Status and performance of the CDF Run 2 silicon detectors

被引:0
作者
Nielsen, J [1 ]
机构
[1] Lawrence Berkeley Lab, Div Phys, Berkeley, CA 94720 USA
关键词
silicon microstrip detectors; operation; CDF;
D O I
10.1016/j.nima.2005.11.230
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In 2001, an upgraded silicon detector system was installed in the CDF II experiment on the Tevatron at Fermilab. The complete system consists of three silicon micro-strip detectors:SVX II with five layers for precision tracking, Layer 00 with one beampipe-mounted layer for vertexing, and two Intermediate Silicon Layers located between SVX II and the main CDF II tracking chamber. Currently all detectors in the system are operating at or near design levels. The performance of the combined silicon system is excellent in the context of CDF tracking algorithms, and the first useful physics results from the innermost Layer 00 detector have been recently documented. operational and monitoring efforts have also been strengthened to maintain silicon efficiency through the end of Run 2 at the Tevatron. Published by Elsevier B.V.
引用
收藏
页码:18 / 20
页数:3
相关论文
共 5 条
  • [1] The CDF Silicon Vertex Trigger
    Ashmanskas, B
    Barchiesi, A
    Bardi, A
    Bari, M
    Baumgart, M
    Belforte, S
    Berryhill, J
    Bogdan, M
    Carosi, R
    Cerri, A
    Chlachidze, G
    Culbertson, R
    Dell'Orso, M
    Donati, S
    Fiori, I
    Frisch, H
    Galeotti, S
    Giannetti, P
    Glagolev, V
    Leger, A
    Liu, Y
    Maruyama, T
    Meschi, E
    Moneta, L
    Morsani, F
    Nakaya, T
    Punzi, G
    Rescigno, M
    Ristori, L
    Sanders, H
    Sarkar, S
    Semenov, A
    Shochet, M
    Speer, T
    Spinella, F
    Vataga, H
    Wu, X
    Yang, UK
    Zanello, L
    Zanetti, AM
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 518 (1-2) : 532 - 536
  • [2] Wire-bond failures induced by resonant vibrations in the CDF silicon detector
    Bolla, G
    Atac, M
    Pavlicek, V
    Nahn, S
    Garcia-Sciveres, M
    Mumford, R
    Nguyen, T
    Forrester, S
    Hill, C
    Olszewski, J
    Rahaman, A
    Goldstein, J
    Ashmanskas, B
    Maruyama, T
    Zimmerman, T
    Moccia, S
    Lewis, J
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 518 (1-2) : 277 - 280
  • [3] *CDF COLL, FERMILABPUB96390E
  • [4] The SVX3D integrated circuit for dead-timeless silicon strip readout
    Garcia-Sciveres, M
    Milgrome, O
    Zimmerman, T
    Volobouev, I
    Ely, RP
    Connolly, A
    Fish, D
    Affolder, T
    Sill, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 435 (1-2) : 58 - 64
  • [5] Life expectancy of the CDF Run II silicon
    Worm, S
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 549 (1-3) : 126 - 129