Assessment of cortical bone with clinical and ultrashort echo time sequences

被引:61
|
作者
Du, Jiang [1 ]
Hermida, Juan C. [2 ]
Diaz, Eric [1 ]
Corbeil, Jacqueline [1 ]
Znamirowski, Richard [1 ]
D'Lima, Darryl D. [2 ]
Bydder, Graeme M. [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[2] Scripps Res Inst, Dept Mol & Expt Med, La Jolla, CA 92037 USA
关键词
ultrashort echo time; projection reconstruction; adiabatic inversion; cortical bone; free water; bound water; SPECTROSCOPIC IMAGING UTESI; RF EXCITATION; BOUND WATER; MRI; CONTRAST; POROSITY; DENSITY; MATRIX; SIGNAL; PORE;
D O I
10.1002/mrm.24497
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We describe the use of ultrashort echo time (UTE) sequences and fast spin echo sequences to assess cortical bone using a clinical 3T scanner. Regular two- and three-dimensional UTE sequences were used to image both bound and free water in cortical bone. Adiabatic inversion recovery prepared UTE sequences were used to image water bound to the organic matrix. Two-dimensional fast spin echo sequences were used to image free water. Regular UTE sequences were used together with bicomponent analysis to measure T*(2)s and relative fractions of bound and free water components in cortical bone. Inversion recovery prepared UTE sequences were used to measure the T*(2) of bound water. Saturation recovery UTE sequences were used to measure the T-1 of bone water. Eight cadaveric human cortical bone samples and a lower leg specimen were studied. Preliminary results show two distinct components in UTE detected signal decay, a single component in inversion recovery prepared UTE detected signal decay, and a single component in saturation recovery UTE detected signal recovery. Regular UTE sequences appear to depict both bound and free water in cortical bone. Inversion recovery prepared UTE sequences appear to depict water bound to the organic matrix. Two-dimensional fast spin echo sequences appear to depict bone structure corresponding to free water in large pores. Magn Reson Med 70:697-704, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:697 / 704
页数:8
相关论文
共 50 条
  • [31] Comparison of Ultrashort Echo Time Sequences for MRI of an Ancient Mummified Human Hand
    Oezen, Ali Caglar
    Ludwig, Ute
    Oehrstroem, Lena Maria
    Ruehli, Frank Jakobus
    Bock, Michael
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (02) : 701 - 708
  • [32] Evaluation of ultrashort echo-time (UTE) and fast-field-echo (FRACTURE) sequences for skull bone visualization and fracture detection - A postmortem study
    Deininger-Czermak, Eva
    Euler, Andre
    Franckenberg, Sabine
    Finkenstaedt, Tim
    Villefort, Christina
    Gascho, Dominic
    Guggenberger, Roman
    JOURNAL OF NEURORADIOLOGY, 2022, 49 (03) : 237 - 243
  • [33] Science to practice: In vivo quantification of cortical bone water with ultrashort echo-time MR imaging: A new parameter to measure bone quality?
    Link, Thomas M.
    RADIOLOGY, 2008, 248 (03) : 705 - 706
  • [34] Impact of acceleration on bone depiction quality by ultrashort echo time magnetic resonance bone imaging sequences in medication-related osteonecrosis of the jaw
    Getzmann, Jonas M.
    Huber, Florian A.
    Nakhostin, Dominik
    Deininger-Czermak, Eva
    Schumann, Paul
    Finkenstaedt, Tim
    Del Grande, Filippo
    Guggenberger, Roman
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2022, 9
  • [35] Assessment of lung density in pediatric patients using three-dimensional ultrashort echo-time and four-dimensional zero echo-time sequences
    Konstantinos G. Zeimpekis
    Christian J. Kellenberger
    Julia Geiger
    Japanese Journal of Radiology, 2022, 40 : 722 - 729
  • [36] Assessment of lung density in pediatric patients using three-dimensional ultrashort echo-time and four-dimensional zero echo-time sequences
    Zeimpekis, Konstantinos G.
    Kellenberger, Christian J.
    Geiger, Julia
    JAPANESE JOURNAL OF RADIOLOGY, 2022, 40 (07) : 722 - 729
  • [37] Mineralization in calcified plaque is like that of cortical bone-Further evidence from ultrashort echo time (UTE) magnetic resonance imaging of carotid plaque calcification and cortical bone
    Du, Jiang
    Peterson, Michael
    Kansal, Nikhil
    Bydder, Graeme M.
    Kahn, Andrew
    MEDICAL PHYSICS, 2013, 40 (10)
  • [38] Comparison of lung imaging using three-dimensional ultrashort echo time and zero echo time sequences: preliminary study
    Kyungsoo Bae
    Kyung Nyeo Jeon
    Moon Jung Hwang
    Joon Sung Lee
    Ji Young Ha
    Kyeong Hwa Ryu
    Ho Cheol Kim
    European Radiology, 2019, 29 : 2253 - 2262
  • [39] Comparison of lung imaging using three-dimensional ultrashort echo time and zero echo time sequences: preliminary study
    Bae, Kyungsoo
    Jeon, Kyung Nyeo
    Hwang, Moon Jung
    Lee, Joon Sung
    Ha, Ji Young
    Ryu, Kyeong Hwa
    Kim, Ho Cheol
    EUROPEAN RADIOLOGY, 2019, 29 (05) : 2253 - 2262
  • [40] Quantifying Temperature-Dependent T1 Changes in Cortical Bone Using Ultrashort Echo-Time MRI
    Han, Misung
    Rieke, Viola
    Scott, Serena J.
    Ozhinsky, Eugene
    Salgaonkar, Vasant A.
    Jones, Peter D.
    Larson, Peder E. Z.
    Diederich, Chris J.
    Krug, Roland
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (06) : 1548 - 1555