We developed a novel resection device to use during transapical transcatheter aortic valve implantation (TAVI) using a circular blade. We assessed the device in 15 human cadavers by transapical approach. After the resection, the aortic annulus was measured using standard probes. A careful examination of the aortic wall, left ventricular outflow tract, coronary ostia and mitral valve was performed using an endpoint checklist, developed specifically for the new device. The resection was successfully completed in 14 out of 15 (93%) cases. All the resected leaflets and debris have been successfully evaluated in 15 out of 15 (100%) cases. One case of a bicuspid valve had a prominent calcification of the median raphe. The resection tool could only perform a partial resection. The mean duration of the resection was 45 +/- 30 s. The surrounding tissue examination did not reveal any injury to the anatomical structures. Endovascular resection of the native valve using transapical approach is feasible and effective. Further developments are necessary before the definitive clinical use during percutaneous aortic valve implantation.
引用
收藏
页码:378 / 380
页数:3
相关论文
共 50 条
  • [31] Percutaneous endoscopic transapical aortic valve implantation: three experimental transcatheter models
    Chu, Michael W. A.
    Falk, Volkmar
    Mohr, Friedrich W.
    Walther, Thomas
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2011, 13 (03) : 251 - 256
  • [32] Transapical transcatheter aortic valve implantation: Follow-up to 3 years
    Ye, Jian
    Cheung, Anson
    Lichtenstein, Samuel V.
    Nietlispach, Fabian
    Albugami, Saad
    Masson, Jean-Bernard
    Thompson, Christopher R.
    Munt, Brad
    Moss, Robert
    Carere, Ronald G.
    Jamieson, W. R. Eric
    Webb, John G.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (05) : 1107 - U27
  • [33] Transcatheter aortic valve implantation for the treatment of pure aortic valve insufficiency
    Casenghi, Matteo
    Poletti, Enrico
    Rubbio, Antonio Popolo
    Brambilla, Nedy
    Testa, Luca
    Bedogni, Francesco
    De Marco, Federico
    GIORNALE ITALIANO DI CARDIOLOGIA, 2021, 22 (09) : 21S - 28S
  • [34] Transcatheter Aortic Valve Implantation for Bioprosthetic Valve Failure: Placement of Aortic Transcatheter Valves 3 Aortic Valve-in-Valve Study
    Malaisrie, S. Chris
    Zajarias, Alan
    Leon, Martin B.
    Mack, Michael J.
    Pibarot, Philippe
    Hahn, Rebecca T.
    Brown, David
    Wong, S. Chiu
    Oldemeyer, J. Bradley
    Shang, Kan
    Leipsic, Jonathon
    Blanke, Philipp
    Guerrero, Mayra
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2022, 6 (06):
  • [35] Transapical transcatheter aortic valve replacement with a novel transcatheter aortic valve replacement system in high-risk patients with severe aortic valve diseases
    Zhu, Liming
    Guo, Yingqiang
    Wang, Wei
    Liu, Huan
    Yang, Ye
    Wei, Lai
    Wang, Chunsheng
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 155 (02) : 588 - 597
  • [36] Results of percutaneous and transapical transcatheter aortic valve implantation performed by a surgical team
    Bleiziffer, Sabine
    Ruge, Hendrik
    Mazzitelli, Domenico
    Schreiber, Christian
    Hutter, Andrea
    Laborde, Jean-Claude
    Bauernschmitt, Robert
    Lange, Ruediger
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2009, 35 (04) : 615 - 621
  • [37] Twelve-month outcomes of transapical transcatheter aortic valve implantation in patients with severe aortic valve stenosis
    Wiewiorka, Lukasz
    Sobczynski, Robert
    Trebacz, Jaroslaw
    Sadowski, Jerzy
    Dudek, Dariusz
    Stapor, Maciej
    Konstanty-Kalandyk, Janusz
    Musial, Robert
    Gackowski, Andrzej
    Malinowski, Krzystof
    Kleczynski, Pawel
    Zmudka, Krzysztof
    Kapelak, Boguslaw
    Legutko, Jacek
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2021, 17 (01): : 68 - 74
  • [38] Outcomes After Transcatheter Aortic Valve Implantation: Transfemoral Versus Transapical Approach
    Ewe, See Hooi
    Delgado, Victoria
    Ng, Arnold C. T.
    Antoni, M. Louisa
    van der Kley, Frank
    Marsan, Nina Ajmone
    de Weger, Arend
    Tavilla, Giuseppe
    Holman, Eduard R.
    Schalij, Martin J.
    Bax, Jeroen J.
    ANNALS OF THORACIC SURGERY, 2011, 92 (04) : 1244 - 1251
  • [39] Transapical Transcatheter Aortic Valve for Severe Aortic Regurgitation Expanding the Limits
    Wendt, Daniel
    Kahlert, Philipp
    Pasa, Susanne
    El-Chilali, Karim
    Al-Rashid, Fadi
    Tsagakis, Konstantinos
    Dohle, Daniel Sebastian
    Erbel, Raimund
    Jakob, Heinz
    Thielmann, Matthias
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (10) : 1159 - 1167
  • [40] The influence of native aortic valve calcium and transcatheter valve oversize on the need for pacemaker implantation after transcatheter aortic valve insertion
    Al-Azzam, Fu'ad
    Greason, Kevin L.
    Krittanawong, Chayakrit
    Williamson, Eric E.
    McLeod, Christopher J.
    King, Katherine S.
    Mathew, Verghese
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 153 (05) : 1056 - +