Experimental evaluation of VOC removal efficiency of a coconut shell activated carbon filter for indoor air quality enhancement

被引:80
作者
Gallego, E. [1 ]
Roca, F. J. [1 ]
Perales, J. F. [1 ]
Guardino, X. [2 ]
机构
[1] LCMA UPC, Avda Diagonal 647, E-08028 Barcelona, Spain
[2] INSHT, Ctr Nacl Condic Trabajo, E-08034 Barcelona, Spain
关键词
Volatile organic compounds; Activated carbon filters; Thermal desorption; Gas chromatography/mass spectrometry; Ozone; Indoor air quality; VOLATILE ORGANIC-COMPOUNDS; ADSORPTION; OZONE; ODOR; ENVIRONMENTS; PERFORMANCE; POLLUTANTS; OXIDATION; EXPOSURE; TOLUENE;
D O I
10.1016/j.buildenv.2013.05.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The present study evaluated the performance of a commercially available activated carbon filter for VOC removal from air through the analysis of real samples. The filter was tested for VOC reduction efficiencies in a PVC portable inflatable bubble provided with an air purifier system called Airbox II Phase by Zonair3d, as described hereinafter. The filter was placed in the Airbox II Phase of the bubble, between a pre-filter and a particulate HEPA H14 filter. Simultaneous duplicate samples were taken from the input air duct before the driving system and from the bubble. VOC were dynamically sampled during 2-h control periods by connecting custom packed glass multi-sorbent cartridge tubes (Carbotrap, Carbopack X and Carboxen 569) to air pump samplers. A validated analytical method based on TD-GC/MS was used to quantify a wide variety of VOC families (alkanes, aromatic hydrocarbons, alcohols, ketones, halocarbons, aldehydes, esters, terpenes, ethers, glycols and nitrogenated compounds). VOC family removal efficiencies ranged from 51 +/- 19% to 78 +/- 22% with input indoor air, and from 42 +/- 16% to 91 +/- 18% with input outdoor air. No significant differences in reduction efficiencies (t-test; p < 0.05) were observed between using indoor or outdoor air. Several aldehydes were desorbed from the filter at low concentrations (0.09-21.19 mu g m(-3)) when outdoor air was used as input air. Ozone removal efficiency was assessed by a continuous monitoring system. A 100% yield was obtained in all cases where ozone was present. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:14 / 25
页数:12
相关论文
共 52 条
[1]   Personal exposure of children to air pollution [J].
Ashmore, M. R. ;
Dimitroulopoulou, C. .
ATMOSPHERIC ENVIRONMENT, 2009, 43 (01) :128-141
[2]   Assessing the performance of air cleaning devices - A full-scale test method [J].
Bastani, Arash ;
Lee, Chang-Seo ;
Haghighat, Fariborz ;
Flaherty, Chris ;
Lakdawala, Ness .
BUILDING AND ENVIRONMENT, 2010, 45 (01) :143-149
[3]   The health effects of nonindustrial indoor air pollution [J].
Bernstein, Jonathan A. ;
Alexis, Neil ;
Bacchus, Hyacinth ;
Bernstein, I. Leonard ;
Fritz, Pat ;
Horner, Elliot ;
Li, Ning ;
Mason, Stephany ;
Nel, Andre ;
Oullette, John ;
Reijula, Kari ;
Reponen, Tina ;
Seltzer, James ;
Smith, Alisa ;
Tarlo, Susan M. .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2008, 121 (03) :585-591
[4]   Indoor Air Contaminants and their Impact on Respiratory Pathologies [J].
Carazo Fernandez, Luis ;
Fernandez Alvarez, Ramon ;
Javier Gonzalez-Barcala, Francisco ;
Rodriguez Portal, Jose Antonio .
ARCHIVOS DE BRONCONEUMOLOGIA, 2013, 49 (01) :22-27
[5]   Assessment of the impact of the vehicular traffic on BTEX concentration in ring roads in urban areas of Bari (Italy) [J].
Caselli, Maurizio ;
de Gennaro, Gianluigi ;
Marzocca, Annalisa ;
Trizio, Livia ;
Tutino, Maria .
CHEMOSPHERE, 2010, 81 (03) :306-311
[6]   Barriers and opportunities for passive removal of indoor ozone [J].
Gall, Elliott T. ;
Corsi, Richard L. ;
Siegel, Jeffrey A. .
ATMOSPHERIC ENVIRONMENT, 2011, 45 (19) :3338-3341
[7]   Indoor and outdoor BTX levels in Barcelona City metropolitan area and Catalan rural areas [J].
Gallego, E. ;
Roca, F. X. ;
Guardino, X. ;
Rosell, M. G. .
JOURNAL OF ENVIRONMENTAL SCIENCES, 2008, 20 (09) :1063-1069
[8]  
Gallego E, 2011, SICK BUILDING SYNDROME IN PUBLIC BUILDINGS AND WORKPLACES, P289, DOI 10.1007/978-3-642-17919-8_16
[9]   Determining indoor air quality and identifying the origin of odour episodes in indoor environments [J].
Gallego, Eva ;
Roca, Xavier ;
Francisco Perales, Jose ;
Guardino, Xavier .
JOURNAL OF ENVIRONMENTAL SCIENCES, 2009, 21 (03) :333-339
[10]   Photocatalytic degradation of organic paint constituents-formation of carbonyls [J].
Geiss, Otmar ;
Cacho, Carmen ;
Barrero-Moreno, Josefa ;
Kotzias, Dimitrios .
BUILDING AND ENVIRONMENT, 2012, 48 :107-112