A Base-Sequence-Modulated Golay Code Improves the Excitation and Measurement of Ultrasonic Guided Waves in Long Bones

被引:22
作者
Song, Xiaojun [1 ]
Ta, Dean [1 ]
Wang, Weiqi [1 ]
机构
[1] Fudan Univ, Dept Elect Engn, Shanghai 200433, Peoples R China
基金
中国国家自然科学基金;
关键词
SYSTEM;
D O I
10.1109/TUFFC.2012.2492
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Researchers are interested in using ultrasonic guided waves (GWs) to assess long bones. However, GWs suffer high attenuation when they propagate in long bones, resulting in a low SNR. To overcome this limitation, this paper introduces a base-sequence-modulated Golay code (BSGC) to produce larger amplitude and improve the SNR in the ultrasound evaluation of long bones. A 16-bit Golay code was used for excitation in computer simulation. The decoded GWs and the traditional GWs, which were generated by a single pulse, agreed well after decoding the received signals, and the SNR was improved by 26.12 dB. In the experiments using bovine bones, the BSGC excitation produced the amplitudes which were at least 237 times greater than those produced by a single pulse excitation. The BSGC excitation also allowed the GWs to be received over a longer distance between two transducers. The results suggest the BSGC excitation has the potential to measure GWs and assess long bones.
引用
收藏
页码:2580 / 2583
页数:4
相关论文
共 13 条
  • [1] Coded excitation for diagnostic ultrasound: A system developer's perspective
    Chiao, RY
    Hao, XH
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (02) : 160 - 170
  • [2] Application of Golay codes to improve the dynamic range in ultrasonic Lamb waves air-coupled systems
    Garcia-Rodriguez, M.
    Yanez, Y.
    Garcia-Hernandez, M. J.
    Salazar, J.
    Turo, A.
    Chavez, J. A.
    [J]. NDT & E INTERNATIONAL, 2010, 43 (08) : 677 - 686
  • [3] GOLAY MJE, 1961, IRE T INFORM THEOR, V7, P82, DOI 10.1109/TIT.1961.1057620
  • [4] Guided wave phase velocity measurement using multi-emitter and multi-receiver arrays in the axial transmission configuration
    Minonzio, Jean-Gabriel
    Talmant, Marilyne
    Laugier, Pascal
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2010, 127 (05) : 2913 - 2919
  • [5] Modeling the impact of soft tissue on axial transmission measurements of ultrasonic guided waves in human radius
    Moilanen, Petro
    Talmant, Maryline
    Kilappa, Vantte
    Nicholson, Patrick
    Cheng, Sulin
    Timonen, Jussi
    Laugier, Pascal
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2008, 124 (04) : 2364 - 2373
  • [6] Influence of the ultrasound transducer bandwidth on selection of the complementary Golay bit code length
    Nowicki, A.
    Trots, I.
    Lewin, P. A.
    Secomski, W.
    Tymkiewicz, R.
    [J]. ULTRASONICS, 2007, 47 (1-4) : 64 - 73
  • [7] High-Resolution Ultrasound Displacement Measurement Using Coded Excitations
    Peng, Qiyu
    Zhang, Li-Qun
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2011, 58 (01) : 122 - 133
  • [8] ANALYSIS OF SUPERIMPOSED ULTRASONIC GUIDED WAVES IN LONG BONES BY THE JOINT APPROXIMATE DIAGONALIZATION OF EIGEN-MATRICES ALGORITHM
    Song, Xiaojun
    Ta, Dean
    Wang, Weiqi
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (10) : 1704 - 1713
  • [9] Identification and analysis of multimode guided waves in tibia cortical bone
    Ta, De-an
    Huang, Kai
    Wang, Wei-qi
    Wang, Yuan-yuan
    Le, Lawrence H.
    [J]. ULTRASONICS, 2006, 44 : E279 - E284
  • [10] MEASUREMENT OF THE DISPERSION AND ATTENUATION OF CYLINDRICAL ULTRASONIC GUIDED WAVES IN LONG BONE
    Ta, Dean
    Wang, Weiqi
    Wang, YuanYuan
    Le, Lawrence H.
    Zhou, Yuqing
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2009, 35 (04) : 641 - 652