ANALYTICAL METHODS, 2014, 6 (04) : 1219 - 1226
  • [27] Field amplified sample stacking and in-capillary derivatization for forensic analysis of morphine and morphine-6-glucuronide in human urine by capillary electrophoresis
    Zarad, Walaa
    Shawky, Ahmed
    Ali, Ahmed
    Aboulella, Yasmine
    Kamal, Maha
    Masujima, Tsutomu
    Emara, Samy
    El-Gendy, Heba
    TALANTA OPEN, 2021, 3
  • [28] Large Volume Sample Stacking (LVSS) in Capillary Electrophoresis (CE) with Response Surface Methodology (RSM) for the Determination of Phenolics in Food Samples
    Memon, Almas F.
    Palabiyik, Ismail M.
    Solangi, Amber R.
    Memon, Saima Q.
    Mallah, Arfana B.
    ANALYTICAL LETTERS, 2019, 52 (18) : 2853 - 2867
  • [29] Sensitive Residue Analysis of Quinolones and Sulfonamides in Aquatic Product by Capillary Zone Electrophoresis Using Large-Volume Sample Stacking with Polarity Switching Combined with Accelerated Solvent Extraction
    Wang, Ning
    Su, Ming
    Liang, Shuxuan
    Sun, Hanwen