SIFT-MS Analysis of Nose-Exhaled Breath; Mouth Contamination and the Influence of Exercise

被引:19
|
作者
Smith, David [1 ]
Chippendale, Thomas W. E. [1 ]
Dryahina, Kseniya [2 ]
Spanel, Patrik [2 ]
机构
[1] Keele Univ, Inst Sci & Technol Med, Sch Med, Stoke On Trent ST4 7QB, Staffs, England
[2] Acad Sci Czech Republ, J Heyrovsky Inst Phys Chem, CR-18223 Prague 8, Czech Republic
关键词
Selected ion flow tube mass spectrometry; breath analysis; nose exhalation; volatile organic compounds; TUBE MASS-SPECTROMETRY; VOLATILE ORGANIC-COMPOUNDS; PSEUDOMONAS-AERUGINOSA; QUANTITATIVE-ANALYSIS; TRACE GASES; HUMID AIR; QUANTIFICATION; ISOPRENE; AMMONIA; VOLUNTEERS;
D O I
10.2174/15734110113099990021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The value of selected ion flow tube mass spectrometry, SIFT-MS, for the sampling and analysis of trace metabolites in both mouth-exhaled and nose-exhaled breath is discussed, and the latter is shown to circumvent oral contamination. Results of experiments are described in which increased levels of ammonia and ethanol deliberately generated in the oral cavity are clearly registered in mouth-exhaled breath but not in nose-exhaled breath. The value of the sampling methods that are used for the analysis of trace metabolites in both mouth-exhaled and nose-exhaled breath with selected ion flow tube mass spectrometry, SIFT-MS, is discussed, and their importance as a means to provide concentrations of truly endogenous compounds by circumventing their oral contamination is demonstrated. Further to this, data are presented on the direct analysis by SIFT-MS of several compounds in the nose-exhaled breath of eight healthy volunteers during exercise on a stationary bicycle. Of note are the data on breath isoprene, which is seen to increase during exercise above the respective resting levels for all eight volunteers by a factor of 2 or 3 times, this being in accordance with previous observations. Taken together, the results of this study show the value and simplicity of direct analysis of nose-exhaled breath by SIFT-MS, which can provide immediate results to the clinician and sports physiologists with no pain or discomfort to the volunteer or patient.
引用
收藏
页码:565 / 575
页数:11
相关论文
共 50 条
  • [21] A longitudinal study of methanol in the exhaled breath of 30 healthy volunteers using selected ion flow tube mass spectrometry, SIFT-MS
    Turner, Claire
    Spanel, Patrik
    Smith, David
    PHYSIOLOGICAL MEASUREMENT, 2006, 27 (07) : 637 - 648
  • [22] Breath Analysis Using SIFT-MS to Assess Metabolic Status in Patients After Gastro-oesophageal Cancer Surgery- a Pilot Study
    Huang, Juzheng
    Kumar, Sacheen
    Boshier, Piers R.
    Wakefield, Stephanie
    Cushnir, Julia R.
    Hanna, George B.
    CURRENT ANALYTICAL CHEMISTRY, 2013, 9 (04) : 584 - 592
  • [23] Online, real-time, and direct use of SIFT-MS to measure garlic breath deodorization: a review
    Castada, Hardy Z.
    Barringer, Sheryl Ann
    FLAVOUR AND FRAGRANCE JOURNAL, 2019, 34 (05) : 299 - 306
  • [24] Influence of weakly bound adduct ions on breath trace gas analysis by selected ion flow tube mass spectrometry (SIFT-MS)
    Spanel, Patrik
    Smith, David
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2009, 280 (1-3) : 128 - 135
  • [25] Use of a least absolute shrinkage and selection operator (LASSO) model to selected ion flow tube mass spectrometry (SIFT-MS) analysis of exhaled breath to predict the efficacy of dialysis: a pilot study
    Wang, Maggie Haitian
    Chong, Ka Chun
    Storer, Malina
    Pickering, John W.
    Endre, Zoltan H.
    Lau, Steven Y. F.
    Kwok, Chloe
    Lai, Maria
    Chung, Hau Yin
    Zee, Benny Chung Ying
    JOURNAL OF BREATH RESEARCH, 2016, 10 (04)
  • [26] Isoprene levels in the exhaled breath of 200 healthy pupils within the age range 7-18 years studied using SIFT-MS
    Smith, David
    Spanel, Patrik
    Enderby, Beth
    Lenney, Warren
    Turner, Claire
    Davies, Simon J.
    JOURNAL OF BREATH RESEARCH, 2010, 4 (01)
  • [27] Non-invasive prediction of lung cancer histological types through exhaled breath analysis by UV-irradiated electronic nose and GC/QTOF/MS
    Saidi, Tarik
    Moufid, Mohammed
    de Jesus Beleno-Saenz, Kelvin
    Geremariam Welearegay, Tesfalem
    El Bari, Nezha
    Lisset Jaimes-Mogollon, Aylen
    Ionescu, Radu
    Bourkadi, Jamal Eddine
    Benamor, Jouda
    El Ftouh, Mustapha
    Bouchikhi, Benachir
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 311
  • [28] Exhaled Breath Analysis Using a Novel Electronic Nose for Different Respiratory Disease Entities
    Yu, Kai-Lun
    Yang, Han-Ching
    Lee, Chien-Feng
    Wu, Shang-Yu
    Ye, Zhong-Kai
    Rai, Sujeet Kumar
    Lee, Meng-Rui
    Tang, Kea-Tiong
    Wang, Jann-Yuan
    LUNG, 2025, 203 (01)
  • [29] Generation of volatile compounds on mouth exposure to urea and sucrose: implications for exhaled breath analysis
    Spanel, P
    Turner, C
    Wang, TS
    Bloor, R
    Smith, D
    PHYSIOLOGICAL MEASUREMENT, 2006, 27 (02) : N7 - N17
  • [30] A longitudinal study of breath isoprene in healthy volunteers using selected ion flow tube mass spectrometry (SIFT-MS)
    Turner, C
    Spanel, P
    Smith, D
    PHYSIOLOGICAL MEASUREMENT, 2006, 27 (01) : 13 - 22