Assessment of cortical bone with clinical and ultrashort echo time sequences

被引:61
作者
Du, Jiang [1 ]
Hermida, Juan C. [2 ]
Diaz, Eric [1 ]
Corbeil, Jacqueline [1 ]
Znamirowski, Richard [1 ]
D'Lima, Darryl D. [2 ]
Bydder, Graeme M. [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[2] Scripps Res Inst, Dept Mol & Expt Med, La Jolla, CA 92037 USA
关键词
ultrashort echo time; projection reconstruction; adiabatic inversion; cortical bone; free water; bound water; SPECTROSCOPIC IMAGING UTESI; RF EXCITATION; BOUND WATER; MRI; CONTRAST; POROSITY; DENSITY; MATRIX; SIGNAL; PORE;
D O I
10.1002/mrm.24497
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We describe the use of ultrashort echo time (UTE) sequences and fast spin echo sequences to assess cortical bone using a clinical 3T scanner. Regular two- and three-dimensional UTE sequences were used to image both bound and free water in cortical bone. Adiabatic inversion recovery prepared UTE sequences were used to image water bound to the organic matrix. Two-dimensional fast spin echo sequences were used to image free water. Regular UTE sequences were used together with bicomponent analysis to measure T*(2)s and relative fractions of bound and free water components in cortical bone. Inversion recovery prepared UTE sequences were used to measure the T*(2) of bound water. Saturation recovery UTE sequences were used to measure the T-1 of bone water. Eight cadaveric human cortical bone samples and a lower leg specimen were studied. Preliminary results show two distinct components in UTE detected signal decay, a single component in inversion recovery prepared UTE detected signal decay, and a single component in saturation recovery UTE detected signal recovery. Regular UTE sequences appear to depict both bound and free water in cortical bone. Inversion recovery prepared UTE sequences appear to depict water bound to the organic matrix. Two-dimensional fast spin echo sequences appear to depict bone structure corresponding to free water in large pores. Magn Reson Med 70:697-704, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:697 / 704
页数:8
相关论文
共 26 条
  • [1] Quantitative Ultrashort Echo Time (UTE) MRI of Human Cortical Bone: Correlation With Porosity and Biomechanical Properties
    Bae, Won C.
    Chen, Peter C.
    Chung, Christine B.
    Masuda, Koichi
    D'Lima, Darryl
    Du, Jiang
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2012, 27 (04) : 848 - 857
  • [2] Regional differences in cortical porosity in the fractured femoral neck
    Bell, KL
    Loveridge, N
    Power, J
    Garrahan, N
    Meggitt, BF
    Reeve, J
    [J]. BONE, 1999, 24 (01) : 57 - 64
  • [3] Ultrashort echo time (UTE) imaging with bi-component analysis: Bound and free water evaluation of bovine cortical bone subject to sequential drying
    Biswas, Reni
    Bae, Won
    Diaz, Eric
    Masuda, Koichi
    Chung, Christine B.
    Bydder, Graeme M.
    Du, Jiang
    [J]. BONE, 2012, 50 (03) : 749 - 755
  • [4] Quantitative Bone Matrix Density Measurement by Water- and Fat-Suppressed Proton Projection MRI (WASPI) With Polymer Calibration Phantoms
    Cao, Haihui
    Ackerman, Jerome L.
    Hrovat, Mirko I.
    Graham, Lila
    Glimcher, Melvin J.
    Wu, Yaotang
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (06) : 1433 - 1443
  • [5] Optimization of RF Excitation to Maximize Signal and T2 Contrast of Tissues With Rapid Transverse Relaxation
    Carl, Michael
    Bydder, Mark
    Du, Jiang
    Takahashi, Atsushi
    Han, Eric
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (02) : 481 - 490
  • [6] Crock HV, 1996, ATLAS VASCULAR ANATO, P270
  • [7] Ultrashort echo time spectroscopic imaging (UTESI): an efficient method for quantifying bound and free water
    Diaz, Eric
    Chung, Christine B.
    Bae, Won C.
    Statum, Sheronda
    Znamirowski, Richard
    Bydder, Graeme M.
    Du, Jiang
    [J]. NMR IN BIOMEDICINE, 2012, 25 (01) : 161 - 168
  • [8] Du J, 2009, INT SOC MAGN RES MED
  • [9] Ultrashort echo time spectroscopic imaging (UTESI) of cortical bone
    Du, Jiang
    Hamilton, Gavin
    Takahashi, Atsushi
    Bydder, Mark
    Chung, Christine B.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (05) : 1001 - 1009
  • [10] Ultrashort echo time imaging with bicomponent analysis
    Du, Jiang
    Diaz, Eric
    Carl, Michael
    Bae, Won
    Chung, Christine B.
    Bydder, Graeme M.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (03) : 645 - 649