Current and Potential Applications of Anterior Segment Optical Coherence Tomography in Contact Lens Fitting

被引:7
作者
Luo, Zhonghui K. [2 ]
Jacobs, Deborah S. [1 ,2 ]
机构
[1] Boston Fdn Sight, Needham, MA 02494 USA
[2] Harvard Univ, Massachusetts Eye & Ear Infirm, Sch Med, Boston, MA USA
关键词
Anterior segment OCT; Topography; Scleral lens; Contact lens; Ocular surface; DOMAIN MODE-LOCKING; VERSUS-HOST-DISEASE; BOSTON SCLERAL LENS; SWEPT SOURCE OCT; CORNEAL TOPOGRAPHY; IN-VIVO; LASER; EYE; GLAUCOMA; REFLECTOMETRY;
D O I
10.3109/08820538.2012.708814
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Optical coherence tomography (OCT) is a non-invasive, high-resolution and high-speed imaging modality that has enjoyed rapid growth in ophthalmology since its development 20 years ago. Contact lens fitting is traditionally based on trial lenses, which is expensive and time-consuming. Modern anterior segment OCT is capable of generating three-dimensional ocular surface maps of the cornea and sclera with potential application in contact lens fitting. This paper reviewed the history, the ophthalmic applications, and the most recent advancement in three-dimensional anterior segment OCT. There is very limited literature of OCT in contact lens fitting to date. This review anticipates an increase in this application in the near future.
引用
收藏
页码:133 / 137
页数:5
相关论文
共 59 条
[1]   Swept source optical coherence tomography using an all-fiber 1300-nm ring laser source [J].
Choma, MA ;
Hsu, K ;
Izatt, JA .
JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (04)
[2]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[3]   State-of-the-art retinal optical coherence tomography [J].
Drexler, Wolfgang ;
Fujimoto, James G. .
PROGRESS IN RETINAL AND EYE RESEARCH, 2008, 27 (01) :45-88
[4]   Confocal Microscopy in Ophthalmology [J].
Erie, Jay C. ;
McLaren, Jay W. ;
Patel, Sanjay V. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (05) :639-646
[5]   EYE-LENGTH MEASUREMENT BY INTERFEROMETRY WITH PARTIALLY COHERENT-LIGHT [J].
FERCHER, AF ;
MENGEDOHT, K ;
WERNER, W .
OPTICS LETTERS, 1988, 13 (03) :186-188
[6]   Retinal optical coherence tomography: past, present and future perspectives [J].
Geitzenauer, Wolfgang ;
Hitzenberger, Christoph K. ;
Schmidt-Erfurth, Ursula M. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (02) :171-177
[7]   A novel method of fitting scleral high resolution optical coherence lenses using tomography [J].
Gemoules, Greg .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2008, 34 (02) :80-83
[8]   Ultra high-speed swept source OCT imaging of the anterior segment of human eye at 200 kHz with adjustable imaging range [J].
Gora, Michalina ;
Karnowski, Karol ;
Szkulmowski, Maciej ;
Kaluzny, Bartlomiej J. ;
Huber, Robert ;
Kowalczyk, Andrzej ;
Wojtkowski, Maciej .
OPTICS EXPRESS, 2009, 17 (17) :14880-14894
[9]   The Boston Scleral Lens in the treatment of pediatric patients [J].
Gungor, Inci ;
Schor, Kenneth ;
Rosenthal, Perry ;
Jacobs, Deborah S. .
JOURNAL OF AAPOS, 2008, 12 (03) :263-267
[10]   The Influence of Corneoscleral Topography on Soft Contact Lens Fit [J].
Hall, Lee A. ;
Young, Graeme ;
Wolffsohn, James S. ;
Riley, Colleen .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (09) :6801-6806